LEICI DZB-718L-A multiparameter analyzer for pH/pX and conductivity
The LEICI DZB-718L-A portable multiparameter analyzer comes standard with a pH/pX module and a conductivity module, using a TFT touch display. The DZB-718L-A has a pH/pX level of 0.001 and a conductivity level of 0.5.
LeiCi-
DDKSIC ODO01-3M Optical inspection type dissolved Oxygen electrode monitors oxygen content in water without consuming oxygen in water and without frequent diaphragm replacement
$ 586.00 -
HANNA HI98195 10-parameter water quality analysis Tester 40 meters long
$ 2828.00 -
LEICI 782500N02 Total Nitrogen Working Reagent Kit for DGB-401
$ 158.00 -
HANNA HI9829-10042 high-precision multiparameter Water Quality Analyzer GPS pH/ORP/EC/DO 4m probe 230V
$ 6078.00 -
LEICI CO-572 Chemical Oxygen Demand Tester
$ 1535.00








Features
● High-definition color LCD touch screen, clear display
● Support Chinese and English
● Temperature units are optional: °C and °F
● Support self-diagnosis, automatic shutdown, power-off protection and factory reset functions
● Support firmware upgrade function, allowing function expansion and personalized requirements
● Support IP65 protection level
● Triple composite pH electrode, composite conductivity electrode, polarographic dissolved oxygen electrode, electrode hanger, silicone protective case, wristband, portable carrying case and calibration solution are standard
One machine for multiple purposes
● Built-in pH/pX, conductivity, dissolved oxygen 3 measurement units
● Test items: pH/pX value, ion concentration, mV value, conductivity, resistivity, TDS, salinity, gray scale, dissolved oxygen, dissolved oxygen saturation, temperature
Intelligent detection and automatic identification
● Intelligent operating system, with functions such as method management, electrode management, data management and user management
● Support user hierarchical authority management and password management
● Intelligent endpoint discrimination, support automatic reading, timed reading, timed interval reading, and manual reading
● It has the function of calibration reminder and alarm
Data management, information traceability
● Support data storage (1000 sets each), statistics, analysis, review, deletion, and transmission
● Comply with GLP to achieve data traceability and statistical analysis
● With USB interface, it can be connected with PC through special communication software to achieve data transmission; Support U disk reading and writing; Scanner support
● Built-in Bluetooth, support wireless transmission
pH/ion measurement function
● Automatically identify 6 groups of buffer solutions such as GB, DIN, NIST, USA, MERK, and JIS, and support custom standard solutions and standard solution groups
● Support 1-8 points of pH electrode or ion electrode calibration, 1 point ORP electrode calibration
● Built-in Na+, K+, NH4+, Cl-, F- and other ion modes, allowing users to build their own
● Rapid switching of μg/L, mg/L, g/L, mol/L, mmol/L, PX and other ion concentration units
● Measurement mode: direct reading concentration measurement, standard addition measurement, sample addition measurement, GRAN measurement
Conductivity measurement function
● Within the range of measuring range, it has the functions of automatic temperature compensation and automatic range switching
● Automatic identification of GB and international standard conductivity solutions, support 1-5 points of conductivity electrode calibration
● Support a variety of conductivity compensation methods such as uncompensated, linear, and pure water compensation
● Reference temperature 5.0°C, 10.0°C, 15.0°C, 18.0°C, 20.0°C and 25.0°C are optional, default 25°C
● Support automatic frequency switching, supporting 1.0 constant electrode can cover full-scale measurement (0.1 constant or 0.01 constant conductivity electrode is recommended for samples below 20μS/cm)
Dissolved oxygen measurement function
● Support automatic temperature compensation, automatic atmospheric pressure compensation (units can be selected kPa, mbar, Torr, Atm)
● Support zero oxygen calibration and full calibration
● Support manual salinity compensation function
power management
● Powered by large-capacity lithium battery, it supports charging by connecting PC and power bank
● It has the function of battery under-Voltage reminder and charging status reminder
● Support backlight adjustment
LeiCi DZB-718L-A STIP-scanSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | pH/pX, potential, Ion concentration, temperature, conductivity, resistivity, TDS, salinity |
| Power Supply | Rechargeable lithium battery (DC 3.8V) |
| Dimensions | 201*96*55mm |
| Weight | 0.3kg |
| Instrument level | pH/pX module: level 0.001; Conductivity Detector module: level 0.5 |
| pH/pX Measurement range | (-2.000~20.000)pH;(0.000~14.000)pX |
| Ion concentration Measurement range | (0~19990), unit mol/L, mmol/L, g/L, mg/L, μg/L |
| Conductivity range | 0.000μS/cm~3000mS/cm |
| Resistivity range | 5.00Ω.cm~100.0MΩ.cm |
| TDS range | 0.000mg/L~300g/L |
| Salinity range | 0.00~8.00% |
| Measurement range | (-5.0~130.0)℃ |
| pH/pX resolution | 0.001pH/pX;0.01pH/pX |
| mV resolution | 0.01 mV,0.1mV |
| Ion concentration resolution | Five significant digits (expressed in scientific notation) |
| EC resolution | 0.001μS/cm |
| Resistivity resolution | 0.001Ω·cm |
| TDS resolution | 0.001mg/L |
| Salinity resolution | 0.01% |
| Temperature Resolution | 0.1℃ |
| pH/pX intrinsic error | ±0.002pH/pX |
| mV intrinsic error | +/- 0.1mV or +/- 0.03% |
| Ion concentration intrinsic error | ±0.3% |
| EC intrinsic error | ±0.5%FS |
| Resistivity intrinsic error | ±0.5%FS |
| TDS intrinsic error | ±0.5%FS |
| Salinity intrinsic error | ±0.1% |
| Temperature intrinsic error | ±0.1℃ |
LeiCi DZB-718L-A STIP-scan Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the factors considered in STIP-scan selection?
- Eight Routine Test Indicators for Well Water Quality Testing
- Application of STIP-scan in fish pond water quality detection
- Application of Water Quality Analyzer in Swimming Pool Water Quality Detection
- STIP-scan working principle, use method, application field
- Water quality testing routine 9 indicators
- Basic knowledge of conductivity, resistivity, TDS and salinity measurements
- ActiveJJG 2059-2014
- Active 126-2009
- ActiveHJ 1147-2020
- ActiveSL 144.2-2008
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022
- ActiveGB/T 17650.2-2021


DZB-718L-A