LABTOP CC-3013E High-low temperature thermostatic circulator, volume 13L
LABTOP high-low temperature thermostatic circulator CC-3013E Temperature range -30~100 ℃, using LED display, accuracy 0.1 ℃, CC-3013E thermostatic circulator is an internal and external circulation Thermostatic Bath, sink volume is 13L.
labtop-
Shangtian Jingyi DC-8006N (0.01) Low temperature Thermostatic Bath Laboratory Ultra low temperature Thermostatic Bath -80 ℃/6L
$ 6087.00 -
QIWEI DHC-2005-A Thermostatic Bath -20 ℃/0.1 ℃
$ 691.00 -
NELE GDH-3015 Ultra high accuracy Thermostatic Bath 15L/-30 ℃
$ 2056.00 -
NELE DC-2010 Thermostatic Bath vertical 10L/-20 ℃ +/- 0.05 ℃
$ 1080.00 -
Shangtian Jingyi DHC-0506 high-low temperature thermostat, high precision high-low temperature thermostat -5~ 160 ℃/6L
$ 1178.00
CC series thermostatic circulator integrates heating and refrigeration functions, the Water Bath body is made of stainless steel, and the outside is insulated with thermal insulation cotton, which provides an economical solution for the sample to be placed directly in the Water Bath for constant temperature test, the sink volume is available in 5L and 8L two options, the model does not have "+" Optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and cycling applications, with "+" in the model Equipped with an external circulation adapter and an external temperature sensor PT100 as standard, the pump is even more powerful with pressures of up to 0.7 bar and suction forces of up to 0.4 bar. It is suitable for temperature control, material testing, quality control, analysis, etc. of samples. Use eco-friendly natural refrigeration. Level and over-temperature protection, safety class III/FL for use with flammable liquids in accordance with DIN 12876.

Features
Professional proportional refrigeration control technology, the refrigeration capacity is output proportionally at the control point, and the compressor does not need 100% output, which is more energy-saving.
CIT Just-in-Time Cooling Technology allows the compressor to be started directly to cool down even at high temperatures.
Low liquid level protection to prevent dry burning.
Optional multi-stage programmable controller, users can realize multi-stage program control, such as timing heating, cooling, constant temperature, slope and time of each section, each section of the program can set the running time, each section of the maximum time of 999 hours.
Equipped with an external temperature sensor interface, a movable external temperature probe can be selected, and with professional PID TAC control technology, Cascade cascade control technology, and temperature difference lock control technology inside and outside the bath, the temperature of the outside of the bath can be accurately controlled.
It can be circulated internally and externally, maintenance-free pressure/suction pump, resistant to fiber and metal particle matter, and can stir the bath in both horizontal and vertical directions, so that the stirring is more uniform, and the pump pressure and flow rate automatically adapt to the external load.
Maintenance-free pressure/suction pump, resistant to fiber and metal particles, can stir the bath in both horizontal and vertical directions, making the stirring more uniform, and the pump pressure and flow rate automatically adapt to the external load.
Multiple safety protection: low liquid level protection, light and sound can be reminded at the same time when the alarm can be given.
High-performance stainless steel and high-performance plastics are used for parts that come into contact with liquids or vapors.
Pt100 temperature sensor for two- and multi-point temperature calibration.
The detachable air inlet dust screen cover is very easy to maintain.
The buzzer can be set to silent or audible.
A variety of operating modes are available, and unexpected power failure can be automatically recovered.
1) Mode 1: When the power supply is disconnected during the operation of the device, the next power-on device is in the normal stop state, and the setting value can be changed.
2) Mode 2: When the power supply is disconnected during the operation of the device, the next power-on device will run automatically, and the setting value can be changed.
3) Mode 3: When the power supply is disconnected during the operation of the device, the device will run automatically the next time it is powered on, and the setting value cannot be changed.
Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control the start and stop of the equipment.
The input of 0-10V or 4-20mA analog signal can be selected, which can be used for the start and stop of the external intelligent device control instrument.
The serial number of the device can be checked through the software.
Two external contacts are optional, which can be connected to an external alarm.
An optional set of 12V switching output signals is used to control the external solenoid valve.
An optional set of 5V external input switching signals can be used for external smart devices to control the start and stop of the instrument.
The input of 0-10V or 4-20mA analog signal can be selected, which can be used for the start and stop of the external intelligent device control instrument.
CC series models
| Model | Temperature range | Heating power | Bath volume |
| CC-1008E | -10~100 | 2 | 8 |
| CC-2508E | -25~100 | 2 | 8 |
| CC-1013E | -10~100 | 2 | 13 |
| CC-2013E | -20~100 | 2 | 13 |
| CC-3013E | -30~100 | 2 | 13 |
| CC-1017E | -10~100 | 2 | 17 |
| CC-2017E | -20~100 | 2 | 17 |
| CC-0520E | -5~100 | 2 | 20 |
| CC-2020E | -20~100 | 2 | 20 |
| CC-0527E | -5~100 | 2 | 27 |
| CC-2027E | -20~100 | 2 | 27 |
| CC-1008 | -10~200 | 2 | 8 |
| CC-2508 | -25~200 | 2 | 8 |
| CC-2508P | -25~250 | 2 | 8 |
| CC-2013 | -20~220 | 2 | 13 |
| CC-3013 | -30~220 | 2 | 13 |
| CC-2017 | -20~220 | 2 | 17 |
| CC-3017 | -30~220 | 2 | 17 |
| CC-2020 | -20~220 | 3 | 20 |
| CC-2027 | -20~220 | 2 | 27 |
| Unit: °C/Kw/L | |||
labtop CC-3013E High-low temperature thermostatic circulatorSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -30~100℃ |
| Tank Volume | 13L |
| Flow rate of pump | 12L/min |
| Temperature Fluctuation | ±0.05~0.1℃ |
| Temperature Display mode | LED |
| Temperature Resolution | 0.1℃ |
| Temperature Control mode | Smart PID |
| Temperature sensor | Pt100 |
| Heating power | 2000W |
| Pump type | Pressure/suction pump |
| Pump connection interface | M16x1 |
| Tank opening Dimensions | 290*145*150mm |
| Dimensions | 350*400*660mm |
| Instrument fixing method | floor type |
| Allow continuous operation | 100% |
| Environmental temperature | 5~32℃ |
| Allowable Relative Humidity | 80% |
| Power supply Voltage | 200~230VAC/50Hz |
| Maximum pump pressure | 0.2bar |
| Maximum suction of pump | 0.1bar |
| Cooling Capacity 10 ℃ | 900w |
labtop CC-3013E High-low temperature thermostatic circulator Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CC-3013E