      Home> Coating Thickness Gauge> PoRuiKe> PoRuiKe BCT-210C(F1) Coating Thickness Gauge

      PORUIKE BCT-210C split high-precision Coating Thickness Gauge F1 probe

      PORUIKE split high-precision Coating Thickness Gauge BCT-210C with magnetic Induction F1 probe, thickness range 0-1250μm, resolution 0.1μm, BCT-210C CHINA Film Thickness Gauge suitable for platings, paints layer, enamel layer, aluminum tile, copper tile, phosphating layer and other thickness measurement, with continuous and single Measurement mode.

      Brand
      SKU: NB029999
      China PoRuiKe
      VS
      PoRuiKeLOGO

      PoRuiKe

      Information
      Genuinegoods
      • PoRuiKe BCT-210C(F1) Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      BCT-210C(F1)
      Coating Thickness Gauge

      Functional use

      Perrick Split High Precision Coating Thickness Gauge BCT-210C can be used for the thickness measurement of electroplating, paint layer, enamel layer, aluminum tile, copper tile, babbitt tile, phosphate layer, paper, and can also be used for thickness measurement of hull paint and adhesion of underwater structure. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.

      Features

      • Full Chinese interface operation, more convenient;

      • This instrument adopts two thickness measurement methods: magnetic and eddy current;

      • It can be equipped with 10 kinds of probes F400, F1, F1/90°, F10, CN02, N1, CN02, N10, F5

      • Limit can be set: the measured value outside the limit can be automatically alarmed, and a batch of measured values can be analyzed by histogram;

      • LCD liquid crystal display, backlight control can be switched on and off;

      • With menu operation;

      • It has the function of communicating with the PC: the measured value and statistical value can be transmitted to the PC for further processing of the data;

      • It has an error prompt function, which can be prompted by screen display or buzzer;

      • There are two shutdown modes: manual shutdown mode and automatic shutdown mode;

      • It is designed with 2 No. 5 batteries, which is easy to replace;

      • It adopts international 9-pin socket and standard USB interface, which can communicate with the host computer through software.

      Coating Thickness Gauge optional probe parameter table

      Probe modelF400F1F1/90F10N1CN02
      Operating Principlemagnetic inductionEddy current
      Measuring range (um)0-4000-12500-100000-1250 (0-40um chrome plating on copper)10-200
      Low Resolution (um)0.10.1100.11
      Indication errorOne Point Calibration (um)±[3%H+1]±[3%H+10]±[3%H+1.5]±[3%H+1]
      Two-point calibration (um)±[(1~3)%H+0.7]±[(1~3)%H+1]±[(1~3)%H+10]±[(1~3)%H+1.5]-
      Measurement conditionsMinimum radius of curvature (mm)Convex 1Convex 1.5Straight103Straight
      Diameter of the minimum area of the substrate (mm)ф3ф7ф7ф40ф5ф7
      Minimum Critical Thickness (mm)0.20.50.520.3Unlimited


      VS

      PoRuiKe BCT-210C(F1) Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle Magnetic Induction
      Measurement range 0~1250μm
      margin of error +/- [3% H + 1] (one point calibrated ); +/- [( 1~ 3) % H + 1] (two point calibrated)
      Resolution 0.1μm
      Minimum measurement surface Φ7mm
      Minimum radius of curvature Convex 1.5mm
      thinnest substrate 0.5mm
      probe Line probe
      Calibrated Certificate none
      Calibrated mode One point calibrated, two point calibrated
      Measurement mode Continuous Measurement mode and Single Measurement mode
      Unit display μm
      statistical function Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
      Interface USB port
      Data storage 500 Measured values
      Power Supply AA (AA) battery
      system language Chinese
      Display screen LCD liquid crystal display
      Operating temperature 0-40℃
      Relative Humidity 20~90%RH
      Connect computer Can connect to computer (optional)
      shutdown mode Manual/Automatic
      Operating Mode Direct mode and group mode

      PoRuiKe BCT-210C(F1) Coating Thickness Gauge Packing list

      BCT-210C host x1, iron-based probe (FE) x1, zero-calibrated base x1, standard test piece x1, AA battery (No. 5) x2, Encasement box x1, operation guide x1, certificate x1, warranty card x1, USB data cable x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Coating thickness gauge conforms to JB/T7663.2 standard?
      [A]
      Coating thickness gauge applies to JB/T7663.2, please consult customer service for detailed application definition
      [Q]
      Hello, what is the minimum measurement area for the BCT-210C Coating thickness gauge probe test?
      [A]
      Hello, the test diameter of the testable sample is not less than 7mm.