BOLEL PURIFICATION EQUIPMENT ZJ-TFG-18 ventilated cabinet (external 200mmPVC pipe)
BOLEL PURIFICATION EQUIPMENT ventilating cabinet ZJ-TFG-18 has a purification area size of 1600x700x590mm, suitable for laboratory cleaning and sewage discharge. ZJ-TFG-18 ventilating cabinet is equipped with a 28W lamp.
BOLEL-
BOLEL PURIFICATION EQUIPMENT ZJ-1000 Air Self-Purifier (Ceiling Type)
$ 416.00 -
SuJie VS-1300U double single-sided clean workbench, vertical air supply
$ 1375.00 -
BOLEL PURIFICATION EQUIPMENT SW-CJ-1FD single person vertical Laminar Flow Cabinet (standard type)
$ 646.00 -
Kenton SWP-2 Laminar Flow Cabinet double person level
$ 975.00 -
SuJie SJ-CJ-1BU single-sided clean workbench, horizontal air supply
$ 851.00
Introduction
The fume hood is used in the laboratory, it is necessary to discharge harmful gases, and it is a common laboratory equipment that needs to be cleaned and decontaminated during the test.
Principle
Water, electricity, gas and ventilation all-in-one machine, built-in multi-functional power socket, convenient for using other electrical equipment in the laboratory process. The front baffle is a glass door that can move up and down, and the top is a low-speed exhaust fan, which can smoothly discharge harmful and odorous gases in the experimental filtration, keeping the experimental environment safe and reliable.
Features
The dust-free fireproof high-density board material is used as the frame, and the experimental area is covered with stainless steel.
Good sealing, elegant appearance, firm and durable.
Using LED LCD panel control.
The experimental area is made of stainless steel, and the working area is equipped with a 2KW spare socket, which provides convenience for the operator.
Comparison of parameters of ZJ-TFG fume hood series
| model | ZJ-TFG-12 | ZJ-TFG-15 | ZJ-TFG-18 | ZJ-TFG-900 |
| Dimensions | 1200x750x2000mm | 1500x750x2000mm | 1800x750x2000mm | 900x580x1700mm |
| Purification area size | 1000x700x590mm | 1300x700x590mm | 1600x700x590mm | 750x550x580mm |
| weight | 150kg | 170kg | 200kg | 120kg |
| average wind speed | 0.3~0.6m/s (adjustable) | |||
| power consumption | 0.4kw | 0.6kw | 0.8kw | 0.4kw |
| power supply | 220V50Hz | |||
| flashlight | 21Wx1 | 28Wx1 | 28Wx1 | 14Wx1 |
| Illumination | 300LX | |||
| Exhaust diameter | 200mm | |||
BOLEL ZJ-TFG-18 Ventilating cabinetSpecifications
| LIST | VALUE |
|---|---|
| Dimensions | 1800*750*2000mm |
| Purification area size | 1600*700*590mm |
| Weight | 200kg |
| Average wind speed | 0.3~0.6m/s |
| power consumption | 0.8kw |
| Power | 220V 50HZ |
| Lighting | 28W*① |
| Illumrination degree | 300Lx |
| Exhaust pipe diameter | 200mm |
BOLEL ZJ-TFG-18 Ventilating cabinet Packing list
Ventilating cabinet X1, manual, warranty card, certificate of conformity
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.