LEICI JPB-607A Portable Dissolved Oxygen Meter
LEICI portable Dissolved Oxygen Meter JPB-607A adopts liquid crystal display, with automatic temperature compensation function, JPB-607A supports zero oxygen calibrate, fullness calibrate and salinity calibrate, suitable for environmental protection, sewage treatment and other water dissolved oxygen measurement.
LeiCi-
Qiwei TZL-1 Benchtop Total Phosphorus Tester
$ 274.00 -
TONGAO TR 6900DZ Desktop multiparameter STIP-scan
$ 4703.00 -
DDKSIC PO10 portable pH, ORP meter (color screen) pH/ORP/℃
$ 545.00 -
Bante DO-8 portable Dissolved Oxygen Meter with US DO100 dissolved Oxygen electrode
$ 427.00 -
HANNA HI2020 edge large screen flat panel pH & pH-mV Tester
$ 885.00








Introduction
JPB-607A portable dissolved oxygen Tester is equipped with dissolved oxygen electrode, which can be used for the determination of dissolved oxygen in water by tap water source monitoring, aquaculture farms, environmental protection, sewage treatment plants, beverage industry and scientific research units.
Features
LCD display, blue backlight optional;
Automatic temperature compensation, fast response time;
Supports zero-oxygen calibration, full-level calibration, and salinity calibration;
Portable design, easy to carry.
LeiCi JPB-607A Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| Dissolved oxygen range | (0.00~20.00)mg/L |
| Minimum resolution | 0.01 mg/L |
| Dissolved oxygen electron unit error of indication | ±0.10mg/L |
| Instrument error of dissolved oxygen indication | ±0.30mg/L |
| Response time | ≤ 45s (90% Response at 20.0 ° C) |
| Salinity compensation error | ±2% |
| Minimum resolution | 0.1% |
| Saturation error of electronic unit indication | ±2.0% |
| An indication of instrument error | ±10.0% |
| Temperature range | (-5.0~110.0)℃ |
| Temperature minimum resolution | 0.1℃ |
| Electronic unit error of indication | ±0.2 ℃ |
| An indication of an error of instrument | +/- 0.4 ° C (0.0 ° C -60.0 ℃); +/- 1.0 ° C (Miscellaneous range) |
| Power Supply | Rechargeable lithium battery, power adapter (input: AC100~240V, output: DC5V) |
| Size (mm), Weight (kg) | 80×225×35 ,0.4 |
LeiCi JPB-607A Dissolved Oxygen Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The principle and main functions of STIP-scan
- Definitions for Conductivity, Resistivity, TDS and Salinity Measurements
- Ren's JENCO 9010M dissolved Oxygen Meter instruction manual
- What type of electrode can be used to measure dissolved oxygen?
- ANLELIS DO300 Portable dissolved Oxygen Meter Concise operation guide
- Introduction to STIP-scan function and principle
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022


JPB-607A