JENCO 6308PT online pH temperature controller
-2~ 16/0.01 pH, dot matrix backlit LCD display, waterproof housing, 4~ 20mA isolated output
JENCO-
FANGZHOU FZ-861 PH Glass electrode electrolysis solution, Eletroplating solution, chemical reagent PH test
$ 254.00 -
HANNA HI99121 Waterproof portable acidity pH-temperature Tester, soil agriculture
$ 854.00 -
Qiwei PH-20W pen acidity meter, small size, easy to carry
$ 103.00 -
FANGZHOU FZ-231 Open PH electrode testing wastewater, emulsion, suspension, etc
$ 234.00 -
YueFeng PHBJ-260 Portable Acidity Meter 0~18.0pH
$ 207.00
Introducing the JENCO 6308PT In-Line pH Temperature Controller
Standard 1/4 DIN waterproof body design
It can display both pH value and temperature value at the same time
pH electrode efficiency display
4~20mA reversible, with isolated current output, the output range can be set by the user
Four sets of pH relay control/one set of temperature relay control, control point/hysteresis width can be set by the user
It has the function of automatic temperature compensation
Power-off correction value memory function
RS-485 communication interface is adopted
The products have passed CE certification

Displays a description

(1) Efficiency: The corrected efficiency of the electrode is displayed here.
(2) Current: Displays the output size of the actual isolation current. There are three other display cases:
a. When the input signal is not stable within 3 seconds after powering on, it will be displayed as the word "stop".
b. When the difference in the set value of the current output is less than 0.1 pH, it is displayed as an "error".
c. When entering the correction/setting mode or returning to the normal display screen from the correction/setting mode, it will be displayedThe word "lock" is displayed, and it is displayed for about 2 seconds.
(3) : The key indicator signal is lit to indicate that the set mode is password protected, unless enabledThe user then enters the correct four-digit password, otherwise all the set parameters can only be viewedIt can be changed again.
(4) H1: Indicator signal - When the indicator signal of H1 is on, it means that the pH value of RELAY1 has been exceededThe setpoint of the control.
(5) H2: Indicator signal – When the indicator signal of H2 is on, it means that the pH value of RELAY2 has been exceededThe setpoint of the control.
(6) L3: Indicator signal - when the indicator signal of L3 is on, it means that the pH value of RELAY3 has been loweredThe setpoint of the control.
(7) L4: Indicator signal – When the indicator signal of L4 is on, it means that the pH value of RELAY4 has been loweredThe setpoint of the control.
(8) H5/L5: Indicator signal -- when the indicator signal of H5/L5 is lit, it indicates the temperature display of RELAY5The signal value has exceeded/fallen below the control set value.
(9) Measured pH.
(10) Measured temperature display
Optional
pH electrode
| Model | Introduction |
| IP-600-1 | Wastewater treatment with high turbidity |
| IP-600-10 | General wastewater treatment field |
| IP-600-9(PT) | With temperature compensation, in the field of general wastewater treatment |
| EASYFERM Plus | In the field of biological fermentation, it can withstand 135°C steam sterilization |
| IP-600-3CN | Pure water treatment field |
Sheath tube
| 010 | EASYFERM Plus |
| 009A | 1 meter tube length |
| EASYFERM Plus sheathed tubing | EASYFERM Plus |
| The electrodes are seated | Dedicated seating for EASYFERM Plus |
Sealed box
| 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6308PT pH temperature controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 96*96*148mm |
| opening size | 92*92mm |
| Protection level | IP65 |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.3℃ |
| Current output range | 4~ 20mA reversible, isolated current output |
| Insulation Voltage/maximum load | 500VDC/550Ω |
| Relay Control Output/Maximum Load | System ON/OFF control/2.5A/230VAC |
| protective measures | 4-Digit password protection |
| Preset amplifier Voltage output | +/- 5VDC, maximum output current 20mA |
| Shop Accessories | PH electrode, mounting bracket, sealing box |
JENCO 6308PT pH temperature controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005
- ActiveQB/T 2724-2005


6308PT