JENCO 3321 online conductivity resistivity temperature transmitter
0~20.0mS/cm, two sets of relay control, backlit LCD display
JENCO-
HANNA Oxidation-reduction potential calibrating fluid (ORP) 240mV/500mL
$ 148.00 -
BANTE BI-680 industrial online Dissolved Oxygen Meter aquaculture water quality monitoring equipment
$ 455.00 -
HANNA HI76409 Built-in temperature sensor Current dissolved Oxygen electrode
$ 147.00 -
LEICI DJS-1C Conductivity Detector electrode
$ 94.00 -
DOscan10 pen Dissolved Oxygen Meter
$ 347.00
JENCO 3321/3331 Online Conductivity Resistivity Temperature Transmitter Features
Standard 1/8DIN design correction value power-off memory function
With LCD backlit display
4~20mA Isolated Current Output(3331)
Group 2 (Conductivity, Resistivity) Electrical Control(3321)
Automatic/manual temperature compensation function
CE marked

Optional
| Model | Introduction | |
| Conductivity electrodes | 392-122 | Pure water ultrapure water treatment field (can be used below 80°C for a long time) |
| 392-126 | Pure water ultrapure water treatment field (can be used below 80°C for a long time) | |
| 392-125 | Circulating water and general water treatment (can be used below 80°C for a long time) | |
| EC621-001 | Pure water ultrapure water treatment field (can be used below 120°C for a long time) | |
| EC621-01 | Pure water ultrapure water treatment field (can be used below 120°C for a long time) | |
| Sealed box | 011-150-00 | Dial-mounted |
| 012-150-00 | Wall-mounted |
JENCO 3321 Resistivity temperature transmitterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.000uS/cm~19.99mS/cm |
| Resolution | 0.001uS/cm |
| Accuracy | 0.5% +/- 1 word |
| Types of electrode constants | 0.01, 0.1, 1.0 (2-wire Conductivity Detector electrode) |
| reference temperature | 25.0 ℃, factory setting |
| Relay Control Output/Maximum Load | 2 sets of ON/OFF relays in the system control 5A/115VAC or 2.5A/220VAC |
| Dimensions | 1/4DIN standard body, 96 * 48 * 110mm |
| opening size | 92*45mm |
| Power Supply | 100~240VAC,50/60Hz |
| Weight | 200g |
| Shop Accessories | Conductivity electrode, password box |
JENCO 3321 Resistivity temperature transmitter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveHJ 2515-2012
- ActiveASTM D 5682-95-2018
- ActiveHG/T 2003-1991


3321






