Introduction
The JENCO 6309POT pH&ORP Analyzer is an RS-485 online conductivity meter with 4 relays and a 4/1DIN IP-65 housing.
pH/ORP/temperature measurement & control
Displays the pH electrode rate
Users can choose from ATC elements: 3k balco, 10k and pt-1000
Reversible & Insulated 4-20mA output
RS-485 output
Easy calibration
Dot matrix LCD display 128 x 64, backlit function
Thin-film converter voice reply
Automatic temperature compensation
High-pitched dryness (50/60 Hz)
Can be placed on pipes/walls/frames
1/4 DIN water resistant
1. Programmable temperature relay
EU Certification
Programmable linear/ORP current output or programmable linear/opposed
number of current outputs

| Optional | ||
| pH electrode | IP-600-1 | Wastewater treatment with high turbidity |
| IP-600-10 | General wastewater treatment field | |
| IP-600-9(TH) | General wastewater treatment field | |
| Redox electrodes | IP-500-8 | General wastewater treatment field |
| IP-500-9 | General wastewater treatment field | |
| Sheath tube | 9 | 1 meter tube length |
| Sealed box | 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6309POT PH/oxidation/temperature controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Impedance | >10^12Ω |
| Power Supply | 230VAC,50/60Hz |
| Dimensions | 96*96*148mm |
| Weight | 960g |
| pH Buffer Identification Solution | Users can choose from any of 4.01, 7.00, 10.01 or 4.00, 6.86, 9.18 |
| pH electrode zero/slope compensation | ±100mV/±30% |
| Measurement range mV | -2500~2500mV |
| Measurement range mV | -6499~6499mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | 0.1%F.S |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature sensor | Thermistor, 10K/25 ℃ |
| Current output range | 4~ 20mA reversible, isolated current output |
| Insulation Voltage/maximum load | 500VDC/500Ω |
| Control mode | In-system ON/OFF control |
| Maximum load | 2.5A/230VAC |
| key | All have sound feedback effects |
| Various protection measures | 4-Digit password protection |
| opening size | 92*92mm |
| Protection level | IP65 |
| Shop Accessories | pH electrode, oxidation electrode, sheath, sealing box |
| Measurement Accuracy | ±0.3℃ |
JENCO 6309POT PH/oxidation/temperature controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveQB/T 2724-2005


6309POT