      Home> Cryogenic coolant circulating pump> labtop> labtop UC052F chiller
      labtop UC052F chiller

      LABTOP UC052F chiller chilled down water circulator

      LABTOP chiller UC052F Temperature range 5~ 35 ℃, Temperature Fluctuation is +/- 0.1 ℃. UC052F chilled down water circulation machine adopts imported refrigeration compressor, with sound and light alarm function.

      Brand
      SKU: NB030763
      China labtop
      Model
      VS
      Genuinegoods
      • labtop UC052F chillerOverview

      • Specifications
      • Comments
      • FAQs
      UC052F
      chiller

      The split chiller consists of an indoor unit and an outdoor unit. The outdoor unit of this series of products is composed of a refrigeration compressor, an exhaust fan and a condenser, which exhausts all the heat generated by refrigeration to the outside, and the main noise source is also outside. The indoor unit consists of a water pump, a Water Tank and an evaporator, with no heat production and low noise. The split design concept significantly reduces the noise level of the device and improves the comfort of use. At the same time, the equipment can output more refrigeration power.

      Detail Figure 1 of the UC052F chiller

      Features

      • Environment-friendly chiller, suitable for laboratory equipment with high requirements for environmental comfort and noise.

      • The LCD screen, the actual temperature, the set temperature, and the return difference value are displayed at the same time, which is clear at a glance.

      • High-performance circulating water pump. The circulating water system is designed to purify water quality multiple times to prevent impurities from entering the Circulating Chiller system, so that the service life of the pump is longer.

      • Professional PID control technology, high temperature control accuracy.

      • Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

      • Multiple safety protection: temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can be reminded at the same time when alarming.

      • The refrigeration series adopts imported compressor and ultra-quiet fan, so that the noise of the whole machine is very low, especially suitable for the application of laboratory environment.

      • When the alarm is alarmed, the light and sound are reminded at the same time, and various alarm codes are directly displayed, which can directly determine the error point.

      • The maximum and minimum temperature settings of the machine can be defined.

      Applications

      This series of products are mainly used in X-ray diffractometer, X-ray fluorescence spectrometer, large-scale emission electron microscope, plasma etching and other large-scale laboratory equipment and vacuum coater, ion coater, vacuum furnace, industrial furnace and other industrial equipment with large calorific value, and have achieved good results.

      Serial models

      ModelTemperature rangeTemperature FluctuationCooling capacityPump flowSink volumeDimensionsremark
      [℃][℃]  [W][L/Min][L](W x D x H) [mm]
      UC065...35±0.16003.5L/Min@0.5bar7300x500x620Air-cooled all-in-one
      UC085...35±0.18004.0L/Min@1.5bar7300x500x620Air-cooled all-in-one
      UC105...35±0.110004.0L/Min@1.5bar7300x500x620Air-cooled all-in-one
      UC125...35±0.112004.0L/Min@3.5bar13400x550x670Air-cooled all-in-one
      UC165...35±0.116004.5L/Min@1.5bar13400x550x670Air-cooled all-in-one
      UC225...35±0.122007.5L/Min@4.0bar13400x550x670Air-cooled all-in-one
      UC305...35±0.1300017.0L/Min@4.0bar13400x550x670Air-cooled all-in-one
      UC365...35±0.1360028L/Min@2.4bar25530x710x960Air-cooled all-in-one
      UC525...35±0.1520028L/Min@2.4bar25530x710x960Air-cooled all-in-one
      UC725...35±0.1720028L/Min@2.4bar25530x710x960Air-cooled all-in-one
      UC027F5...35±0.1/1.0270028L/Min@2.4bar30Indoors:405x510x760;Air-cooled split type
      Outside:685x255x540
      UC052F5...35±0.1/1.0520028L/Min@2.4bar60Indoors:445x565x890;Air-cooled split type
      Outside:825x310x790
      UC072F5...35±0.1/1.0720032L/Min@3.3bar60Indoors:445x565x890;Air-cooled split type
      Outside:835x365x820
      UC085F5...35±0.1/1.0850032L/Min@3.3bar90Indoors:445x565x890;Air-cooled split type
      Outside:835x365x820
      UC145F5...35±0.1/1.01450033L/Min@4.3bar120Indoors:515x675x930;Air-cooled split type
      Outside:955x365x1210
      UC170F5...35±0.1/1.01730033L/Min@4.3bar120Indoors:515x675x930Air-cooled split type
        Outside:1300x450x1300
      UC220F5...35±0.1/1.02250066.7L/Min@4.8bar140Indoors:560X720X1010Air-cooled split type
        Outside:1550x520x1720
      UC290F5...35±0.1/1.02900066.7L/Min@4.8bar140Indoors:560X720X1010Air-cooled split type
        Outside:1550x520x1720


      VS

      labtop UC052F chillerSpecifications

      LIST VALUE
      Temperature range 5~35℃
      Temperature Fluctuation ±0.1℃
      Temperature display LCD
      Temperature display Accuracy 0.1℃
      Temperature Control mode Smart PID
      Cooling Capacity (25 ℃) 5200W
      Flow rate of pump 28L/min
      Pump connection interface RC1/2 (4-point inner teeth) interface, which can be matched with various specifications of pipelines
      Tank Volume 60L
      Dimensions Indoor: 445 * 565 * 890mm; Outdoor: 825 * 310 * 790mm
      Instrument fixing method floor type
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      Maximum pump pressure 2.4bar

      labtop UC052F chiller Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +labtop UC052F chiller Big data