JENCO 6309PDT pH dissolved oxygen temperature controller -2.00~16.00pH
JENCO 6309 pH dissolved oxygen temperature controller pH range of -2.00~16.00pH, is an online pH, DO, temperature analyzer, JENCO 6309 has automatic temperature compensation function, widely used in swimming pool measurement, sewage measurement.
JENCO-
BANTE E202-BNC planar pH electrode for measurement of semi-solid samples
$ 102.00 -
LEICI PHBJ-261L Portable pH Meter Potential pH ORP Temperature 0.001 Grade
$ 803.00 -
Kodida CT-6658 PH/ORP Controller, Industrial pHmeter with electrodes CT-1001
$ 239.00 -
LEICI 962242 Planar pH composite electrode for surfaces or droplet samples
$ 242.00 -
LEICI 65-1C pH composite electrode (glass shell)
$ 94.00
Introduction
JENCO 6309PDTF On-line pH, DO, Temperature Analyzer. 1/4 DIN, IP-65 spec, panel mount pH/DO/temperature analysis, 2-wire 4-20mA current output, 2 programmable switching relays, RS-485 output, backlight function.
Features
Standard 1/4DIN waterproof body design
128x64 dot matrix backlit LCD display, which can display pH, dissolved oxygen value and temperature value at the same time
pH electrode efficiency display
4~20mA reversible, with isolated current output, the output range can be set by the user
Two sets of pH relay control / two groups of dissolved oxygen relay control / one set of temperature relay control
The control point/hysteresis width can be set by the user
It has the function of automatic temperature compensation
Power-off correction value memory function
RS-485 communication interface is adopted
The products have passed CE certification

Optional
| Model | Introduction | ||
| pH electrode | IP-600-1 | Wastewater treatment with high turbidity | |
| IP-600-10 | General wastewater treatment field | ||
| Dissolved oxygen electrodes | OXYSENS 120 | Sewage and aquaculture fields | |
| Sheath tube | 009A/B | 1 meter tube length | |
| Sealed box | 011-200-00 | Dial-mounted | |
| 012-200-00 | Wall-mounted | ||
JENCO 6309PDT pH dissolved oxygen temperature controllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.00~16.00pH |
| PH Measurement Accuracy | ±0.01pH |
| Resolution | 0.01pH |
| Power Supply | 110或230VAC,50/60Hz |
| Dimensions | 96*96*148mm |
| DO range | 0.00~60.00ppm, 0~500.0% |
| DOS resolution | 0.01ppm(1%) |
| DO Accuracy | ±0.2%F.S. |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.3℃ |
| 4~ 20mA current output | 4~ 20mA reversible, isolated current output |
| Dissolved oxygen salinity compensation range | 0-49.9ppt |
| Dissolved oxygen pressure compensation range | 600-1100mbar |
| Insulation Voltage/maximum load | 500VDC/550Ω |
| protective measures | 4-Digit password protection |
| Preset amplifier Voltage output | +/- 5VDC, maximum output current 20mA |
| opening size | 92*92mm |
| Shop Accessories | PH electrode, mounting bracket, sealing box |
JENCO 6309PDT pH dissolved oxygen temperature controller Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJF 919-2023
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022


6309PDT