        iCooler-2009+ 
        External circulation thermostat circulator

        The external circulation high-low temperature constant temperature circulator products provide an economical and environmentally friendly high-low temperature constant temperature circulation solution for the laboratory. The compact design makes it quite small and very quiet to work with, and the small ones can be used directly on the table and in the fume window, and the large ones have a very small footprint. There are three types of temperature control modes for external circulation: internal control, sample control, and tracking setting control, and users can control the temperature of the tank, the temperature of external materials, and the slope according to the different temperature control methods. The program control type can also carry out 30 stages of program control, and it is very convenient for users to set the program to achieve multi-stage control such as temperature rise, constant temperature, and cooling. It is especially suitable for temperature control of glass reactors, metal reactor jackets and internal materials of reactors, as well as any application where external needs require constant temperature control.

        Detail Figure 1 of the iCooler-4009P External Circulation High and Low Temperature Thermostatic Circulator

        Features

        1. Touch screen TFT display, touch operation, small size;

        2. Proportional refrigeration and PID control technology are combined, CIT technology can directly cool down even at high temperatures.

        3. Maintenance-free pressure/suction pump, resistant to fiber and metal particle matter, long life, pump pressure and flow automatically adapt to external load, effectively protect the damage of external equipment, especially glass parts;

        4. Programmable control, 30 programs can be edited to achieve liquid temperature rise, cooling, constant temperature and other combination control (optional)

        5. Sealed Water Tank with intuitive liquid level window, which is convenient for users to observe the liquid level, and the Water Tank is equipped with a protective overflow port to prevent accidents;

        6. Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.

        7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can be reminded at the same time when alarming.

        8. When the alarm is alarmed, the light and sound are reminded at the same time, the buzzer can be set to silent or sound, and various alarm codes are directly displayed, and the error point can be directly determined

        9. Internal and external Pt100 temperature sensor, single point and two point temperature calibration, can control the temperature of external materials

        10. A variety of operation modes are optional, and the unexpected power failure can be automatically restored, which can ensure the continuous supply of cooling circulating water.

        11. Optional intelligent control function: a variety of interfaces (RS485, RS232), can remotely control the start/stop of the machine through the input of 0-10V or 4-20mA analog signal.

        12. Environmentally friendly refrigerant, no toxic pollution;

        13. The maximum temperature and minimum temperature settings of the machine can be limited

        Serial models

        ModelTemperature rangeCooling capacityheatingvolume
        iCooler-2003+-20~10045015003
        iCooler-2006+-20~10070015004.5
        iCooler-4006+-40~10080015004.5
        iCooler-2009+-20~100120015009
        iCooler-4009+-40~100150020009
        iCooler-2017+-20~1002400300017
        iCooler-2003P-20~10045015003
        iCooler-2006P-20~10070015006
        iCooler-4006P-40~10080015006
        iCooler-2009P-20~100120015009
        iCooler-4009P-40~100150020009
        Unit: °C/W/L


        VS

        labtop iCooler-2009+  External circulation thermostat circulatorSpecifications

        LIST VALUE
        Instrument type Chilled down liquid circulation device
        Protection level I/NFL
        Protection level IP20
        Temperature range -20~100℃
        Temperature fluctuation 0.05K
        Temperature display TFT
        Temperature control method Smart PID
        Temperature transducer Pt100
        Temperature transducer without
        refrigerant R404a
        Cooling Capacity 10 ℃ 1200W
        Pump type Pressure/Suction Pumps
        Pump adjustability without
        Maximum pump pressure 1bar
        Pump flow 22L/min
        Pump connection interface M16x1
        Tank Volume 9L
        Dimensions 300*500*620mm
        temperature resolution 0.01℃
        Light alarm Yes.
        audible alarm Yes.
        Temperature over limit alarm Yes.
        The temperature is not enough alarm without
        secondary protection without
        Low level protection without
        Calibrating options Yes.
        Allow continuous operation 100%
        Allowable environment temperature 5~32℃
        Allowable Relative Humidity 80%
        RS232 interface optional
        USB interface optional
        Weight 35kg
        Power 200~230VAC/50Hz
        Instrument noise ≤45pcs
        Technical parameter standard DIN 12876

        labtop iCooler-2009+  External circulation thermostat circulator Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the difference between Icooler circulators and Miscellaneous circulators?
        [A]
        Adopting proportional refrigeration technology, which is equivalent to compressor frequency conversion function, high temperature control accuracy while saving energy and reducing consumption; pressure/suction pump Stir evenly on the liquid in the water tank, can support closed external circulation, can also support open external circulation, resistant to metal and Non-metallic impurities, maintenance-free, long life; and high temperature control accuracy, one machine multi-purpose: in addition to the cooling function chill down external equipment, LABTOP icooler products can also be used as Thermostat due to high temperature control accuracy; at the same time, the temperature range is wide, easy to configure the heater, so that the temperature range expands to one hundred degrees or even higher; compact size, saves a lot of space for the laboratory
        [Q]
        Is there a GB/T26808 standard thermostatic circulator?
        [A]
        This LABTOP thermostatic circulator is fine!
        [Q]
        What is the low temperature limit of this iCoolero-2009 + high and low temperature thermostatic circulator?
        [A]
        LABTOP iCoolero-2009 + meets the Temperature range of -20 to 100 ° C, with a minimum temperature of -20 ° C.
        labtop
        LEPTO iCooler-2009 + external circulation thermostat circulator
        Service
        Focus on online sales of Lab Testing Instruments