LEICI WZS-186 Turbidity Meter 2000NTU
LEICI WZS-186 Turbidity Meter Measurement range (0~20.00) NTU, (20.0~200.0) NTU, (200~2000) NTU, error of indication does not exceed +/- 6%, Repeatability does not exceed 0.5%, Stability does not exceed +/- 0.5% FS/30 minutes
LeiCi-
INESA WGZ-2000B Portable Turbidity Meter
$ 770.00 -
Qiwei ZD-501 Portable Turbidity Meter
$ 271.00 -
JINGQI WGZ-1000BJ Portable precision low turbidity instrument
$ 770.00 -
Yuefeng SGZ-1000I Microcomputer Turbidity Meter 1000NTU/0.01
$ 677.00 -
INESA INESA WGZ-4000 desktop Turbidity Meter 4000NTU
$ 1097.00
WZS-186 Turbidity Meter is designed according to the principle of scattering-transmitted light measurement, using LED stable light source, in line with ISO7027 standards; It has the functions of automatic color compensation and automatic range switching.









Features
LED light source, which meets ISO7027 standards;
Scattered-transmitted light measurement principle, automatic color compensation;
Automatic range switching;
Supports zero and up to 7 point calibration;
Support for averaging measurement to compensate for reading fluctuations due to random drift of suspended solids in the sample through averaging calculations;
Comply with GLP specifications, support data access and deletion, and store up to 2000 sets of data;
It has a standard USB communication interface and supports connection with PC;
It has the function of power-off protection.
LeiCi WZS-186 Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Light source | 860nm LED |
| Measurement range | (0.000~9.999)NTU(10.00~99.99)NTU(100.0~999.9)NTU(1000~2000)NTU |
| resolution | 0.001/0.01/0.1/1 NTU |
| error of indication | ±6% |
| Repeatability | ≤0.5% |
| Zero drift | ±0.5% FS/30min |
| Stability | ±0.5%FS/30min |
| calibrate | Zero and up to 7 points (2, 20, 50, 200, 500, 1000, 2000 NTU) |
| data storage | 2000 |
| Display | 7-Inch color touch LCD screen |
| Standard long-lasting turbidity calibrated set specifications | 20/200/500/1000/2000NTU |
| Protection level | IP54 |
| Operating Environment | Environmental temperature: (5~ 35) ℃ Relative Humidity: not more than 85% |
| Power Supply | Power adapter (input: AC100~240V output: DC24V, not less than 0.7A) |
| Size (mm), Weight (kg) | 189 × 282 × 84, about 1.5 |
LeiCi WZS-186 Turbidity Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Why is silicone oil important in turbidity meter measurements?
- How to verify the photoelectric Turbidimeter?
- What is a turbidity meter and how does it work?
- Turbidity Meter/Turbidity Sensor FAQ
- How to measure the turbidity of a liquid?
- Water quality testing instrument FAQ collection
- What is haze or turbidity?
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991


WZS-186