LEPTO CC-2008EW Viscometer Special Thermostatic Circulator -20~100 ℃ Hot and Cold Economical
Temperature range -20~100 ℃, Temperature fluctuation ± 0.05~ 0.1 ℃, temperature resolution 0.1 ℃, temperature transducer Pt100, working tank volume 8L, slot opening size 175 * 145 * 150mm, pump flow 12L/min
labtop-
HLC-1008G Vertical High and Low Temperature Thermostat
$ 1485.00 -
YIHENG CU-600 (DK-600A) electrothermal Thermostatic Water Bath Input Power is 1000W
$ 295.00 -
SANFA DK-8D Electric thermostatic Three hole sink 3X2L
$ 397.00 -
SDPTOP DCY-4015 Low Temperature Thermostat -40~95 ℃/15L
$ 3429.00 -
Shangtian Jingyi DC-0520 Low Temperature Thermostatic Bath Circulating thermostatic bath -5 ℃/20L
$ 1575.00
Product specialdot
1. Compact appearance, small size, very convenient to place on the desktop;
2. With external temperature control and programmable function, it can realize automatic heating, constant temperature and cooling test of the sample during the test
3. It can be controlled by 10 stages of program to achieve the requirements of regular constant temperature, heating and cooling;
4. When used with viscometer, the operation part of the high-low temperature thermostat circulator and the operation part of the viscometer are oriented to the operator, the operation and display of the two instruments are very convenient, and the test process and data are clear at a glance;
5. Two kinds of elevated racks are standard, suitable for different volumes of sample cups;
6. Two insulation pipes are standard to facilitate the user to carry out the constant temperature viscosity test of the outer circulation Water Bath jacket;
7. It has heating and cooling functions at the same time, and can easily achieve precise control of any temperature between -10°C and 220°C;
8. The low-level buoy provides a low-level alarm to prevent dry burning, and can be reminded by light and sound at the same time.
9. Maintenance-free pressure/suction pump, with strong pump power, the pump can stir the bath liquid in the tank horizontally and vertically at the same time, the temperature uniformity in the tank is good, and the application of internal circulation and external circulation can be carried out, and the test can also be carried out on the desktop when the machine is placed on the ground during the external circulation;
10. Large opening design, the container can be directly placed in the tank for reaction, or the test tube rack can be placed in the tank first, and then multiple test tubes can be placed on the test tube rack for sample constant temperature reaction
11. The pump pressure and flow rate automatically adapt to the external load, the international standard M16x1 connection nut, different joints can be configured to meet the needs of different external circulation pipe diameters;
12. The parts in contact with liquid or steam are made of high-performance stainless steel and high-performance plastic, which are corrosion-resistant and do not form scale;
13. Fluorine-free and environmentally friendly refrigerant;
14. A variety of operation modes are optional, and the unexpected power failure can be automatically restored;
15. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control the start and stop of the equipment;
16. Optional 0-10V or 4-20mA analog signal input, which can be used for the start and stop of external intelligent equipment control instruments;
Applications
1. The rotameter, rotary viscometer, and cone plate viscometer are tested for sample viscosity in the bath.
2. The rotameter, rotary viscometer, and cone plate viscometer are tested for sample viscosity in a Water Bath jacket outside the bath.
3. Temperature control of high-low temperature reaction process in the tank.
Quality control, such as calibration of temperature sensors, etc.
Series selection
| Model | Temperature range | Heating power | Bath volume |
| CC-1008EW | -10~100 | 2Kw | 8L |
| CC-2008EW | -20~100 | ||
| CC-1008W | -10~150 | ||
| CC-2008W | -20~150 | ||
| VTC12 | (-20)20~100 | 12L | |
| VTC18 | (-20)20~100 | 18L | |
| VTC26 | (-20)20~100 | 26L |
labtop CC-2008EW Thermostatic circulatorSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~100℃ |
| Temperature fluctuation | ±0.05~0.1℃ |
| temperature resolution | 0.1℃ |
| Temperature transducer | Pt100 |
| Tank Volume | 8L |
| Tank opening Dimensions | 175*145*150mm |
| Pump flow | 12L/min |
| Power | 200~230 VAC/50Hz |
| Dimensions | 415X410X426mm |
| Temperature display | TFT |
| Heating power | 2000W |
| Pump connection interface | M16x1 |
| Instrument fixing method | desktop |
| Allowable environment temperature | 5~32℃ |
| Allowable Relative Humidity | 80% |
labtop CC-2008EW Thermostatic circulator Packing list
L Constant temperature circulating water bath x1, beaker bracket one x1, beaker bracket two x1, thermal insulation pipe 1.8 meters x2, operation manual x1, certificate x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Learn how to choose a Lepto thermostatic circulator in one article
- Nine Operation Precautions for Hot and Cold Cycle Impact Test Chamber
- How to use an environmental Test Chamber for rust resistance and durability testing of metal coatings?
- Thermostatic bath working principle and its application in viscosity measurement
- Comparison of 3 viscosity measurement methods: capillary method, rotation method, falling ball method
- What are the specific requirements for rheology of latex paint?
- Basic concepts, principles and measurement methods of viscosity
- The relationship between paste ink and viscosity (viscosity)
- Thixotropic Cracking Coefficient Method for Determination of Ink Rheology
- What are Newtonian and non-Newtonian fluids?
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 26809-2011
- ActiveGB/T 32710.3-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011
- ActiveJB/T 5376-1991
- AbolishGB/T 11175-2002


CC-2008EW