CHINA ASR-408E Thermal Shock Test Chamber High and Low Temperature Impact Tester
CHINA Thermal Shock Test Chamber ASR-408E Yes, the Test Chamber size is 60x85x80cm. It is an experimental Thermal Shock Test Chamber. It adopts touch operation and is suitable for testing metals, rubber, electronics and other materials.
AISRY-
ZKHS WDCJ-162B high and low temperature impact test chamber, circulating hot and cold test chamber -40 ℃~ 150 ℃
$ 24400.00 -
China domestic (CN) NBC-150E Thermal Shock Test Chamber High and Low Temperature Impact Tester
$ 14015.00 -
FARUI FR-1219-150 (-40 ℃) triple-channel Thermal Shock Tester
$ 19487.00 -
KESIONOTS Precision Thermal Shock testing device KS-OTS-LR150LC Low temperature -65 ℃/150L
$ 23265.00 -
KESIONOTS Electronic Thermal Shock Tester KS-OTS-LR80LC Low Temperature -65 ℃/80L
$ 19954.00
Introduction
Thermal shock testing machine is used to test material structures or composite materials through a continuous ring of extremely high-low temperatures in an instantThe degree to which it can tolerate in order to test the chemical changes or physical injuries caused by its thermal expansion and contraction in the shortest possible time.
Applicable objects include metals, plastics, rubber, electronics... and other materials, which can be used as the basis or reference for the improvement of its products.
Features
The Three-Chamber equipment is divided into three parts: high temperature area, low temperature area and test area, and the test product is placed in the test area and the high temperature area during impactOr the temperature of the low temperature zone rushes into the test area for impact, and the test product is static.
The touch-sensitive graphical operation interface is easy to operate.
The impact mode uses the air path switching mode to enter the temperature channel into the test area for cold and thermal shock testing.
In the case of high temperature impact or low temperature impact, the maximum time can reach 999 hours, and the maximum cycle time can reach 9999 times.
The system can be used as an automatic recirculating engine or manual selective impact, and can set the second or third zone impact and the start of cold, heavy and hot impulse.
The cooling adopts a binary refrigeration system, the cooling effect is fast, and the cooling method is water-cooled.Light can be tested to impact room temperature
Perform and meet standards and test methods
1. GJB150.5 temperature shock test, 2. GJB360.7 temperature shock test, temperature shock test, 3. GB/T2423.22
Comparison of parameters of thermal shock Test Chamber series
| Model | ASR-50E | ASR-80E | ASR-150E | ASR-225E | ASR-408E |
| Inner Dimensions (cm) | 36x35x40 | 36x35x40 | 60x50x50 | 50x75x60 | 60x85x80 |
| Exterior Dimensions (cm) | 138x180x155 | 150x190x160 | 190x200x195 | 210x220x205 | 225x250x220 |
| Temperature range | -60℃~150℃ | ||||
| Temperature fluctuations | ±2℃ | ||||
| Temperature error | ±2℃ | ||||
| Cooling method | Air-cooled/water-cooled | ||||
| Refrigerant | Environmentally friendly refrigerant HFC | ||||
| Control mode | Microcomputer control + PID + SSR | ||||
| Interior and exterior materials | SUS304# good stainless steel | ||||
| Safety devices | Overheat protection, compressor overload protection device, control system overload protection, high-low Voltage protection switch | ||||
| power supply | AC 380V, 3 phase, 5 wires | ||||
AISRY ASR-408E Thermal Shock Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Liner size | 600*850*800mm |
| Dimensions | 225*250*220cm |
| Temperature range | -60~150℃ |
| Temperature Fluctuation | ±2℃ |
| temperature error | ±2℃ |
| Refrigeration system | Air-cooled/water-cooled |
| refrigerant | Environmentally friendly refrigerant HFC |
| Control mode | Microcomputer control + PID + SSR |
| Enclosure Material | SUS #304 stainless steel plate |
| Protection device | Overheating protection, compressor overload protection device, Control system overload protection, high and low Voltage protection switch |
| Power supply Voltage | AC 380V, 3-phase, 5-wire |
AISRY ASR-408E Thermal Shock Test Chamber Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Hot melt adhesive testing instrument scheme for sanitary napkins [in line with HG/T 3948]
- Lithium-ion battery separator performance testing scheme [with instrument list]
- Paper tear Tester operating instructions
- ASR-XJJ-11B Digital Display Cantilever Impact Testing Machine Operation Manual
- ASR-MFY-02 Vacuum Sealing Performance Tester Instruction Manual
- ASR-8516 Single Wing Drop Testing Machine Operation Manual
- Operation Manual of Asiri Taber Wear Tester
- ASR-5608 Electric Pencil Hardness Tester Operation Manual
- ASR-5622 Electric Decolorization Testing Machine Operation Manual
- Asiri Simulates Automobile Transportation Shaker Operation Manual
- ActiveGB/T 7991.3-2021
- ActiveGB/T 2423.22-2012
- ActiveGJB 150.5a-2009
- ActiveGJB 150.5-1986
- ActiveGB/T 2423.22-2002


ASR-408E