JENCO 3675 (set) online pH oxidation reduction controller
The JENCO 3675 (set) online pH oxidation reduction controller is a pH oxidation reduction controller that can measure the pH value, and can also measure the Oxidation Reduction Potential. The measurement range, measurement accuracy and resolution of the 3675 (set) pH oxidation reduction controller are 0~14.0 pH, +/- 0.01pH +/- 1 word, 0.01 pH.
JENCO-
LEICI 962242 Planar pH composite electrode for surfaces or droplet samples
$ 242.00 -
FANGZHOU FZ-243-6 Semi-micro PH electrode with temperature compensation
$ 316.00 -
LEICI PHSJ-4F Laboratory pH Meter 0.001 PH/mV/Temperature
$ 700.00 -
PH828 + pen pH meter
$ 111.00 -
FANGZHOU PHBJ-360F Portable pH Meter ph Portable acidity meter 0.001 grade
$ 689.00
Introducing the JENCO 3675 Online pH Redox Controller
Standard 1/4 DIN molded body design
The same instrument can measure the pH value, and the redox potential value can also be measured
LCD Display(3675)/LED Display(3676)
Two sets of relay control, the control point can be set by the user
4~20mA with isolated current output
It has the function of automatic temperature compensation
It is an affordable pH/ORP controller and transmitter

Optional
| Optional | ||
| pH electrode | IP-600-1 | In the field of wastewater treatment with high turbidity, it can be used in a long-term environment of 80 degrees |
| IP-600-10 | In the field of ordinary carved water treatment, there is no temperature compensation | |
| IP-600-9PT | In the field of ordinary carved water treatment, automatic temperature compensation | |
| IP-600-3C | Pure water, ultrapure water measurement | |
| ORP electrodes | IR-500-8 | In the field of general wastewater, -2000mV~2000mV |
| IR-500-9 | In the field of general wastewater, -1000mV~1000mV | |
| Mounting bracket | 009A | 1 meter pool mounting bracket |
| Sealed box | 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted | |
JENCO 3675 (set) pH oxidation controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -0.00~14.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 1/4DIN standard body, 96 * 96 * 119mm |
| Measurement range mV | -1999~1999mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.5%F.S |
| Current output range | 4~ 20M isolated current output |
| Insulation Voltage/maximum load | 500VDC/550Ω |
| Relay Control Output/Maximum Load | System ON/OFF control/2.5A/230VAC |
| opening size | 92*92mm |
| Shop Accessories | pH electrode, ORP electrode, mounting bracket, sealing box |
| Display | LCD display |
JENCO 3675 (set) pH oxidation controller Packing list
Host X1, IP-600-10 (20 meters) X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 8077-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveGB/T 35464-2017
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008


3675 (set)