LEPTO icooler-2009 low temperature chilled down liquid circulating machine -20 ℃/9L
Temperature range -20~ RT ℃, 0.5 ± K temperature stability, liquid filling volume 9L, display accuracy 0.1 ℃, with a variety of safety alarm functions, can realize multiple interface docking.
labtopIntroduction
iCooler low-temperature coolant circulation pump, two-stage compressor refrigeration, maintenance-free pressure suction pump, can perform external closed circulation or external open circulation. The refrigeration system adopts proportional refrigeration technology, which has low energy consumption and stable operation. Suitable for various external applications that require cryogenic liquids, cold traps.
Features
Maintenance-free pressure/suction pump, resistant to fiber and metal particles, long life, pump pressure and flow automatically adapt to external loads, effectively protecting external equipment, especially glass parts from damage.
The refrigeration function and circulation function can be controlled independently or simultaneously.
Sealed Water Tank with an intuitive liquid level window, which is convenient for users to observe the liquid level. At the same time, the Water Tank is equipped with a protective overflow port to prevent accidents.
Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.
When alarming, light and sound remind at the same time, various alarm codes are directly displayed, and the error point can be directly determined.
Pt100 temperature sensor with one-point and two-point temperature calibration.
A variety of operation modes are optional, and the accidental power failure can be automatically restored to ensure the continuous supply of cooling circulating water.
Optional intelligent control function: multiple interfaces (RS485, RS232), which can remotely control the start/stop of the circulating water pump and the refrigeration system.
Optional 0-10V or 4-20mA analog signal input, which can be used for external smart devices to control the start and stop of the instrument.
Waterproof keyboard design, bright LED display.
Environmentally friendly refrigerant, non-toxic pollution.
The maximum and minimum temperature settings of the machine can be defined.
The buzzer can be set to be silent or audible.
The device serial number can be checked through software.
Models
| model | temperature range | Cooling capacity | Tank volume |
| MiniCooler | -5~RT | 200 | 1 |
| iCooler-2003 | -20~RT | 450 | 3 |
| iCooler-2006 | -20~RT | 700 | 4.5 |
| iCooler-4006 | -40~RT | 800 | 4.5 |
| iCooler-2009 | -20~RT | 1200 | 9 |
| iCooler-4009 | -40~RT | 1500 | 9 |
| iCooler-2017 | -20~RT | 2400 | 17 |
| iCooler-3017 | -30~RT | 2400 | 17 |
| iCooler-8005 | -80~RT | 400 | 5 |
| Unit: °C, W, L/min, L | |||
labtop iCooler-2009 Low temperature chilled down liquid circulating machineSpecifications
| LIST | VALUE |
|---|---|
| Instrument type | Chilled down liquid circulation device |
| Security level (according to DIN12876) | I/NFL |
| Protection Rating protection level | IP20 |
| Temperature range | -20~RT°C |
| DIN12876 temperature stability | 0.5±K |
| Temperature display | LED |
| Temperature control method | Intelligent PID control |
| Temperature transducer | Pt100 |
| External temperature transducer interface | no |
| refrigerant | R404a |
| Cooling Capacity (10 ℃) | 1200W |
| Pump type | Pressure |
| Pump adjustability | no |
| Maximum pump pressure | 1bar |
| Pump maximum flow | 22L/min |
| Pump connection interface | RC1 / 2 |
| Storage tank Volume | 9L |
| Dimensions | 300*500*620mm |
| Temperature display Accuracy | 0.1℃ |
| Light alarm | yes |
| audible alarm | yes |
| Temperature over limit alarm | yes |
| The temperature is not enough alarm | no |
| secondary protection | no |
| Low level alarm | no |
| Calibrating options | yes |
| Instrument fixing method | table |
| Allow continuous operation | 100% |
| Allowable environment temperature | 5..32℃ |
| Allowable Relative Humidity | 80% |
| RS232 interface | option |
| USB interface | option |
| Power | 200. p...230VAC/50HzV |
| Instrument noise | ≤55db |
| Technical parameter standard | DIN 12876 |
labtop iCooler-2009 Low temperature chilled down liquid circulating machine Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Cryogenic coolant Circulating Chiller Application and selection guide: key equipment for precise temperature control
- Thermostatic circulator external open bath application
- Technical characteristics and application of iCooler small cryogenic coolant Circulating Chiller


iCooler-2009
iCooler-2009+