FANGRUI LV-SSR digital display Viscometer for a small number of samples
FANGRUI Digital Display Viscometer LV-SSR is an experimental Rotational Viscometer dedicated to small sample testing. It is equipped with four rotors of 18 #, 25 #, 31 #and 34 #. The sample volume only needs 7~ 11ml. The LV-SSR digital display Viscometer has 18 different rotational speeds, measurement Viscosity 3~ 200000mPa·s, standard temperature probe interface.
FangRui-
HBDV-2T Rotational Viscometer Viscosity 800~320 million mPa·s
$ 2148.00 -
TQC DV2010 Viscometer 0-22P For DV2700 Rotothinner Rotational Viscometer
$ 651.00 -
Fungilab Smart R Rotational Viscometer 40 million cP
Login -
NIRUN NDJ-8ST Touch Screen Viscometer Measurement range 1-2 million mPa.s
$ 1005.00 -
HUINUO HBDV-2 Digital Rotational Viscometer 32 million mPa · s 200rpm
$ 1855.00
Introduction
SSR series Digital Rotational Viscometer adopts coaxial cylinder structure, uses a small sample adapter, and requires a very small sample volume for each measurement, only 7ml -13ml (21ml for rotor 0), and can be equipped with a circulating thermostatic water jacket to control the temperature of the measured sample with a thermostatic bath. The operation is very convenient and the measured value is accurate. Ideal for precious, small sample measurements.
Applications
SSR digital viscometer is widely used in the viscosity detection and control of fluids such as greases, paints, coatings, slurries, textiles, foods, adhesives, cosmetics, etc., to meet the viscosity test of a small number of samples.
Features
1. The horizontal bubble is in front, and you can adjust the level while sitting, which is very convenient.
2. There is a timing measurement function.
3. Coaxial cylindrical structure.
4. The measurement accuracy of the data is two decimal places.
5. Convenient and reliable operation.
6. With a small number of sample adapters, the sample volume required for the test is very small.
7. The viscometer comes with two RS232 interfaces, which can be directly connected to the micro thermal printer and computer.
Options
1. Enhanced Ultra Low Viscosity Adapter ULR (No. 0 Rotor)
Designed for low viscosity fluid measurements
There are two types of jacketed and non-jacketed versions
The minimum detection limit is 1cP, depending on the viscometer used
Model: Stainless steel material is easy to clean and clean
It can withstand the operating temperature range of -40°C-200°C
2. DC0506W type special low-temperature thermostat for viscometer
Comparison of SSR parameters
| Instrument model | rotate speed | rotor | Range | Sample size |
| LV-SSR | 0.3~100 | 18#,25#,31#,34# | 1-200,000 | 7~11 |
| RV-SSR | 0.5~100 | 21#、27#、28#、29# | 6.4-2M | 7.8~11.5 |
| HA-SSR | 12.8~4M | |||
| HB-SSR | 51.2~16M | |||
| *Measuring range M=1000000 unit:r/min、mPa·s、ml | ||||
| Other parameters | ||||
| Measurement error | ±2% (Newtonian liquid) | |||
| Repeatability | ±1% (Newtonian liquid) | |||
| Output interface | There are two RS232 interfaces to connect the printer and the computer | |||
| Temperature probe interface | Standard | |||
| Dimensions | 300×300×450mm | |||
FangRui LV-SSR ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 3~200000mPa·s |
| Rotor Specifications | 18 #, 25 #, 31 #, 34 #(optional ULR0 rotor) |
| Rotor speed | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 A total of 18 kinds |
| Reproducibility | ±1%F.S |
| Measurement Accuracy | ±2% |
| Capacity | 7~11ml |
| Data Interface | There are two RS232 interfaces, which can connect printers and computers |
| Dimensions | 300*300*450mm |
| Operating language | Chinese |
| Temperature probe interface | Standard |
| Measuringflask depth | About 70mm |
| Measuringflask outer diameter | 28mm |
| ULR (No. 0 rotor) range | 1~1000mPa·s |
| No. 18 rotor range | 3~10000mPa·s |
| No. 25 rotor range | 4.8~ 1.6 million mPa·s |
| No. 31 rotor range | 30~100,000 mPa·s |
| No. 34 rotor range | 600,000~200,000 mPa·s |
| ULR (No. 0 rotor) sample Volume | 21ml |
| No. 18 rotor sample Volume | 7ml |
| No. 25 rotor sample Volume | 9ml |
| No. 31 rotor sample Volume | 10.5ml |
| No. 34 rotor sample Volume | 11ml |
FangRui LV-SSR Viscometer Packing list
Viscometer host * 1, lifting column * 1, base * 1, 18 #, 25 #, 31 #, 34 #rotor * 1 each, connecting frame * 1, sample cylinder * 1, operation manual * 1, power adapter * 1, certificate/warranty card * 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Installation and use of Fangrui Rotational Viscometer No. 0 rotor
- How to choose a Rotational Viscometer? This is enough
- Rotational viscometer selection suggestions
- Working principle and application of Spinning & weaving slurry Viscometer
- Installation Steps for Digital Viscometer
- Fangrui NKY-25 Viscometer Temperature Controller Instructions for Use
- Thixotropic Cracking Coefficient Method for Determination of Ink Rheology
- Shanghai Fangrui NDJ/SNB/DV T series digital display Rotational Viscometer installation method
- Fangrui SNB-1A/NDJ-1C viscometer rotor installation specific steps
- Precautions for the use of Rotational Viscometer
- ActiveQB/T 2568-2002
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- AbolishGB/T 12008.7-2010
- ActiveGB/T 13217.4-2020
- ActiveGB/T 12009.3-2009
- AbolishGB/T 11175-2002
- ActiveGB/T 1981.3-2009


LV-SSR
HB-SSR
HA-SSR
RV-SSR