ANGNI 10G Homogenizer Processing capacity 30~250ml
The ANGNI 10G homogenizer head is the optional head of the AD145S-P ultra-fine homogenizer, with a diameter of 10mm and a suitable viscosity of 200cp. The overall length of the 10G homogenizer head is 178mm, and the rotor line speed is up to 13m/s.
AN-
MUXUAN MXR-22-3 Three-stage emulsification pump line type high shear homogeneous Mulser
$ 4906.00 -
Huxi HR-90Z Pilot High-Shear Dispersing Emulsifier with 90T3 working head
$ 6751.00 -
HUXI HR-500D/10G High Shear Dispersion Mulser 10-150ml /200cp
$ 1608.00 -
HUXI HR500-25T1 Digital Display High Shear Dispersion Mulser 8000cp/7000ml
$ 1608.00 -
Huxi HR-90Z Pilot High-Shear Dispersing Emulsifier with 90G working head
$ 6556.00
Oni 10G homogenizer is an optional working head for the AD145S-P ultra-fine homogenizer, with a diameter of 10mm, a viscosity of 200cp, an overall length of 10G homogenizing head of 178mm, and a rotor linear speed of 13m/s.
Homogenization head selection table
| specification | Throughput | Maximum viscosity | Maximum linear speed | Minimum/maximum immersion liquid length | Head length | Maximum temperature | Contact material material |
| 6G | 0.2-10 ml | 100 cP | 8 m/s | 18/60mm | 125mm | 120 ℃ | SS316L、PTFE |
| 8G | 1-60 ml | 100 cP | 10 m/s | 20/85mm | 148mm | 120 ℃ | SS316L、PTFE |
| 10G | 30-250 ml | 200 cP | 13 m/s | 20/110mm | 178mm | 120 ℃ | SS316L、PTFE |
AN 10G Homogenizing headSpecifications
| LIST | VALUE |
|---|---|
| Processing Capacity | 30~250mL |
| Rotor maximum linear velocity | 13m/s |
| Work head specification | Φ10mm |
| Work head material | SS316 |
| Max. Processing Viscosity | 200mPa·s |
| Applicable maximum temperature | 120℃ |
| overall length | 178mm |
| Bearing material | PTFE |
| Minimum immersion liquid height | 20mm |
| Maximum immersion liquid height | 110mm |
AN 10G Homogenizing head Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- MIL-STD810G test standard
- HANNA HI96821 Digital refractometer operation guide
- Classification and Application of Formula Guide
- Lab Film Applicators for prepative polypropylene (PP) nitrile films
- Selection guide for Surface Tensiometers
- Critical surface tension and its role in pigment wettability
- Demonstration of RCA wear-resistant tape machine
- Difference Between Halogen Moisture Analyzer and Thermogravimeter
- Calibration Terms - Coating Thickness Gages
- Application and test method of UV accelerated weathering Test Chamber in automotive Glass film


10G