      Home> Coating Thickness Gauge> TIME> TIME TIME2605 Coating Thickness Gauge

      TIME2605 dual-use Coating Thickness Gauge 0~1250μm

      Magnetic eddy current dual function paints Thickness Gauge, thickness range 0~1250μm, error range +/- (1% H + 1) μm, with zero and multi-point Adjustment, automatic alarm can be set.

      Brand
      SKU: NB030130
      China TIME
      VS
      TIMELOGO

      TIME

      Information
      Genuinegoods
      • TIME TIME2605 Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      TIME2605
      Coating Thickness Gauge
      • TIME2605 dual-use Coating Thickness Gauge 0~1250μm
      • TIME2605 dual-use Coating Thickness Gauge 0~1250μm Figure 1
      • TIME2605 dual-use Coating Thickness Gauge 0~1250μm Figure 2
      Magnetic eddy current dual function paints Thickness Gauge, thickness range 0~1250μm, error range +/- (1% H + 1) μm, with zero and multi-point Adjustment, automatic alarm can be set.

      product description

      Beijing Times dual-purpose coating Thickness Gauge TIME2605 is a portable measuring instrument that can measure the thickness of coatings and coatings quickly, without damage, and accurately. It can be used both in the laboratory and on engineering sites. By using different probes, a variety of measurement needs can be met.

      Standards compliant

      GB/T 4956─1985 Magnetic method for measuring the thickness of non-magnetic covering layer on magnetic metal substrate

      GB/T 4957─1985 Eddy current method for measuring thickness of non-conductive covering layer on non-magnetic metal substrate

      JB/T 8393─1996 Magnetic and eddy current coating thickness measuring instrument

      JJG 889─95 "Magnetoresistance Thickness Gauge"

      JJG 818─93 "Eddy Current Thickness Gauge"

      Applications

      Beijing Times dual-purpose coating Thickness Gauge TIME2605 can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. It is an instrument required by the material protection profession.

      Features

      • Two thickness measurement methods, magnetic and eddy current, are adopted, which can measure the thickness of the non-magnetic covering layer on the magnetic metal substrate and the thickness of the non-conductive covering layer on the non-magnetic metal substrate.

      • Seven available probes: F1.5, N1.5, F1.5R, FN1.5, F3.5, FN3.5, F10

      • Automatic recognition of probe: automatically identify iron-based (F), non-ferrous-based (N), dual-purpose type (FN)

      • Automatically identify the base material: The dual-purpose (FN) probe can automatically identify the base material and perform measurements in the automatic mode;

      • Multiple calibration methods: zero-point calibration and up to 5-point calibration;

      • Two measurement methods: single measurement method (SINGLE) and continuous measurement method (CONTINUE);

      • Two Operating Modes: direct mode (DIRECT) and batch mode (APPL);

      • Five statistics: average value (MEAN), maximum value (MAX), minimum value (MIN), number of measurements (Times), standard deviation (S.DEV);

      • Limits can be set: automatic alarm for measured values ​​outside the limits;

      • Storage: 10,000 measurement values ​​can be stored, with a total of 100 batch groups available;

      • Data deletion function: You can delete a single suspicious data that appears in the measurement, or delete all data in the storage area to facilitate new measurements;

      • Data review function: The data in each batch after measurement can be reviewed;

      • Adjustable screen brightness: The screen brightness is adjustable in 5 levels;

      Applications

      The instrument is a portable measuring instrument that can measure the thickness of coatings and coatings quickly, without damage, and accurately. It can be used both in the laboratory and on engineering sites. By using different probes, a variety of measurement needs can be met.


      VS

      TIME TIME2605 Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle Magnetic Induction + eddy Current
      Measurement range F:0~1250μm;N:0~1250μm
      margin of error ±(1%H+1)μm
      Resolution 0.1μm
      Minimum measurement surface Φ7mm
      thinnest substrate 0.5mm(F);0.3mm(N)
      Calibrated mode Zero point calibrated and up to 5 point calibrated
      Unit display μm
      statistical function Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
      Data storage 10,000 Measured values can be stored with 100 batches available
      Power Supply Lithium battery 3.7V 2600mAh rechargeable battery
      Standards GB/T 4956-1985、 GB/T 4957-1985、 JB/T 8393-1996、 JJG 889-95、 JJG 818-93
      Language Chinese
      Display screen LCD 2.8-inch TFT display, 240 * 320 pixels
      Operating Conditions Temperature: 10~30 ℃; Relative Humidity: ≤ 75% RH; no strong magnetic field environment;
      Machine Weight About 400g (host)
      Machine size 203*92*52mm
      Working time About 20 hours

      TIME TIME2605 Coating Thickness Gauge Packing list

      host x1, probe x1, manual x1, certificate of conformity x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Do you have the Coating thickness gauge involved in GB/T1733?
      [A]
      The TIME2605 Coating thickness gauge will do
      +TIME TIME2605 Coating Thickness Gauge Big data
        +TIME TIME2605 Coating Thickness GaugeSimilar products
        +TIME TIME2605 Coating Thickness GaugeKnowledge
        +TIME TIME2605 Coating Thickness GaugeStandard
        +Navigation
        TIME
        TIME2605 dual-use Coating Thickness Gauge 0~1250μm
        Service
        Focus on online sales of Lab Testing Instruments