JENCO 6313 online pH oxidation reduction controller pH/ORP test
Isolation 4~ 20mA, -2~ 16/0.01 pH, automatic temperature compensation -10.0~120 ℃, two sets of relays control 4000.00 (single machine)
JENCO-
Bante210-UK Precision Laboratory pH Meter
$ 321.00 -
HANNA HI98127 pH Measurement Instrument - 2.0~16.0pH
$ 257.00 -
Qiwei PHS-3CW pH meter (desktop microcomputer)
$ 145.00 -
DDKSIC 201T-H triple composite pH electrode environmental protection, chemical industry, energy, conventional water sample measurement
$ 112.00 -
Bante221-UK portable pHmeter with P11 Glass PH electrode
$ 438.00
Introduction
ONLINE PH/ORP MEASURING INSTRUMENT, A VERY CLASSIC ONLINE PH/ORP MEASURING INSTRUMENT. Relay control function, 4-20mA output. It is widely used in sewage treatment plants, enterprise production lines.
Features
Standard 1/4DIN waterproof body design
Liquid crystal display, which can display pH (ORP) and temperature values at the same time
4~20mA reversible, with isolated current output, user-configurable
Two sets of relay control, control point, hysteresis width can be set by the user
Automatic temperature compensation for self-selectable temperature probe (PT1000, TH10K, BALCO3K)
Correction value power-off memory function
The products have passed CE certification

Optional
pH electrode
| Model | Introduction |
| IP-600-9TH | General wastewater treatment (can be used below 70°C for a long time) |
| ST873 | High-temperature field (can be used below 105°C for a long time) |
| IP-600-1NTH | General wastewater treatment (can be used below 90°C for a long time) |
| IP-600-3CNTH | Pure water pH composite electrode (pure water, ultrapure water measurement) |
Redox electrodes
| Model | Introduction |
| IR-500-8 | General water treatment field |
| IR-500-9 | General water treatment field |
Sheath tube
| Model | Introduction | |
| Sheath tube | 009A | |
Sealed box
| Model | Introduction |
| 011-200-00 | Dial-mounted |
| 012-200-00 | Wall-mounted |
JENCO 6313 pH oxidation controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| Measurement Accuracy | +/- 0.1% +/- 1 word |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 96*96*148mm |
| PH standard solution | US (4.01, 7.00, 10.01) or (4.00, 6.86, 9.18) user-selected, automatic two-point correction |
| Data storage for pH correction | Yes. |
| Current output range | A set of 4~ 20mA reversible, isolated current outputs |
| Insulation Voltage/maximum load | 1000VDC/550Ω |
| opening size | 92*92mm |
| protective measures | 4-Digit password protection |
| Relay Control Output/Maximum Load | Two sets of ON/OFF control in the system 2.5A/230VAC |
| Measurement range mV | -2500~2500mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.1%F.S |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.3℃ |
| Shop Accessories | PH electrode, ORP electrode, mounting bracket, sealing box |
JENCO 6313 pH oxidation controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveGB/T 35464-2017
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 13531.1-2008
- ActiveGB/T 11165-2005