TIME2605 dual-use Coating Thickness Gauge 0~1250μm
Magnetic eddy current dual function paints Thickness Gauge, thickness range 0~1250μm, error range +/- (1% H + 1) μm, with zero and multi-point Adjustment, automatic alarm can be set.
TIME-
Germany Nix QNix 4500 + FN3 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-3000μm
$ 957.00 -
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
$ 309.00 -
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
$ 341.00 -
IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
$ 234.00 -
List MEGA-CHEK Master Storage Fast Scan Platings Thickness Gauge
$ 2123.00
product description
Beijing Times dual-purpose coating Thickness Gauge TIME2605 is a portable measuring instrument that can measure the thickness of coatings and coatings quickly, without damage, and accurately. It can be used both in the laboratory and on engineering sites. By using different probes, a variety of measurement needs can be met.
Standards compliant
GB/T 4956â1985 Magnetic method for measuring the thickness of non-magnetic covering layer on magnetic metal substrate
GB/T 4957â1985 Eddy current method for measuring thickness of non-conductive covering layer on non-magnetic metal substrate
JB/T 8393â1996 Magnetic and eddy current coating thickness measuring instrument
JJG 889â95 "Magnetoresistance Thickness Gauge"
JJG 818â93 "Eddy Current Thickness Gauge"
Applications
Beijing Times dual-purpose coating Thickness Gauge TIME2605 can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required by the material protection profession.
Features
Two thickness measurement methods, magnetic and eddy current, are adopted, which can measure the thickness of the non-magnetic covering layer on the magnetic metal substrate and the thickness of the non-conductive covering layer on the non-magnetic metal substrate.
Seven available probes: F1.5, N1.5, F1.5R, FN1.5, F3.5, FN3.5, F10
Automatic recognition of probe: automatically identify iron-based (F), non-ferrous-based (N), dual-purpose type (FN)
Automatically identify the base material: The dual-purpose (FN) probe can automatically identify the base material and perform measurements in the automatic mode;
Multiple calibration methods: zero-point calibration and up to 5-point calibration;
Two measurement methods: single measurement method (SINGLE) and continuous measurement method (CONTINUE);
Two Operating Modes: direct mode (DIRECT) and batch mode (APPL);
Five statistics: average value (MEAN), maximum value (MAX), minimum value (MIN), number of measurements (Times), standard deviation (S.DEV);
Limits can be set: automatic alarm for measured values ââoutside the limits;
Storage: 10,000 measurement values ââcan be stored, with a total of 100 batch groups available;
Data deletion function: You can delete a single suspicious data that appears in the measurement, or delete all data in the storage area to facilitate new measurements;
Data review function: The data in each batch after measurement can be reviewed;
Adjustable screen brightness: The screen brightness is adjustable in 5 levels;
Applications
The instrument is a portable measuring instrument that can measure the thickness of coatings and coatings quickly, without damage, and accurately. It can be used both in the laboratory and on engineering sites. By using different probes, a variety of measurement needs can be met.
TIME TIME2605 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | F:0~1250μm;N:0~1250μm |
| margin of error | ±(1%H+1)μm |
| Resolution | 0.1μm |
| Minimum measurement surface | Φ7mm |
| thinnest substrate | 0.5mm(F);0.3mm(N) |
| Calibrated mode | Zero point calibrated and up to 5 point calibrated |
| Unit display | μm |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Data storage | 10,000 Measured values can be stored with 100 batches available |
| Power Supply | Lithium battery 3.7V 2600mAh rechargeable battery |
| Standards | GB/T 4956-1985、 GB/T 4957-1985、 JB/T 8393-1996、 JJG 889-95、 JJG 818-93 |
| Language | Chinese |
| Display screen | LCD 2.8-inch TFT display, 240 * 320 pixels |
| Operating Conditions | Temperature: 10~30 ℃; Relative Humidity: ≤ 75% RH; no strong magnetic field environment; |
| Machine Weight | About 400g (host) |
| Machine size | 203*92*52mm |
| Working time | About 20 hours |
TIME TIME2605 Coating Thickness Gauge Packing list
host x1, probe x1, manual x1, certificate of conformity x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Application of Coating Thickness Gauge in Automobile Refinish Paint Detection
- Frequently Asked Questions about Coating Thickness Gauge Calibration?
- What is the significance of coating Thickness Gauge calibration? How to calibrate? When to calibrate?
- What is the difference between Magnetic Induction Film Thickness Gauge and eddy Current Film Thickness Gauge?
- Measurement principle of commonly used coating Thickness Gauge
- Principle, Application and Type Selection of Electronic Coating Thickness Gauge
- Defelsko Calibration, Validation and Adjustment
- Application of Paint Coating Thickness Gauge in Measuring Refractory Coating on Steel Pipe
- Three precautions for the use of paint film coating Thickness Gauges
- Film thickness measurement of iron coating
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveISO 2808-2019
- ActiveGB/T 4956-2003
- AbolishGB/T 13448-2006
- AbolishGB/T 4956-1985
- ActiveGB/T 5209-1985
- ActiveQB/T 2183-1995
- ActiveJB/T 9857-2010
- ActiveGB/T 1733-1993
- ActiveGB/T 4957-2003


TIME2605