      MODERNER PPH-750 Combination Pencil Hardness Tester

      MODERNER PPH-750 combination Pencil Hardness Tester conforms to GB/T6739 national standard, with a load of 500g and 750g, PPH Pencil Hardness Tester is used to measure the scratch resistance performance of the paint film surface, using a blue metal shell with a level.

      Brand
      SKU: NB029836
      China Moderner
      Model
      VS
      Genuinegoods
      • Moderner PPH-750 Pencil Hardness TesterOverview

      • Specifications
      • Comments
      • FAQs
      PPH-750
      Pencil Hardness Tester

      PPH-750 Pencil Hardness Tester Overview

      Modern Environment PPH-750 Pencil Hardness Tester is a scratch pencil Hardness Tester used to test the hardness of paint films. There is a level on the surface of the PPH-750 pencil Hardness Tester to ensure that the trolley is in a horizontal state, and it uses a blue metal shell, which has high hardness, good wear resistance, and is not easy to wear. The pencil lead pressure of the PPH-750 pencil Hardness Tester is 750G.

      The PPH-750 pencil Hardness Tester is designed and manufactured with reference to the national standard GB/T6739-2006 "Determination of Paint Film Hardness by Pencil Method for Paints and Varnishes". It provides a fast and economical method to determine the scratch resistance (and other corresponding defects) performance.

      PPH-750 pencil Hardness Tester structure and Principle

      Three points are used to contact the measured surface (two points are the rollers and one point is the pencil lead). The angle between the pencil and the measured surface is 45°. When the horizontal bubble is horizontal, the pressure exerted by the main body on the pencil lead is 750±10 grams. The hardness of a paint film is determined by passing a pencil with a known hardness scale across the paint film.

      MODERNER PPH-750 pencil Hardness Tester details picture 1

      PPH-750 pencil Hardness Tester test steps

      1. Prepare the substrate in accordance with the provisions of GB/T9271 "Standard Test Panels for Paints and Varnishes".

      2. Sharpen the pencil until 5 to 6 mm of the lead is exposed (maintain the cylindrical shape of the lead). Keep the pencil perpendicular to the sandpaper to grind the end face of the lead until the end face becomes a complete circle with no broken or chipped edges. Pencils must be sharpened in this way before each use.

      3. Unless otherwise agreed, the measurement shall be carried out under the conditions of 23±2℃ and 50±5% humidity.

      4. Install the pencil according to the attached figure, push it at least 7 mm at a speed of 0.5~1 mm/second, and use the marked hardness of the hardest pencil that does not cause scratches of 3 mm or more on the paint film to indicate the pencil hardness of the paint film.

      5. Measure twice in parallel. If the results of the second measurement are inconsistent (the difference exceeds 1 pencil hardness unit), the test should be repeated.

      PPH-750 pencil configuration

      Each instrument is equipped with: 13 high-end drawing pencils (6H ~ 6B).

      PPH-750 pencil Hardness Tester maintenance

      1. The PPH-I 750 pencil Hardness Tester strives to rotate flexibly when used. After using it for a period of time, oil must be injected into the rotating parts such as the screw rod and bearings.  

      2. After using the PPH-I 750 pencil Hardness Tester for a period of time, the set screws and nuts must be tightened to avoid loosening.

      Extended reading on pencil Hardness Tester

      Main technical differences before and after the revision of GB/T 6739 standard

      Difference contentCurrent standard GB/T 6739-1996Revised standard
      Procurement statusEquivalent to JIS K 5400 -9 -8.4Equivalent to ISO 15184:1998
      Substrate availableSteel plate, tinplate versionSubstrates that comply with the requirements of GB/T 9271 can be used, such as steel plates, tinplate plates, aluminum plates, wooden boards, etc.
      applied loadInstrumental method: (1000 ±50)gInstrumental method: (750 ±50)g
      pencil hardness number9H, 8H, 7H, 6H, 5H, 4H, 3H, 2H, H, F, HB, B, 2B, 3B, 4B, 5B, 6B9H, 8H, 7H, 6H, 5H, 4H, 3H, 2H, H, F, HB, B, 2B, 3B, 4B, 5B, 6B, 7B, 8B, 9B
      Exposed length of pencil lead3mm5~6mm
      Tools for wiping the paint film surface after testingAdvanced drawing eraserSoft cloth, cotton wool, or drawing eraser


      VS

      Moderner PPH-750 Pencil Hardness TesterSpecifications

      LIST VALUE
      Load 750g+500g
      Applicable standards GB/T 6739-2006
      Standard pencil 6B-6H

      Moderner PPH-750 Pencil Hardness Tester Packing list

      Durometer x1, 13 advanced drawing pencils (6H~ 6B), combined weight 500g/750g

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +Moderner PPH-750 Pencil Hardness Tester Big data
        +Moderner PPH-750 Pencil Hardness TesterStandard
        +Navigation
        Moderner
        MODERNER PPH-750 Combination Pencil Hardness Tester
        Service
        Focus on online sales of Lab Testing Instruments