LEPTO iCooler- 4009 + external circulation thermostat circulator
LEPTO high-low temperature thermostat circulator iCooler- 4009 + adopts external circulation pump, Temperature range -40~100 ℃, control temperature transducer PT100, iCooler- 4009 + high-low temperature thermostat circulator has sound and light alarm function, optional RS232 data interface.
labtop-
NELE GH-10 Ultra high accuracy thermostatic water and oil tank 10L/100 ℃
$ 759.00 -
BOZHEN BZ-204 Low temperature Thermostatic Water Bath -40~95 ℃/7.5L
$ 2012.00 -
HUXI HLC-2027SH Vertical High and Low Temperature Thermostat -20 ℃/27L
$ 2496.00 -
Shangtian Jingyi DHC-2006N high-low temperature thermostatic tank, refrigeration and heating circulating tank -20~160 ℃/6L
$ 1401.00 -
Shangtian Jingyi DHC-0510N high-Low Temperature Circulating Bath, precision constant temperature circulating tank -5~ 160 ℃/10L
$ 1501.00
External circulation high-low temperature constant temperature circulator products provide laboratories with economical and environmentally friendly high-low temperature constant temperature circulation solutions. The compact structure design makes the appearance quite small, and it is very quiet when working. The small one can be directly placed on the desktop and used in the ventilation window, and the large one occupies a very small area. Three temperature control methods can be selected for the external circulation temperature control method: internal control, sample control, and tracking setting control. Users can control the Water Tank temperature, external material temperature, and slope control according to different temperature control methods. The program control type can also carry out 30-segment program control, and the user can easily set the program to realize multi-segment control such as heating, constant temperature, and cooling. It is especially suitable for temperature control of glass reactors, metal reactor jackets, temperature control of materials inside reactors, and any external application that requires constant temperature control.

Features
1. Touch screen TFT display, touch operation, small size;
2. The combination of proportional refrigeration and PID control technology, CIT technology can directly cool down even at high temperature.
3. Maintenance-free pressure/suction pump, resistant to fiber and metal particles, long life, pump pressure and flow automatically adapt to external loads, effectively protecting external equipment, especially glass parts from damage;
4. Programmable control, you can edit 30 programs to realize liquid temperature heating, cooling, constant temperature and other combined control (optional)
5. The Water Tank is sealed, with an intuitive liquid level window, which is convenient for users to observe the liquid level. At the same time, the Water Tank is equipped with a protective overflow port to prevent accidents;
6. Stable and reliable system: high-performance and high-quality spare parts, stable quality and reliable performance.
7. Multiple safety protection: water shortage protection, temperature protection, water pressure protection, overheating and overcurrent protection, light and sound can remind at the same time when alarming.
8. Light and sound remind at the same time when alarming, the buzzer can be set to be silent or sound, various alarm codes are directly displayed, and the error point can be directly determined
9. Internal and external Pt100 temperature sensors, which can perform single-point and two-point temperature calibration, and can control the temperature of external materials
10. A variety of operating modes are optional, and the power can be automatically restored in case of accidental power failure, which can ensure the continuous supply of cooling circulating water.
11. Optional intelligent control function: a variety of interfaces (RS485, RS232), through the input of 0-10V or 4-20mA analog signal to realize the remote control of the start/stop of the machine.
12. Environmentally friendly refrigerant, non-toxic pollution;
13. The maximum and minimum temperature settings of the machine can be limited
Models
| model | temperature range | Cooling capacity | heating | volume |
| iCooler-2003+ | -20~100 | 450 | 1500 | 3 |
| iCooler-2006+ | -20~100 | 700 | 1500 | 4.5 |
| iCooler-4006+ | -40~100 | 800 | 1500 | 4.5 |
| iCooler-2009+ | -20~100 | 1200 | 1500 | 9 |
| iCooler-4009+ | -40~100 | 1500 | 2000 | 9 |
| iCooler-2017+ | -20~100 | 2400 | 3000 | 17 |
| iCooler-2003P | -20~100 | 450 | 1500 | 3 |
| iCooler-2006P | -20~100 | 700 | 1500 | 6 |
| iCooler-4006P | -40~100 | 800 | 1500 | 6 |
| iCooler-2009P | -20~100 | 1200 | 1500 | 9 |
| iCooler-4009P | -40~100 | 1500 | 2000 | 9 |
| Unit: ℃/W/L | ||||
labtop iCooler-4009+ External circulation thermostat circulatorSpecifications
| LIST | VALUE |
|---|---|
| Instrument type | Chilled down liquid circulation device |
| Protection level | I/NFL |
| Protection level | IP20 |
| Temperature range | -40~100℃ |
| Temperature fluctuation | 0.05K |
| Temperature display | TFT |
| Temperature control method | Smart PID |
| Temperature transducer | Pt100 |
| Temperature transducer | without |
| refrigerant | R404a |
| Cooling Capacity 10 ℃ | 1500W |
| Pump type | Pressure/Suction Pumps |
| Pump adjustability | without |
| Maximum pump pressure | 1bar |
| Pump flow | 22L/min |
| Pump connection interface | M16x1 |
| Tank Volume | 9L |
| Dimensions | 300*500*620mm |
| temperature resolution | 0.01℃ |
| Light alarm | Yes. |
| audible alarm | Yes. |
| Temperature over limit alarm | Yes. |
| The temperature is not enough alarm | without |
| secondary protection | without |
| Low level protection | without |
| Temperature range | -40~100℃ |
| Calibrating options | Yes. |
| Allow continuous operation | 100% |
| Allowable environment temperature | 5~32℃ |
| Allowable Relative Humidity | 80% |
| RS232 interface | optional |
| USB interface | optional |
| Weight | 35kg |
| Power | 200~230VAC/50Hz |
| Instrument noise | ≤45pcs |
| Technical parameter standard | DIN 12876 |
labtop iCooler-4009+ External circulation thermostat circulator Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Learn how to choose a Lepto thermostatic circulator in one article
- Thermostatic circulator external open bath application
- Technical characteristics and application of iCooler small cryogenic coolant Circulating Chiller
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 26809-2011
- ActiveGB/T 32710.3-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011


iCooler-4009+
iCooler-4009