LEICI DZB-715 Portable in situ STIP-scan
LEICI DZB-715 Portable in situ STIP-scan instrument grade pH: 0.1; conductivity: 1.0; dissolved oxygen: +/- 0.30mg/L, Measurement parameters pH, ORP, conductivity, salinity, dissolved oxygen (film laminating type), temperature, depth.
LeiCi-
LEICI 782500N02 Total Nitrogen Working Reagent Kit for DGB-401
$ 158.00 -
HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
$ 540.00 -
TONGAO TR-105H Water Quality Hexavalent Chromium Tester
$ 786.00 -
TONGAO TR-408ZH multiparameter water quality monitor
$ 4703.00 -
DDKSIC PC1 pen multiparameter analyzer pH mV (ORP electrode optional) conductivity resistivity TDS salinity ℃
$ 215.00
DZB-715 portable in-situ water quality monitor, composed of handheld control terminal, cable, measuring terminal, intelligent electrode, etc., using intelligent multi-parameter digital sensor, can obtain accurate location and depth information of the detection point, can be put into the river, lake reservoir and river assessment section of the sea to carry out in-situ monitoring of pH, conductance, dissolved oxygen, ORP, water temperature, water depth, applicable water depth up to 10 meters, to avoid water quality changes in the process of sampling and transmission. The whole set of instruments can be traced from the detection point, instrument calibration, detection and storage, and uploading.












Features
●Measurable parameters include pH, ORP, conductivity, salinity, dissolved oxygen, temperature, depth, pressure;
●Equipped with multi-parameter digital sensor and patented deep-water stirring electrode, and different digital electrodes such as PH, conductivity, and ORP can be selected according to needs;
●Using the new microprocessor technology, customized 3.5-inch TFT touch screen, up to 65k color gamut, translucent material, suitable for field use;
●Single-point measurement or continuous measurement with automatic stabilization function;
●Support single-point or multi-point calibration;
●Support measurement section ID management, GPRS function and automatic data upload function, and can also set a variety of reference conditions to check the experimental results;
●Support GLP specification, large-capacity memory storage (5000 groups), can realize direct transmission of in-situ data to the management platform;
● Global Positioning System (GPS) (optional), which can store measurement data and station coordinates;
●Support electrode correction function, firmware upgrade function and portable instrument power consumption management function, etc.;
●The cable length is standard 10m, and the longest is 100m (need to be customized);
●With USB, RS485 interface, connected with PC, charging power supply, can also be managed and analyzed by software;
● The software can be upgraded by PC;
●Long-life rechargeable lithium battery power supply host;
●IP67 waterproof at the measuring end, IP65 for the handheld terminal;
●Portable test box design, complete accessories, easy to carry to the site for measurement. Distributed capacitive touch pen for easy use with gloves in the field.
LeiCi DZB-715 STIP-scanSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | pH: 0.1 grade; conductivity: 1.0 grade |
| Measurement parameter | pH, ORP, conductivity, dissolved oxygen, temperature, depth |
| pH range | (0.00~14.00)pH |
| Minimum resolution | 0.01pH |
| Electronic unit error of indication | ±0.10pH |
| ORP range | (-1999.9-1999.9)mV |
| Minimum resolution | 0.1mV |
| Electronic unit error of indication | ±20.0mV |
| Conductivity range | 0μS/cm~200mS/cm |
| Minimum resolution | 0.001μS/cm |
| Electronic unit error of indication | ±1.00%FS |
| Dissolved oxygen range | (0.00~19.99)mg/L |
| Minimum resolution | 0.01mg/L |
| Electronic unit error of indication | Dissolved oxygen concentration : +/- 0.30 mg/L; dissolved oxygen saturation : +/- 1 0.0% |
| Temperature range | (-5.0~70.0)℃ |
| Minimum resolution | 0.1℃ |
| Electronic unit error of indication | ±0.5℃ |
| depth range | (0.00~10.00)m |
| Minimum resolution | 0.01m |
| Electronic unit error of indication | ±0.05m |
| Size (mm), Weight (kg) | 90×235×56,0.3 |
LeiCi DZB-715 STIP-scan Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- STIP-scan working principle, use method, application field
- What are the factors considered in STIP-scan selection?
- Application of STIP-scan in fish pond water quality detection
- Eight Routine Test Indicators for Well Water Quality Testing
- Application of Water Quality Analyzer in Swimming Pool Water Quality Detection
- Water quality testing routine 9 indicators
- ActiveJJG 2104-2024
- ActiveHJ 1147-2020
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022
- ActiveGB/T 17650.2-2021


DZB-715