Adam LPB2602i Electronic Balance 2600g/0.01g
Adam LPB2602i Electronic Balance Maximum range 2600g, readability (d) 0.01g, score n = 260000, minimum weight 0.2g, Repeatability 0.02g, linear + 0.03g, internal calibration.
Adam-
XINYUN FA1204N Analysis Electronic Balance 120g/0.1mg
$ 444.00 -
SDPTOP FB423 Automatic internal calibration Electronic analytical balance Maximum weighing 420g
$ 713.00 -
Seiji AB 2.24 million Electronic Balance Analytical balance 220g/0.1mg
$ 891.00 -
HUAZHI DTT-B6000 Electronic Precision Balance 6000g/0.1g
$ 195.00 -
HUAZHI DTY-C5200 Electronic Balance Weighing: 5200g/10000g
$ 319.00
Luna precision balances offer a wide range of features that make them suitable for most laboratory weighing tasks. Luna's display has a sleek look with easy-to-read 24mm numerals in white on a black background. Luna has text and display capabilities in multiple languages, making it ideal for international use. USB and RS-232 interfaces facilitate data collection and enable smooth communication with printers and computers. The 304-grade stainless steel pot and sturdy ABS plastic construction are easy to keep clean, giving the Luna the rugged durability needed for lab balance.
peculiarity
hardware
Color-coded keys help quickly identify frequently used buttons
The level indicator and adjustable feet ensure proper balance settings for optimal weighing results
Security slot for optional Kensington-type locks and cables to prevent theft
Large 304 stainless steel pots and pans are easy to clean
The sealed keypad protects against dust and spills
USB and RS-232 interfaces allow for fast communication with computers and printers
Software
External calibration allows verification and adjustment by means of weights
The hold function freezes the displayed weight, allowing time to pass without losing results
Multilingual displays are available in many different countries
Use a preset number of samples for part counting
The printout includes the date and time of data tracking in the Good Laboratory Practice (GLP) guidelines
Optional digital filtering for animal/dynamic weighing provides consistent results for objects in motion
Automatically power off to save energy
display
The vivid backlit LCD is easy to see in any lighting condition
power
AC adapter included
Serial models
| Model # | LTB 2602 e / i | LTB 3602 e / i | LTB 4602 e / i | LTB 6002 e / i | |
| Maximum range | 2600 g | 3600 g | 4600 g | 6000 g | |
| readability(d) | 0.01 g | 0.01 g | 0.01 g | 0.01 g | |
| Number of divisionsn= | 260000 | 360000 | 460000 | 600000 | |
| Minimum weight | 0.2 g | 0.2 g | 0.2 g | 0.2 g | |
| repeatability | 0.02 g | ||||
| (Std. Dev) | |||||
| Linear + | 0.03 g | ||||
| Weighing unit | grams, milligrams, carats, grains, Newtons, ounces, troy ounces, Drams, Taels-HK, Taels-T, Taels-S, Mommes, Tolas, Ticals, pennyweight, custom | ||||
| Settling time | Generally 3 second | ||||
| Operating temperature | suggestion15℃ to 35℃Relative Humidity 40 – 60 % RH (No condensation) | ||||
| power supply | External power adapter – Standard | ||||
| (Input Voltage 100–240 VAC, 50/60 Hz) | |||||
| Input Voltage | 18 VDC - 830 mA | ||||
| Weighing Cells | Precision sensor type | ||||
| calibration | suffix i=There is an Internal calibration system,e=Outside schools only | ||||
| Externally calibrated weight | Recommended useOIML F1level orASTM/ANSI 3Grade weights | ||||
| 0.5, 1, 2 kg | 1, 2, 3 kg | 1, 2, 4 kg | 1, 2, 5 kg | ||
| display | Black backlightLCD, 7 characters, 24mm high as well as symbols | ||||
| Draft shield | not | ||||
| (w x d x h) | |||||
| Weighing pan size | square, 185x185 mm | ||||
| Dimensions | 228 x 337 x 108 mm | ||||
| (w x d x h) | |||||
| net weight | e type | 3.6 kg | |||
| i type | 4.6 kg | 4.8 kg | 5.0 kg | 5.0 kg | |
Adam LPB2602i Electronic BalanceSpecifications
| LIST | VALUE |
|---|---|
| Maximum weighing | 2600g |
| Readability | 0.01g |
| Degree n = | 260000 |
| Minimum Weight | 0.2g |
| Repeatability Error | 0.02g |
| Linearity | 0.03g |
| Measurement unit | G, kg, ct, GN, N, dr, lb, oz, lb: oz, ozt, dwt, tl. T, tl. H, tl. S, T, custom unit |
| Stabilization time | 3s |
| operating temperature | Recommended 15℃to35℃, Relative Humidity 40 - 60% RH (non-condensing) |
| Power supply Voltage | External Power Adapter - Standard |
| Power supply Voltage | 18VDC-830mA |
| Weighing Cell | Precision Sensors |
| Adjustment | Internal calibrated |
| test Weight | 0.5, 1, 2kg recommended OIML F1 or ASTM/ANSI 3 Weight |
| monitor | Black backlit LCD, 7 characters, 24mm high, and symbols |
| Wind Shield | none |
| Pan Size | Cube, 185 * 185 mm |
| Dimension | 228*337*108mm |
| Net Weight | 4.6kg |
Adam LPB2602i Electronic Balance Packing list
machine X1, certificate of conformity X1, manual X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Edham Adam Luna series electronic analytical balance models
- How should the calibration weights of precision balances be handled and maintained?
- How to Use the Adams Balance Correctly
- How to choose a precision digital electronic balance?


LPB2602i





