      HONEYEAGLE HNAG1000-NO2 Fixed Nitrogen Dioxide Detector 0-10PPM

      HONEYEAGLE Fixed Nitrogen Dioxide Detector HNAG1000-NO2 is an online NO2 Gas Detector with a range of 0~10ppm. It adopts the special detection principle of flue gas, and is equipped with an infrared remote control as standard. Humidity test value display function.

      Brand
      SKU: NB029948
      China honeyeagle
      Stock
      Loading…
      Price
      $ 582.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • honeyeagle HNAG1000-NO2(0-10PPM) Nitrogen dioxide DetectorOverview

        • Specifications
        • Comments
        • FAQs
        HNAG1000-NO2(0-10PPM)
        Nitrogen dioxide Detector

        Description

        The online sulfur dioxide Gas Detector HNAG1000-SO2 is suitable for real-time and accurate detection of sulfur dioxide concentration and leakage in various environments, using imported electrochemical sensor and microcontroller technology. Fast response, high measurement accuracy, good stability and repeatability. The explosion-proof wiring method is suitable for all kinds of dangerous places, and is compatible with various control alarms, PLC, DCS and other control systems, and can realize on-site alarm and early warning at the same time, 4-20mA standard signal output, relay switching output; It is very good to display various technical indicators and gas concentration values; At the same time, it has a variety of strong circuit protection functions, which can effectively prevent the damage of the instrument caused by various human factors and uncontrollable factors.

        Features

        ●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static ability exceed the national standard, and resist the impact of high-intensity pulse surge current. High reliability and stability.

        ●Standard bus RS485 and 4~20mA standard signal output at the same time, 1 group of relay switching output, optional frequency output 200-1000Hz, Hart protocol signal, 1~5V output, wireless transmission (10-50 km or unlimited distance). It can be wired or wireless remote real-time monitoring, upload the data to the mobile phone or transmit it to the Environmental Protection Bureau, other monitoring centers, monitoring equipment, monitoring computers through the local area network and the Internet, and monitor the concentration of the site in real time through free host computer software or gas alarm controller.

        ●Compatible with various secondary meters, data acquisition modules, PLC, DCS systems, can directly drive solenoid valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays.

        ●Standard infrared remote control, which can realize the operation without opening the lid in dangerous situations, such as: modify alarm point, concentration calibration, zero point calibration, silencer, factory reset, enter the menu,

        ●2.5 inch high-definition color screen (TF) displays real-time concentration, temperature, humidity,

        ●Automatic tracking of zero point to prevent drift, temperature compensation, multi-level calibration, can meet the national standard and local and provincial metrology bureau standards in various regions at the same time.

        Dimensional diagram of sulfur dioxide SO2 online concentration Detector

        Honey Egger HNAG1000-NO2(0-10PPM) Nitrogen Dioxide Detector Details Figure 1

        Place of application

        Petroleum and petrochemical, chemical plants, smelters, iron and steel plants, coal plants, thermal power plants, scientific research, production workshops, tobacco companies, environmental monitoring, school scientific research, building construction, fire alarm, sewage treatment, industrial gas process control, boiler room, garbage treatment plant, tunnel construction, oil pipelines, gas stations, underground gas pipeline maintenance, indoor air quality testing, hazardous place safety protection, aerospace, military equipment monitoring, etc.

        Meets standards

        In line with EMI and EMC standards, it has passed the national standard test and CMC measuring instrument license certification.

        GB 3836.1—2010 General requirements for electrical equipment used in explosive gas atmospheres

        GB 3836.2—2010 Electrical equipment for explosive gas atmospheres - Flameproof type "d"

        GB 3836.4—2010 "Electrical equipment for explosive gas atmospheres – Intrinsically safe type "i"

        VS

        honeyeagle HNAG1000-NO2(0-10PPM) Nitrogen dioxide DetectorSpecifications

        LIST VALUE
        Sensors principle Flue gas only
        Detect gas NO2
        Sampling method Diffusion
        Range 0~10ppm
        Detection Accuracy ±2%F.S
        Repeatability ±1%F.S
        Operating temperature -30~50℃
        Storage temperature -40~70℃
        Operating current ≤50mA
        Installation method fixed installation
        output interface many
        service life 3-5 years
        Baud rate 9600
        Response time <10s
        Environmental humidity 0~95% RH non-condensation
        Long term drift ≤±1%(F.S/年)
        Warm-up time 10s
        Operating Pressure 86kpa-106kpa
        Shell material Aluminum alloy flameproof shell
        Dimensions 183*143*107mm
        Weight 1.5Kg
        Output signal Standard: RS485, 4-20mA
        Sensors brand City
        Power Supply DC5V±1%/DC24±1%
        Accuracy 0.01ppm
        Explosion-proof sign Ex d IIC T6
        Protection level IP66
        LCD display content Measurement of gas name, real-time value, 50-segment histogram display of real-time gas concentration, gas full scale, gas internal parameters
        Analog signal output 3-Wire 4-20mA linear output
        Digital signal output Standard RS485 signal output, with Moden and communication software can communicate with the computer

        honeyeagle HNAG1000-NO2(0-10PPM) Nitrogen dioxide Detector Packing list

        Online Gas detector X1, Infrared remote control X1, Instruction manual X1, Warranty card/certificate X1, Environmental Encasement box X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        To meet the requirements of GB3836.4 nitrogen dioxide detector
        [A]
        HNAG1000-NO2 (0-10PPM) nitrogen dioxide detector, please refer to it.
        [Q]
        The principle of HNAG1000-NO2 (0-10PPM) nitrogen dioxide detector Sensors is dedicated to flue gas?
        [A]
        Yes, the detection principle for flue gas of this model Gas detector. Detect gas NO2
        honeyeagle
        HONEYEAGLE HNAG1000-NO2 Fixed Nitrogen Dioxide Detector 0-10PPM
        Service
        Focus on online sales of Lab Testing Instruments