      LINSHANG LS223 + F3N3 Portable Coating Thickness Gauge

      LINSHANG portable Coating Thickness Gauge LS223 + F3N3 is equipped with F3N3 dual function probe, using Hall effect and eddy Current thickness measurement principle, the thickness measurement range is 0.0~3000 microns, LS223 Coating Thickness Gauge measurement interval is 0.5s, no need to calibrate.

      Brand
      SKU: NB029832
      China LinShang
      VS
      Genuinegoods
      • LinShang LS223+F3N3 Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      LS223+F3N3
      Coating Thickness Gauge

      Introduction

      The LS223 coating Thickness Gauge can be used not only for coating ferromagnetic metal substrates such as steelMeasurement of non-magnetic coatings such as materials, varnishes, enamels, chromium, galvanization, etc., can also be used for copper, aluminum, and pressingNon-conductive coatings, anodized layers, ceramics and other non-magnetic metal substrates such as cast zinc and brassMeasurement of electric coatings. The instrument automatically recognizes the type of measurement substrate and automatically switches the measurement mode.

      It is widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other fields.

      depend onAccording to the standard

      GB/T4956-2003 Thickness measurement of non-magnetic overlay on magnetic substrate - magnetic method

      GB/T4957-2003 Thickness measurement of non-conductive overlay on metal of non-magnetic matrix-

      Eddy current method

      DIN ENISO2808 Determination of paint film thickness for coatings and varnishes

      JJG-818-2005 V. R. of Magnetic and Eddy-current Coverage Thickness Measuring Instrument

      Features

      1. No need to calibrate, just zero adjustment.

      2. Separate buttons, the operation is very simple.

      3. The measurement is fast, and a measurement can be completed in 0.5 seconds.

      4. Ultra-large range test, the thickest can be measured up to 5mm.

      5. The wear resistance of the ruby probe ensures the long-term and effective use of the instrument.

      6. Iron and aluminum dual-purpose probe, automatic identification of the measurement substrate, can be quickly and automatically converted.

      7. "Fe", "NFe", "Fe/NFe" three measurement modes can be set.

      8. It can measure the thickness of the non-magnetic overlay on magnetic metal substrates such as steel, and the thickness of non-conductive overlays on non-magnetic metal substrates such as copper and aluminum.

      9. Using professional digital probe technology, digital signal processing is completed directly on the probe, the probe is not easy to be disturbed and provides excellent test accuracy. Even temperature changes do not affect the measurement, and the readings remain stable to ensure very good repeatability throughout the measurement.

      VS

      LinShang LS223+F3N3 Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle Hall effect/eddy Current
      Measurement range Fe:0.0~3000μm;NFe:0.0~3000μm
      margin of error ±3%
      Resolution 0.1μm|1μm|0.01mm
      Minimum measurement surface Φ25mm
      Minimum radius of curvature Convex: 5mm; Concave: 25mm
      thinnest substrate 0.2mm(F);0.05mm(N)
      probe Line probe
      Probe size 22*26*55mm
      Probe material ruby
      Calibrated mode No need to calibrate, just zero
      Measurement mode "Fe"、"NFe"、"Fe/NFe"
      Unit display μm/mil
      Power Supply 2 1.5V AA alkaline batteries
      Standards GB/T4956-2003、GB/T4957-2003、DIN EN ISO 2808、JJG-818-2005
      system language Chinese
      Display screen 128x
      Operating temperature 0~50℃
      Print function none
      Machine Weight 160g
      Machine size 126*66*35mm
      Storage temperature -20~60℃

      LinShang LS223+F3N3 Coating Thickness Gauge Packing list

      LS223 Coating thickness gauge x1, Fe zero plate x1, NFe zero plate x1, standard sheet x1, manual x1, certificate x1, 1.5V AA alkaline battery x2

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Under what circumstances does the paint film instrument need to be zeroed?
      [A]
      The following situations need to be used after zero adjustment of the two iron and aluminum zero adjustment plates: 1. The test zero board does not display 0.0. 2. Unable to identify iron galvanized, iron powder putty or errors in identification. 3. When you feel that the test data is inaccurate.
      +LinShang LS223+F3N3 Coating Thickness Gauge Big data
        +LinShang LS223+F3N3 Coating Thickness GaugeSimilar products
        +LinShang LS223+F3N3 Coating Thickness GaugeStandard
        +Navigation
        LinShang
        LINSHANG LS223 + F3N3 Portable Coating Thickness Gauge
        Service
        Focus on online sales of Lab Testing Instruments