JENCO 6311 online pH oxidation reduction temperature controller
Isolation 4~ 20mA, -2~ 16/0.01 pH, automatic temperature compensation -10.0~120 ℃, five sets of relay control, standard Modbus protocol 5000.00 (stand-alone)
JENCO-
LEICI PHBJ-260F Portable pH Meter pH/mV/Temperature 0.01 Class, Touch Screen
$ 585.00 -
PHS-3C laboratory acidity meter pH value/mV (ORP)
$ 173.00 -
KODIDA CT-6821 Industrial pHmeter ORP
$ 127.00 -
FANGZHOU PHS-3C + economical acidity meter pH/mV/ORP/temperature value 0.01 grade
$ 406.00 -
YUEPING PHS-3CB acidity meter Measurement range: (-2.00~ 19.99) pH intrinsic error +/- 0.01pH
$ 200.00
Introducing the JENCO 6311 In-Line pH Redox Temperature Controller
Standard 1/4 DIN waterproof body design
Liquid crystal display, which can display pH value, ORP value, and temperature value at the same time
pH electrode efficiency display
4~20mA reversible, with isolated current output, the output range can be set by the user
Four sets of pH (ORP) relay control/one set of cleaning relay control, control point/hysteresis width can be set by the user
Automatic temperature compensation, user-selectable temperature probe (PT1000, TH10K, BALCO3K)
Power-off correction value memory function
RS-485 communication interface is adopted
The products have passed CE certification

pH electrode
| Model | Introduction |
| ST873 | High temperature field |
| IP-600-1 | Biological fermentation at room temperature and wastewater treatment with high turbidity |
| IP-600-10 | General wastewater treatment field |
| IP-600-9(TH) | With temperature compensation, in the field of general wastewater treatment |
| ORP | |
| IR-500-9N | General wastewater treatment field |
| IR-500-8 | General wastewater treatment field |
Sheath tube
| Model | Introduction |
| 009A | 1 meter tube length |
Sealed box
| Model | Introduction |
| 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6311 pH oxidation temperature controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 96*96*148mm |
| opening size | 92*92mm |
| Measurement range mV | -2500~2500mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.1% |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.3℃ |
| Current output range | 4~ 20mA reversible, isolated current output |
| Insulation Voltage/maximum load | 500VDC/550Ω |
| Relay Control Output/Maximum Load | System ON/OFF control/2.5A/230VAC |
| protective measures | 4-Digit password protection |
| Shop Accessories | PH electrode, ORP electrode, mounting bracket, sealing box |
JENCO 6311 pH oxidation temperature controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveQB/T 2724-2005


6311