Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> JENCO> JENCO 6308DT Dissolved oxygen (DO) temperature controller
      JENCO 6308DT Dissolved oxygen (DO) temperature controller

      JENCO 6308DT on-line dissolved oxygen (DO) temperature controller

      DO (0~40.00ppm), 4~ 20mA reversible isolated output, five sets of relay control, RS-485 interface

      Brand
      SKU: NB002956
      United States JENCO
      Model
      VS
      Genuinegoods
      • JENCO 6308DT Dissolved oxygen (DO) temperature controllerOverview

      • Specifications
      • Comments
      • FAQs
      6308DT
      Dissolved oxygen (DO) temperature controller
      • JENCO 6308DT on-line dissolved oxygen (DO) temperature controller
      DO (0~40.00ppm), 4~ 20mA reversible isolated output, five sets of relay control, RS-485 interface

      Introduction

      • Standard 1/4 DIN waterproof body design

      • 128x64 dot matrix backlit LCD display, can display pH value, temperature value at the same time

      • Polarographic dissolved oxygen sensor is used

      • 4~20mA reversible, with isolated current output, the output range can be set by the user

      • Three sets of pH relay control/one set of temperature relay control, the control point/hysteresis width can be set by the user

      • It has the function of automatic temperature compensation

      • Power-off correction value memory function

      • RS-485 communication interface is adopted

      • The products have passed CE certification

        JENCO 6308DT In-Line Dissolved Oxygen (DO) Temperature Controller

      6308DT Industrial In-Line Dissolved Oxygen (DO) Temperature Controller Optional Accessory


      ModelIntroduction
      electrodeOXYSENS 120Sewage and aquaculture fields
      OXYFERM 120High-temperature fermentation system
      cableOXYFERM 120 special cable3m/5m/10m/15m line length
      Sheath tube009B1 meter tube length
      Special sheath for OXYFERM 120
      The electrodes are seatedThe OXYFERM 120 is dedicated to seating
      Sealed box011-200-00Dial-mounted
      012-200-00Wall-mounted


      VS

      JENCO 6308DT Dissolved oxygen (DO) temperature controllerSpecifications

      LIST VALUE
      DO range 0.00~40.00ppm
      DOS resolution 0.01ppm/0.1%
      Salinity compensation range 0.0~49.9ppt
      Temperature compensation range -10.0~80.0℃
      Pressure compensation range 600~4000mBar
      Measurement range -10.0~120.0℃
      Temperature Resolution 0.1℃
      temperature sensor Thermistor, 22K/25 ℃
      current output 4~ 20mA reversible, isolated current output
      Insulation Voltage/maximum load 500VDC/550Ω
      Control mode In-system ON/OFF control
      Maximum load 2.5A/230VAC
      key All have sound feedback effects
      Dimensions 96*96*148mm
      opening size 92*92mm
      Protection level IP65
      Weight 960g
      Power Supply 230VAC,50/60Hz
      Shop Accessories Electrode, cable, protective cover, electrode seat, sealing box
      Measurement Accuracy ±0.3℃
      DO Measurement Accuracy ±0.2%FS
      DO% Measurement range 0.0~400.0%

      JENCO 6308DT Dissolved oxygen (DO) temperature controller Packing list

      host X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      The film of the dissolved oxygen probe of JENCO6308DT is a little loose, will it affect the test error value?
      [A]
      Hello, yes. When the film is loose, wrinkled, polluted, damaged or bubbled in the electrolysis solution, it will cause reading errors.
      [Q]
      Ren's 6308DT online dissolved oxygen temperature controller uses what type of Sensors?
      [A]
      Hello, Polarographic Dissolved Oxygen Sensors are used.
      [Q]
      Is the 6308DT dissolved oxygen temperature controller to be zero-corrected or saturation-corrected first?
      [A]
      Hello, general users do not need to perform zero correction. If you want to perform zero correction (Z), you need to perform dissolved oxygen saturation correction (S) after zero correction.
      [Q]
      Excuse me, the current output is required to be 15mA. Does this one meet the requirements?
      [A]
      Hello, the current output of the 6308DT dissolved oxygen temperature controller is user-definable and ranges from 4 to 20mA.
      [Q]
      Does the jenco 6308DT need to be corrected after power failure?
      [A]
      Hello, Ren's 6308DT has the function of power-off correction value memory.
      +JENCO 6308DT Dissolved oxygen (DO) temperature controller Big data
        +JENCO 6308DT Dissolved oxygen (DO) temperature controllerSimilar products
        +JENCO 6308DT Dissolved oxygen (DO) temperature controllerKnowledge
        +JENCO 6308DT Dissolved oxygen (DO) temperature controllerStandard
        +Navigation
        JENCO
        JENCO 6308DT on-line dissolved oxygen (DO) temperature controller
        Service
        Focus on online sales of Lab Testing Instruments