DAKOTA PT-102-1000 Low Frequency Probe
The DAKOTA Low Frequency Probe PT-102-1000 has a diameter of 1/4 " (Ø 6.35mm) and is a 225MHz Frequency Ultrasonic Thickness Gauge dual crystal probe with a thickness measurement range of 1.5 to 100mm.
DAKOTA-
KAIRDA N05/90 Ultrasonic Thickness Gauge Probe
Login -
D2012 Ultrasonic Thickness Gauge Probe
$ 214.00 -
DONGRU DR85S Ultrasonic Thickness Gauge 400mm/0.01mm
$ 170.00 -
Ultrasonic steel plate Thickness Gauge DC-2010C Deguang electronic measurement of steel plate material itself Film thickness
$ 817.00 -
SMART SENSOR AS850 Ultrasonic Thickness Gauge measurement range 1.2-225 mm
$ 171.00
Introduction
The DAKOTA low-frequency probe PT-102-1000 has a diameter of 1/4" (Ø6.35mm) and is a 225MHz ultrasonic Thickness Gauge dual element transducer, and the PT-102-1000 has a thickness measurement range of 1.5~100mm.

PT Series Thickness Gauge Probe Parameters
| Model | Thickness range | frequency | Probe diameter | High temperatures |
| PT-102-2000 | 1.0~152mm | 5MHz/wafer | Ø6.35mm | |
| PT-102-2700 | 1.0~152mm | 5MHz/wafer | Ø6.35mm | |
| PT-102-2900 | 1.0~152mm | 5MHz/wafer | Ø6.35mm/CT mode | |
| PT-104-9700 | 2.54~100mm/3.2-100mm(Penetration mode) | 3.5MHz/wafer | Ø12.7mm | |
| PT-101-2000 | 1.0~50mm | 5MHz/wafer | Ø4.76mm | |
| PT-101-2700 | 1.0~50mm | 5MHz/wafer | Ø4.76mm | |
| PT-104-0000 | 3.8~50.8mm(Medium Cast Iron) | 1MHz/wafer | Ø12.7mm | |
| PT-102-1000 | 1.5~100mm | 2.25MHz/wafer | Ø6.35mm | |
| PT-102-3300 | 0.63~152mm | 7.5MHz/wafer | Ø6.35mm | |
| PT-102-3700 | Penetration mode: 5.0~25.4m | 7.5MHz/wafer | Ø6.35mm | |
| PT-104-2000 | 1.27~508mm | 5MHz/wafer | Ø12.7mm | |
| PT-104-2700 | 1.27~508mm | 5MHz/wafer | Ø12.7mm | |
| PT-042-2000 | 1.0~152mm | 5MHz/wafer | Ø6.35mm | 340℃ |
| PT-042-2700 | 1.0~152mm | 5MHz/wafer | Ø6.35mm | 340℃ |
| PT-044-2000 | 1.27~508mm | 5MHz/wafer | Ø12.7mm | 340℃ |
| PT-044-2700 | 1.27~508mm | wafer | Ø12.7mm | 340℃ |
| PT-212-2001 | 1.0~152mm | 5MHz/wafer | Ø6.35mm | 480℃ |
| PT-214-2001 | 1.27~508mm | 5MHz/wafer | Ø12.7mm | 480℃ |
| PT-104-2120 | With PR-82/1.27~380mm | 5MHz | R=50mm | |
| PT-074-2906 | 2.54~100mm | 5MHz/UMX-2 | Ø12.7mm |
DAKOTA PT-102-1000 Low frequency probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 1.5~100mm |
| Probe Frequency | 2.25MHz |
| Probe diameter | Φ6.35mm |
| Probe style | dual crystal probe |
DAKOTA PT-102-1000 Low frequency probe Packing list
Probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


PT-102-1000