JENCO 6TX online pH oxidation reduction transmitter
JENCO 6TX online pH oxidation reduction transmitter PH Measurement range -2.00~16.00pH, PH Measurement accuracy +/- 0.01pH, resolution 0.01pH, ORP Measurement range -1000~1000mV, ORP resolution 1mV, ORP Measurement accuracy +/- 1mV
JENCO-
DDKSIC PH100 Laboratory pH Meter pH/mV (ORP electrode optional)/℃
$ 307.00 -
DDKSIC PH10 Color Screen Portable pH Meter pH/mV (ORP electrode optional)/℃
$ 462.00 -
YUEPING PHS-3CU acidity meter Measurement range (-2.00~19.99) pH temperature (0.0~80.0) ℃
$ 228.00 -
Shima AS218 PH value Detector 0.00~14.00
$ 150.00 -
LEICI T-818-B-6 temperature electrode
$ 125.00
Overview of the JENCO 6TX On-Line pH Redox Transmitter
Standard 1/4 DIN waterproof body design
LCD display, can display pH value, ORP value, temperature value at the same time
4~20mA with isolated current output
pH has automatic/manual temperature compensation
Power-off correction value memory function
12~36VDC power supply
Model 6TX Industrial In-Line pH/Redox (ORP) Transmitter Optional Accessory
| Model | Introduction |
| ST873 | High temperature field |
| IP-600-1 | Biological fermentation at room temperature and wastewater treatment with high turbidity |
| IP-600-10 | General wastewater treatment field |
| IP-600-9(PT) | With temperature compensation, in the field of general wastewater treatment |
| IR-500-9N | General wastewater treatment field |
| IR-500-8 | General wastewater treatment field |
| Sheath tube | |
| 009A | 1 meter tube length |
| Sealed box | |
| 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6TX (set) pH oxidation reduction transmitterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Measurement range | -10.0~120.0℃ |
| Impedance | >10^13Ω |
| Power Supply | 12 ~ 36 V DC |
| Weight | 600grams |
| Measurement range mV | -1000~1000mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±1mv |
| Measurement range | 10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ± 0.3 ℃ |
| pH buffer recognition | US (4.01, 7.00, 10.01) or NIST (4.00, 6.86, 9.18) users can choose |
| pH electrode zero correction range | ± 90 mV |
| pH electrode slope (slope) identification | ±30% |
| input selection | Users can choose between pH and ORP. |
| Current output range | 4 - 20 mA (insulation), programmable design |
| Environmental temperature | 0~50℃ |
| Shell material | Case IP 65, 1/4 DIN case, depth 148 mm |
| Temperature compensation method | Automatic or manual operation |
JENCO 6TX (set) pH oxidation reduction transmitter Packing list
Host X1, IP-600-9TH (5 meters) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJF 919-2023
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 23997-2009
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveJB/T 6858-1993
- ActiveHG/T 4164-2010
- ActiveQB/T 4103-2010
- ActiveGB/T 2750-2011
- ActiveGB/T 27756-2011


6TX (set)