PORUIKE BT-180A Ultrasonic Thickness Gauge (0.5-400 mm)
PORUIKE BT-180A Ultrasonic Thickness Gauge Sensors Contact temperature within 60 degrees Celsius, is a portable Ultrasonic Thickness Gauge with 10mm diameter probe, BT-180A Ultrasonic Thickness Gauge measurement error of +/- 0.05mm and (+/- 0.5% H + 0.01) mm, with automatic sleep, automatic shutdown and other power saving functions.
PoRuiKe-
PRUT310 Ultrasonic Thickness Gauge Display Resolution 0.001mm
Login -
Linshang LS212 Professional Ultrasonic Thickness Gauge Thickness Measurement 0.8~ 350mm
$ 273.00 -
AMITTARI AT-140A Ultrasonic Thickness Gauge 0.1mm resolution Probe diameter φ 8mm, 5HZ
$ 327.00 -
Leeb322 Ultrasonic Thickness Gauge with a display resolution of 0.01mm
Login -
SMART SENSOR AR860 Ultrasonic Thickness Gauge measurement range 1.0~300mm
$ 296.00
Overview
High-precision ultrasonic Thickness Gauge BT180A is a new generation of intelligent ultrasonic Thickness Gauge dedicated to materials below 300°C, using a new high-temperature probe, high-performance, low-power microprocessor technology, based on the ultrasonic measurement principle, it can measure the thickness of high-temperature resistant cast iron and steel materials, and measure the sound velocity of materials. It is widely used in thickness measurement of various plates, pipe wall thicknesses, boiler vessel wall thicknesses, various pipes and pressure vessels, and monitors the degree of thinning after corrosion during use.

Features
It is suitable for measuring the thickness of good conductors of ultrasonic materials made of metals (e.g. steel, cast iron) below 300°C
It can be equipped with a variety of dual element transducers with different frequencies and different element sizes
It has the functions of zero point calibration and two-point calibration of the probe, which can automatically correct the system error
Known thicknesses can be used to backmeasure the speed of sound to improve measurement accuracy
It has a coupling status prompt function
There is an LED backlit display for easy use in low-light environments
There is a residual battery indication function, which can display the remaining battery power in real time
It has power-saving functions such as automatic sleep and automatic shutdown
Small, portable, and highly reliable, it is suitable for harsh operating environments and is resistant to vibration, shock and electromagnetic interference
Probes are optional
| name | Model | frequency | Probe diameter | Measuring range | The surface temperature of the object to be measured | Description |
| Standard probes | N05、N05/90 | 5MHz | 10mm | 0.5mm~400mm(Steel) | -10~60℃ | Use at room temperature (<60°C) |
| Coarse-grain probes | N02 | 2MHz | 12mm | 3.0-300.0mm(Steel) | -10~60℃ | It is used for measuring coarse-grained materials such as cast iron |
| 5.0-40.0mm(Cast Iron) | ||||||
| Microdiameter probes | N07 | 7MHz | 6mm/4mm | 0.65mm~260mm(Steel) | -10~60℃ | It is used for the measurement of thin walls and small cambers |
| High temperature probes | HT5 | 5MHz | 14mm | 3mm~200mm(Steel) | -10~400℃ | It is used for the measurement of materials with temperatures less than 350°C |
PoRuiKe BT-180A Ultrasonic Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.5-400.0mm |
| Probe Frequency | 5MHz |
| Probe diameter | Φ10mm |
| Probe contact temperature | -10~300℃ |
| Lower limit of pipe measurement | Φ20*3mm |
| measurement error | ±(0.5%H+0.04)mm |
| Display resolution | 0.01Mm optional |
| unit system | Metric/Imperial |
| Calibration method | Zero point calibrated, two point calibrated |
| Storage Capacity | Can store 20 groups (up to 100 Measured values per group), view and delete |
| Speed of sound | 1000~9999m/s |
| Display | 128 × 64LCD display, high luminance EL backlight |
| Interface | RS232 interface for exporting data |
| Power Supply | 2 AA type alkaline batteries 1.5V |
| Operating Time | Up to 250 hours of continuous operation (without backlight) |
| Host size | 150×74×32mm |
| Weight | 238g |
| minimum thickness value capture capability | Capable of capturing minimum thickness values |
| Measurement speed | 4 times/second for single point measurement, 20 times/second for scanning mode |
| Calibrating block | 4.0Mm (steel) |
| Probe Specifications | φ 6 mm (optional), φ 10 mm (optional), φ 12 mm (optional) |
| Optional probe | 2MHz, 7MHz, 5MHz (high temperature), 5MHz (standard) |
PoRuiKe BT-180A Ultrasonic Thickness Gauge Packing list
Host x1, 5MHz high temperature probe X1, high temperature coupler X1, 4.0 mm steel calibrated block X1, battery (non-aviation) X2
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Types and Usage Methods of Coupling Agent for Thickness Gauges
- The Principle, Application and Precautions of Copper Plate Ultrasonic Thickness Gauge
- Principle, Application and Selection of Ceramic Ultrasonic Thickness Gauge
- Principle, Application and Type Selection of Ultrasonic Thickness Gauge
- Principle, Application and Type Selection of Ultrasonic Thickness Gauge


BT-180A