JENCO 6308CT online conductivity TDS temperature controller
0µS~ 300.0mS, backlit dot matrix LCD display, waterproof housing, 4~ 20mA isolated output, three sets of relay control, RS-485 interface
JENCO-
JINGQI WD8104 Nitrite Tester
$ 481.00 -
BANTE S60 wireless bluetooth Dissolved Oxygen Meter dissolved oxygen concentration BOD OUR SOUR
$ 357.00 -
HANNA HI93726-01 Photometer Nickel reagent 100 times
$ 462.00 -
Bante902-UK Precision pH/conductivity /TDS/salinity/resistivity meter
$ 607.00 -
QIWEI SS-500B Portable Suspended Solids Tester
$ 271.00
Introducing the JENCO 6308CT Online Conductivity TDS Temperature Controller
Standard 1/4 DIN waterproof body design
The dot matrix backlit LCD display can display the conductivity value, TDS (total dissolved solids) value, and temperature value at the same time
4~20mA reversible, with isolated current output, the output range can be set by the user
Two sets of conductance (TDS) relay control/one set of temperature relay control, control point/hysteresis width can be set by the user
It has the function of automatic temperature compensation
Power-off correction value memory function
RS-485 communication interface is adopted
The products have passed CE certification

Optional
electrode
| Model | Introduction |
| 392-122 | Pure water, ultrapure water field |
| 392-126 | Pure water field |
| 392-125 | Circulating water and general water |
| EC621-01/EC621-001 | Boiler and pure water field |
Sealed box
| Sealed box model | Installation: |
| 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6308CT Conductivity TDS temperature controllerSpecifications
| LIST | VALUE |
|---|---|
| Conductivity range | 0 uS ~ 5.0 mS |
| EC resolution | 0.01 uS ~ 1.0 mS |
| Conductive Accuracy | 0.5% ± 1 LSD |
| TDS range | 0ppm~150.0 ppt |
| TDS resolution | 0.01 ppm to 0.1 ppt |
| TDS Measurement Accuracy | 0.5% ± 1 LSD |
| Measurement range | -10.0~120℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ± 0.1℃ |
| reference temperature | 1.5℃~ 25.0℃ |
| temperature coefficient | 0.0 % ~ 40.0% |
| Basic electrode constant | 0.01,0.1,1.0,10.0 |
| Electrode constant range | Electrode constant +/- 30% |
| relay output | 2 programmable high or low relay conductivity |
| control type | On/Off |
| Relay Output/Maximum Load | 5Amps at 115 VAC, 2.5amps at 230 VAC |
| Relay hysteresis width | user programmable |
| current output | Insulation 4~ 20 mA |
| Measurement range | Selectable zero, & span |
| Accuracy | ±0.02 mA |
| Insulation Voltage/maximum load | 500 VDC |
| maximum load | 500 ohms |
| ATC Sensors | Thermistor 10kiloohms (at 25 ℃) |
| Security, protection | 4 code protection |
| keyboard | Sound feedback |
| link interface | RS-485 |
| Display | Dot matrix LCD, backlight function |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Dimensions | 1/4 DIN, depth 148mm |
| Weight | 950 gm |
JENCO 6308CT Conductivity TDS temperature controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveGB/T 693-2024
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveHJ 2515-2012


6308CT