      Home> Cryogenic coolant circulating pump> labtop> labtop IC145 Chill down circulating water machine
      labtop IC145 Chill down circulating water machine

      LABTOP IC145 chilled down circulating water machine

      LABTOP chill down circulating water machine IC145 adopts LCD screen, display accuracy 0.1 ℃, is a floor type chill down circulating water machine, IC145 refrigeration power 14500w, tank volume 70L.

      Brand
      SKU: NB030779
      China labtop
      Model
      VS
      Genuinegoods
      • labtop IC145 Chill down circulating water machineOverview

      • Specifications
      • Comments
      • FAQs
      IC145
      Chill down circulating water machine

      General-purpose cold circulation water machine IC series

      There are many types of general-purpose cooling circulating water machines, many specifications, and are very widely used, and small general-purpose cooling circulating water machines can also be used for supporting cooling of laboratory equipment. There are two types of chillers: air-cooled all-in-one and water-cooled. The air-cooled integrated chiller is dissipated by the fan, for the high-power chiller, the fan power is large, the heat dissipation and noise are naturally large, this large heat dissipation chiller, if placed indoors, will inevitably cause the indoor temperature to rise. The use of water-cooled all-in-one machine can solve this problem very well. The water-cooled chiller uses water instead of a fan to dissipate heat, and the product has no heat discharge and low noise indoors, which is a satisfactory environment-friendly product. In addition to the multiple protections of the product system itself, the general-purpose cooling circulating water machine also provides alarm output for the external main equipment to ensure the safety of the external equipment. At the same time, the equipment can also provide a variety of communication interfaces (RS232/RS485/USB) to realize a variety of analog (0-10V or 4-20mA) and switching input and output, and then realize the remote control of the chiller by peripherals, status query and the control of other external components by the chiller.

      Detail Figure 1 of Leputo IC145 Cooling Circulating Water Machine

      Features

      1. LCD screen, actual temperature, set temperature, and return difference value are displayed at the same time, which is clear at a glance, and the keypad is automatically locked when the operation is timed out without buttons.

      2. A variety of pressure pumps are optional, and the output pressure of the pump is adjustable, which can meet a variety of applications with different pressures and different flows.

      3. Standby anti-freezing function of water pump

      4. It can be remotely controlled to switch on and off

      5. Brand compressor, silent fan, silent pump, quiet when working, suitable for applications in quiet environment.

      6. The refrigeration system has the functions of high pressure protection and overcurrent protection to prevent the compressor from overload and effectively protect the compressor.

      7. When the alarm is applied, the light and sound are reminded at the same time, and various alarm codes are directly displayed, which can directly determine the cause of the fault and the repair method.

      8. Caster design, convenient for the machine to move

      Serial models

      ModelTemperature rangeTemperature FluctuationCooling capacityPump flowPump pressureSink volumeDimensions(W x D x H)
      [℃][℃]  [W][L/Min][bar][L][mm]
      IC0105...35±0.1/1.01000100.88330x510x595
      IC0125...35±0.1/1.012001248330x510x595
      IC0165...35±0.1/1.016002218330x510x595
      IC0225...35±0.1/1.02200282.430520x415x745
      IC0275...35±0.1/1.02700282.417440x560x820
      IC0365...35±0.1/1.03600282.425530x710x960
      IC0525...35±0.1/1.05200282.425530x710x960
      IC0725...35±0.1/1.07200333.325530x710x960
      IC0855...35±0.1/1.08500284.335555x825x1320
      IC1455...35±0.1/1.014500284.370575x1320x1350
      IC1705...35±0.1/1.017000284.390775x1650x1800
      IC2205...35±0.1/1.0220001202.6150775x1650x1800
      IC2905...35±0.1/1.0290001203.4180775x1650x1800
      IC3505...35±0.1/1.0350001203.4200775x1650x1800
      IC4505...35±0.1/1.0450001304.3250900x2100x2050
      IC6005...35±0.1/1.0600001304.3270900x2100x2050
      IC7005...35±0.1/1.0700002603.4330900x2100x2050
      IC027W5...35±0.1/1.02700282.417410x520x735
      IC052W5...35±0.1/1.05200282.425440x560x820
      IC072W5...35±0.1/1.07200333.325510x810x1000
      IC085W5...35±0.1/1.08500284.335510x810x1000
      IC145W5...35±0.1/1.014500284.370510x810x1000
      IC170W5...35±0.1/1.017000284.390600x1065x1310
      IC220W5...35±0.1/1.0220001202.6150600x1065x1310
      IC290W5...35±0.1/1.0290001203.4180720x1230x1450
      IC350W5...35±0.1/1.0350001203.4200720x1230x1450
      IC450W5...35±0.1/1.0450001304.3250850x1450x1450
      IC600W5...35±0.1/1.0600001304.32701100x1800x1650
      IC700W5...35±0.1/1.0700002603.44301100x1800x1650
      IC900W5...35±0.1/1.0900002603.46201230x2130x1750
      The W at the end of the model stands for water-cooled chiller, which can be customized with different refrigeration capacity, different Water Tank volume, different circulation capacity of non-standard products, temperature controller LCD, touch screen
      VS

      labtop IC145 Chill down circulating water machineSpecifications

      LIST VALUE
      Temperature range 5~35℃
      Temperature display liquid crystal display
      Temperature Fluctuation ±1.0℃
      cooling Capacity 14500W
      head 24m
      Flow rate of pump 28L/min
      Tank Volume 70L
      Dimensions 575*1320*1350mm
      Interface size 4-Point inner teeth, can be matched with joints and pipes of different specifications
      Instrument fixing method floor type
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      Power supply Voltage 200~230VAC/50Hz
      Temperature display Accuracy 0.1℃
      Maximum pump pressure 4.3bar
      Temperature display Accuracy 0.1℃

      labtop IC145 Chill down circulating water machine Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +labtop IC145 Chill down circulating water machine Big data
        +Navigation
        labtop
        LABTOP IC145 chilled down circulating water machine
        Service
        Focus on online sales of Lab Testing Instruments