TIME2510 (formerly TT210) Plastic Film Thickness Gauge eddy current and magnetic integration
TIME2510 Plastic Film Thickness Gauge (formerly TT210) is a portable magnetic and eddy current Thickness Gauge, which can quickly, non-destructive and precise measurement of nonmagnetic coating thickness on magnetic metal substrate and nonconductive coating thickness on nonmagnetic metal.
TIME-
DONGRU DR280 dual-use Coating Thickness Gauge
$ 316.00 -
PHYNIX Surfix SX-F1.5 magnetic Film Thickness Gauge 1500μm
Login -
DUBAN DB22-CM222H Anti-corrosion layer Thickness Gauge
$ 671.00 -
List MEGA-CHEK Master Storage Fast Scan Platings Thickness Gauge
$ 2123.00 -
AMITTARI AC-990u paints Thickness Gauge, dual function, thickness measurement range 0~500μm
$ 231.00
Overview
Beijing TimesTIME2510 plastic Film Thickness Gauge(formerly TT210) is a portable magnetic and eddy current Thickness Gauge that can quickly and accurately measure the thickness of non-magnetic overlays on magnetic metal substrates. It can be used both in the laboratory and in the engineering field. It can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. Due to the small size of the instrument and the integration of the probe and the instrument, it is particularly suitable for on-site measurements.
The following criteria are met
GB/T 4956─1985 Measurement of thickness of non-magnetic overlay on magnetic metal substrate -- Magnetic method
GB/T 4957─1985 Measurement of thickness of non-conductive overlay on non-magnetic metal substrate -- Eddy current method
JB/T 8393─1996 Magnetic and eddy current cladding thickness measuring instrument
JJG 889─95 Magnetoresistive Thickness Gauge
JJG 818─93
Features
1. The magnetic thickness measurement method can measure the thickness of the non-magnetic covering layer on the magnetic metal matrix (such as zinc, aluminum, steel, rubber, paint, etc. on steel, iron, alloy and hard magnetic steel) without damage
2. The eddy current measurement method can be used to measure the thickness of the non-conductive layer on the non-magnetic metal matrix without damage(Such as paints, rubber, plastics, oxide films, etc. on metals such as copper, aluminum, zinc, tin, etc.)
3. Zero-point calibration and two-point calibration can be carried out, and the systematic error of the probe can be corrected by the basic calibration method
4. There are two measurement methods: continuous measurement mode and single measurement mode
5. It has two Operating Modes: direct mode and batch group mode
6、TIME2510 plastic Film Thickness Gauge is available500 measured values are stored
7. Its useful functions: delete the current value, calibration value, limit value, and all values
8. There are five statistics: average, maximum, minimum, number of tests, and standard deviation
9. It has the function of printing, which can print measured values and statistical values
10. It has the function of under-Voltage indication
11. There is a buzzer prompt during the operation
12. It has the function of error prompt
13. Chinese and English menus are adopted
14. Backlight display, convenient for measurement in low-light environment
15. Automatic and manual shutdown dual functions
16、TIME2510 plastic Film Thickness GaugeOne probe is used
Actual picture of the product

TIME TIME2510(原TT210) Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | 0~1250μm |
| margin of error | ±3% |
| Resolution | 0.1μm |
| Minimum measurement surface | Φ7mm(F);Φ5mm(N) |
| thinnest substrate | 0.5mm(F);0.3mm(N) |
| probe | F and N integrated probe |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| icon function | without |
| Standards | GB/T 4956-1985、GB/T 4957-1985、JB/T 8393-1996、JJG 889-95、JJG 818-93 |
| Calibrated Certificate | without |
| system language | Chinese |
| Display screen | LCD screen |
| supporting software | without |
| Machine Weight | 100g |
| Machine size | 110*50*23mm |
| Operating temperature | 0~40℃ |
| Optional accessories | TA230 printer |
| Relative Humidity | 10~90%RH |
TIME TIME2510(原TT210) Thickness Gauge Packing list
host x1, standard sample x1, standard base x1, charger x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Introduction of calibrating method of metal coating Thickness Gauge
- Film Film thickness determination method
- Coating Film thickness determination method
- Coating construction performance testing Application instrument type summary
- Beijing Infrared Times TT210 Ultrasonic Thickness Gauge Operation Instructions
- Operation steps and precautions of galvanized layer Thickness Gauge
- Painting quality control process introduction
- Study on BOPP to Improve Large Film thickness
- Film Film thickness detection method
- Reasons for measurement deviation of Coating Thickness Gauge