Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Transmittance Meter> LinShang> LinShang LS108H Optical inspection transmittance Measurement Instrument
      LinShang LS108H Optical inspection transmittance Measurement Instrument

      LINSHANG LS108H Optical inspection transmittance Measurement Instrument, Lens Glass coating material Tester 1mm test aperture

      The parallel light path design can be used for the measurement of thicker materials; the three Light sources share a test hole, and the 380nm-760nm visible light transmitance, 940nm infrared and 365nm ultraviolet transmittance can be obtained in one measurement.

      Brand
      SKU: NB030005
      China LinShang
      Model
      Stock
      Loading…
      Price
      $ 360.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • LinShang LS108H Optical inspection transmittance Measurement InstrumentOverview

        • Specifications
        • Comments
        • FAQs
        LS108H
        Optical inspection transmittance Measurement Instrument
        • LINSHANG LS108H Optical inspection transmittance Measurement Instrument, Lens Glass coating material Tester 1mm test aperture
        The parallel light path design can be used for the measurement of thicker materials; the three Light sources share a test hole, and the 380nm-760nm visible light transmitance, 940nm infrared and 365nm ultraviolet transmittance can be obtained in one measurement.

        Introduction

        LS108H optical transmittance measuring instrument is a desktop optical transmittance meter, which is professionally used for optical transmittance testing of lenses, glass, coating materials, organic materials, coatings and other substances. The test aperture of the instrument is 1mm, which is suitable for the measurement of light transmittance, infrared and ultraviolet transmittance of small-sized materials. The flat table-top instrument is convenient for placing various test samples, which can be tested immediately after release, and the test data is fast and accurate. Adopting parallel optical path design, it can measure thicker materials.

        The test principle of LS108H optical transmittance Tester is to use ultraviolet light source, infrared light source and visible light source to irradiate the tested transparent material, and the sensor detects the incident light intensity of the three light sources and the light intensity after passing through the tested transparent material, and the transmittance The ratio of the passing light intensity to the incident light intensity is the transmittance, expressed as a percentage.

        Applications

        It is suitable for measuring the transmittance of various uniform and transparent materials, such as glass, PC, coated glass, IR hole on the remote control window, plastic, paint, lens, plexiglass (acrylic), etc.

        Product Dimensions

        Linshang LS108H Optical Transmittance Measuring Instrument Details Figure 1

        Linshang LS108H Optical Transmittance Measuring Instrument Details Figure 2

        Features

        1. The three light sources share one test hole, and the transmittance of 380nm-760nm visible light, 940nm infrared and 365nm ultraviolet can be obtained in one measurement, which is easy to operate and saves time in measurement.

        Linshang LS108H Optical Transmittance Measuring Instrument Details Figure 3

        2. Parallel light design, the measurement results of large thickness materials are also stable and accurate.

        3. The test aperture is 1mm, which can test the transmittance of small-sized materials.

        Linshang LS108H Optical Transmittance Measuring Instrument Details Figure 4

        4. The instrument has real-time dynamic self-calibration function, and it will automatically calibrate to 100% transmittance after starting up.

        5. Suitable for transmittance testing of lenses, coatings, glass, mobile phone lenses, organic materials, etc.

        6. Large liquid crystal display with optional Chinese and English interfaces. Compared with the old instrument, the test data is more intuitive.

        7. Powered by 5V power supply, it is convenient to connect to a mobile power supply (power bank).


        VS

        LinShang LS108H Optical inspection transmittance Measurement InstrumentSpecifications

        LIST VALUE
        Ultraviolet peak wavelength 365nm
        Infrared peak wavelength 940nm
        Peak wavelength of visible light 380~760nm
        resolution 0.1%
        Measurement Accuracy ±2%
        Minimum test size Φ1mm
        Host size 170*180*144mm
        Weight About 1570 grams
        Power DC5V/1A

        LinShang LS108H Optical inspection transmittance Measurement Instrument Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the test aperture of LS108H Transmittance meter measurement?
        [A]
        The LS108H test aperture is 1mm, and the transmittance of visible light in the full wavelength band of 380-760nm is tested.
        [Q]
        What is the lifespan of the LED lamp beads in the light transmitter?
        [A]
        LED lamp beads, the service life given by the manufacturer is 100,000 hours, but due to our use environment, the number of switches and other reasons, the actual use of lamp beads will occur Light intensity attenuation, especially UV Lamp beads, is the most prone to attenuation Light source. Regular use for three to five years is no problem.
        [Q]
        Measurement of light transmitance, the difference between 380-760nm and 550nm
        [A]
        The data of 380-760nm is the transmittance of all wavelengths in the entire range, which conforms to the value calculated by the CIE bright vision function standard. The 550nm light transmitter only tests the transmittance of the 550nm wavelength point.
        [Q]
        After two tests, the transmittance data changes at the same location of the test sample. What's going on?
        [A]
        Before and after the two tests, the change of Measuring location may not be visible to the naked eye, but in fact the location of the test must be slightly different. For materials with uneven transmittance, it is normal for the subtle change of Measuring location to cause the data to change.
        [Q]
        Transmission instrument, remove the sample, the data of the instrument cannot be restored to 100%?
        [A]
        This happens because there is interference from external light in the measurement process, just shut down and restart the instrument, restore to 100%, and then it can be used normally.
        +LinShang LS108H Optical inspection transmittance Measurement Instrument Big data
          +LinShang LS108H Optical inspection transmittance Measurement InstrumentSimilar products
          +LinShang LS108H Optical inspection transmittance Measurement InstrumentStandard
          +Navigation
          LinShang
          LINSHANG LS108H Optical inspection transmittance Measurement Instrument, Lens Glass coating material Tester 1mm test aperture
          Service
          Focus on online sales of Lab Testing Instruments