LEICI WZS-181A Turbidity Meter 200NTU
WZS-181A Turbidity Meter Measurement range (0~20.00) NTU, (20.0~200.0) NTU, error of indication does not exceed +/- 6%, Repeatability does not exceed 0.5%, Stability does not exceed +/- 0.5% FS/30 minutes
LeiCi-
INESA WGZ-200B Portable Turbidity Meter 200NTU
$ 444.00 -
Yuefeng SGZ-4000I Microcomputer Turbidity Meter 4000NTU/0.01
$ 1097.00 -
Yuefeng SGZ-50B LABOratory Turbidity Meter measuring range 0~50NTU/0.01
$ 260.00 -
HANNA HI88713 Microcomputer multi-range Turbidimeter (ISO standard)
$ 3124.00 -
JINGQI WGZ-400BJ Portable precision low turbidity instrument
$ 613.00
The WZS-181A Turbidity Meter adopts the principle of scattered-transmitted light measurement with automatic color compensation. It can be widely used in the turbidity detection of surface water, industrial water, drinking water, beverages, landscape water, swimming pool water, wastewater and other samples.









Features
LED light source, which meets ISO7027 standards;
Scattered-transmitted light measurement principle, automatic color compensation;
Automatic range switching;
Supports zero and up to 4 point calibration;
Support for averaging measurement to compensate for reading fluctuations due to random drift of suspended solids in the sample through averaging calculations;
Comply with GLP specifications, support data access and deletion, and store up to 200 sets of data;
It has a standard USB communication interface and supports connection with PC;
It has the function of power-off protection.
LeiCi WZS-181A Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~20.00NTU、20.0~200.0NTU |
| Error of indication | ≤±6% |
| Repeatability | ±0.5%F.S |
| Stability | No more than +/- 0.5% FS/30 minutes |
| Power supply Voltage | AC(220±22)V,(50±1)Hz |
| Dimensions | 250*95*60mm |
| Weight | 0.4kg |
LeiCi WZS-181A Turbidity Meter Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What is haze or turbidity?
- How to verify the photoelectric Turbidimeter?
- Water quality testing instrument FAQ collection
- How to measure the turbidity of a liquid?
- Turbidity Meter/Turbidity Sensor FAQ
- What is a turbidity meter and how does it work?
- Why is silicone oil important in turbidity meter measurements?
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991


WZS-181A