      LABTOP icooler- 4006 low temperature chilled down liquid circulating machine -40 ℃/4.5L

      Temperature range -40~ RT ℃, Temperature Fluctuation +/- 0.3 +/- K, Temperature display LED, Display accuracy 0.1 ℃, Temperature Control mode Intelligent PID, temperature sensor PT 100, Cooling capacity (20 ℃) 800W, Sink volume 6L

      Brand
      SKU: NB030746
      China labtop
      VS
      Genuinegoods
      • labtop icooler-4006 Low temperature chilled down liquid circulatorOverview

      • Specifications
      • Comments
      • FAQs
      icooler-4006
      Low temperature chilled down liquid circulator
      • LABTOP icooler- 4006 low temperature chilled down liquid circulating machine -40 ℃/4.5L
      • LABTOP icooler- 4006 low temperature chilled down liquid circulating machine -40 ℃/4.5L Figure 1
      • LABTOP icooler- 4006 low temperature chilled down liquid circulating machine -40 ℃/4.5L Figure 2
      Temperature range -40~ RT ℃, Temperature Fluctuation +/- 0.3 +/- K, Temperature display LED, Display accuracy 0.1 ℃, Temperature Control mode Intelligent PID, temperature sensor PT 100, Cooling capacity (20 ℃) 800W, Sink volume 6L

      Introduction

      iCooler low-temperature coolant Circulating Chiller, two-stage compressor refrigeration, maintenance-free pressure suction pump, can carry out external closed circulation, can also carry out external open circulation, the refrigeration system adopts proportional refrigeration technology, the system energy consumption is low, and the work is stable. It is suitable for a variety of applications that require cryogenic liquids and cold traps externally.

      Features

      • Maintenance-free pressure/suction pump, resistant to fiber and metal particles, long service life, pump pressure and flow automatically adapt to external loads, effectively protect external equipment, especially glass parts.

      • The refrigeration function and the circulation function can be controlled independently or simultaneously.

      • Sealed Water Tank with intuitive level window for easy user observation of the liquid level, while the tank is equipped with a protective overflow port to prevent accidents.

      • Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

      • When the alarm is alarmed, the light and sound are reminded at the same time, and various alarm codes are directly displayed, which can directly determine the error point.

      • Pt100 temperature sensor for single- and two-point temperature calibration.

      • A variety of operating modes are available, and unexpected power failure can be automatically resumed, which can ensure the continuous supply of cooling circulating water.

      • Optional intelligent control function: a variety of interfaces (RS485, RS232), which can remotely control the start/stop of the circulating water pump and refrigeration system.

      • The input of 0-10V or 4-20mA analog signal can be selected, which can be used for the start and stop of the external intelligent device control instrument.

      • Waterproof keyboard design, high-brightness LED display.

      • Environmentally friendly refrigerant, no toxic pollution.

      • The maximum and minimum temperature settings of the machine can be defined.

      • The buzzer can be set to silent or audible.

      • The serial number of the device can be checked through the software.

      Serial models

      ModelTemperature rangeCooling capacityWater tank volume
      MiniCooler-5~RT2001
      iCooler-2003-20~RT4503
      iCooler-2006-20~RT7004.5
      iCooler-4006-40~RT8004.5
      iCooler-2009-20~RT12009
      iCooler-4009-40~RT15009
      iCooler-2017-20~RT240017
      iCooler-3017-30~RT240017
      iCooler-8005-80~RT4005
      Units: °C, W, L/min, L
      VS

      labtop icooler-4006 Low temperature chilled down liquid circulatorSpecifications

      LIST VALUE
      Temperature range -40~RT℃
      Temperature Fluctuation ±0.3±K
      Temperature display LED
      Temperature display Accuracy 0.1℃
      Temperature Control mode Smart PID
      Temperature sensor Pt100
      Cooling Capacity (20 ℃) 800W
      Pump type Pressure/suction pump
      Maximum pump pressure 0.3bar
      Maximum suction of pump 0.2bar
      Flow rate of pump 22L/min
      Pump connection interface ID=8mm
      Tank Volume 6L
      Dimensions 220*420*495mm
      Instrument fixing method desktop
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      Power supply Voltage 220V 50Hz

      labtop icooler-4006 Low temperature chilled down liquid circulator Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the difference between Icooler circulators and Miscellaneous circulators?
      [A]
      Adopting proportional refrigeration technology, which is equivalent to compressor frequency conversion function, high temperature control accuracy while saving energy and reducing consumption; pressure/suction pump Stir evenly on the liquid in the water tank, can support closed external circulation, can also support open external circulation, resistant to metal and Non-metallic impurities, maintenance-free, long life; and high temperature control accuracy, one machine multi-purpose: in addition to the cooling function chill down external equipment, LABTOP icooler products can also be used as Thermostat due to high temperature control accuracy; at the same time, the temperature range is wide, easy to configure the heater, so that the temperature range expands to one hundred degrees or even higher; compact size, saves a lot of space for the laboratory
      +labtop icooler-4006 Low temperature chilled down liquid circulator Big data
        +labtop icooler-4006 Low temperature chilled down liquid circulatorKnowledge
        +Navigation
        labtop
        LABTOP icooler- 4006 low temperature chilled down liquid circulating machine -40 ℃/4.5L
        Service
        Focus on online sales of Lab Testing Instruments