      LABTOP UC16 chiller chilled down water circulator 1600W/13L

      LABTOP chiller UC16 Temperature range 5~ 35 ℃, using PID temperature control, cooling capacity 1600W, is an experimental chilled down water circulation machine, UC16 adopts imported compressor and ultra-quiet fan, with multiple safety protection functions.

      Brand
      SKU: NB030756
      China labtop
      Model
      VS
      Genuinegoods
      • labtop UC16 chillerOverview

      • Specifications
      • Comments
      • FAQs
      UC16
      chiller

      uChiller series chiller is a high-end model designed for high-quality needs, equipped with pressure regulation protection bypass valve, perfect protection and alarm system, can meet the application of various industries; Optional water purification configuration to ensure clean water quality; It has a variety of alarm and output interfaces, which can provide water pressure protection alarm and water flow alarm protection. The Circulating Chiller can be equipped with a low-pressure and high-flow immersion pressure suction pump, and can also be equipped with other high-head pressure pumps

      Detail Figure 1 of the Levto UC52 Chiller

      Features

      • High-performance circulating water pump. The circulating water system is designed to purify water quality multiple times to prevent impurities from entering the Circulating Chiller system, so that the service life of the pump is longer.

      • Professional PID control technology, high temperature control accuracy.

      • Pt100 temperature sensor.

      • Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

      • Multiple safety protection: temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can be reminded at the same time when alarming.

      • The refrigeration series adopts imported compressor and ultra-quiet fan, so that the noise of the whole machine is very low, especially suitable for the application of laboratory environment.

      • When the alarm is alarmed, the light and sound are reminded at the same time, and various alarm codes are directly displayed, which can directly determine the error point.

      • Waterproof keyboard design, LCD display.

      • The maximum and minimum temperature settings of the machine can be defined.

      Serial models

      ModelCooling capacityPump flowSink volume
      UC066003.57
      UC0880047
      UC10100047
      UC121200413
      UC1616004.513
      UC2222007.513
      UC3030001713
      UC3636002825
      UC5252002825
      UC7272002825
      UC027F27002830
      UC052F52002860
      UC072F72003260
      UC085F85003290
      UC145F1450033120
      UC170F1730033120
      UC220F2250066.7140
      UC290F2900066.7140
      Other parameters
      Temperature range5~35℃
      Temperature FluctuationWithout "F": ±0.1°C, with "F": ±0.1/1.0)
      Units: °C, W, L/min, L
      Without "F" is an air-cooled integrated type, with "F" is a split-cooling split type.


      VS

      labtop UC16 chillerSpecifications

      LIST VALUE
      Temperature range 5~35℃
      Temperature Fluctuation ±0.1℃
      Temperature display liquid crystal
      Temperature display Accuracy 0.1℃
      Temperature Control mode PID
      Cooling Capacity (25 ℃) 1600W
      Maximum pump pressure 4.5L/Min
      Pump connection interface RC1/2 (4-point inner teeth) interface, which can be matched with various specifications of pipelines
      Tank Volume 13.0L
      Dimensions 400*550*670mm
      Instrument fixing method floor type
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      Rated power 800W
      Power supply Voltage 200~230VAC/50Hz
      Maximum pump pressure 1.5bar

      labtop UC16 chiller Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.