      Home> Thermostat> labtop> labtop BC213E Bath thermostat circulator

      LEPTO BC213E Bath Thermostat Circulator

      LEPTO BC213E bath thermostat circulator operation temperature range (-20) RT + 10... 150 ℃, heating power 2000W, pump type pressure/suction pump, pump maximum pressure 0.2bar, pump maximum suction 0.1bar, pump maximum flow 12L/min

      Brand
      SKU: NB030857
      China labtop
      Model
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • labtop BC213E Bath thermostat circulatorOverview

        • Specifications
        • Comments
        • FAQs
        BC213E
        Bath thermostat circulator

        BC series thermostatic circulator is a thermostatic circulation device with heating head, with the help of cooling coil, with the help of external circulating water or coolant tank, the temperature can reach room temperature or reach -20 °C, the Water Bath body is made of stainless steel, and the outside is filled with aluminum silicate wool to keep warm, which provides an economical solution for the sample to be directly placed in the Water Bath for constant temperature test, and the optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and circulation applications. It is suitable for temperature control, material testing, quality control, analysis, etc. of samples. Use eco-friendly natural refrigeration. Level and over-temperature protection, safety class III/FL for use with flammable liquids in accordance with DIN 12876.

        Detail Figure 1 of the BC327 Bath Thermostatic Circulator

        Features

        1. Hardware over-temperature protection, the user can set the protection temperature through the knob, in the case of the failure of the equipment program, it can still be over-temperature protection to avoid dry burning, in line with the DIN12876 standard level III, flammable bath can be used.;

        2. Maintenance-free pressure/suction pump, pump pressure and flow automatically adapt to external load.

        3. Optional multi-segment programmable controller, users can realize multi-stage program control, such as timing heating, cooling, constant temperature, slope and time of each section, each section of the program can set the running time, the maximum time of each section is 999 hours

        4. Equipped with external temperature sensor interface, optional movable external temperature probe, with professional PID TAC control technology, Cascade cascade control technology, and temperature difference lock control technology inside and outside the bath, it can accurately control the temperature of the material outside the bath;

        5. Pt100 temperature sensor, which can be calibrated for single point and two-point and multi-point temperature;

        6. High-performance stainless steel and high-performance plastic parts that come into contact with liquids or vapors.

        7. Optional for different interior and exterior applications;

        8. The buzzer can be set to be silent or sound

        9. A variety of operation modes are optional, and the unexpected power failure can be automatically recovered

            Mode 1: When the power supply is disconnected during the operation of the device, the next power-on device is in the normal stop state, and the setting value can be changed.

            Mode 2: When the power supply is disconnected during the operation of the device, the next time the device is powered on, the device will run automatically, and the setting value can be changed.

            Mode 3: When the power supply is disconnected during the operation of the device, the device will run automatically the next time it is powered on, and the setting value cannot be changed.

        10. The serial number of the device can be checked through the software

        11. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control the start and stop of the equipment.

        12. Normally open and normally closed 2 external contacts are optional, and external alarms can be connected.

        13. A set of 12V switch output signals can be selected to control the external solenoid valve.

        14. A set of 5V external input switching signals can be selected, which can be used for the start and stop of external intelligent equipment control instruments.

        15. Optional 0-10V or 4-20mA analog signal input, which can be used for external intelligent equipment to control the start and stop of the instrument.

        Serial models

        ModelTemperature rangeHeating powerBath volume
        BC206ERT+10~10026
        BC206RT+10~22026
        BC208RT+10~30028
        BC210ERT+10~100210
        BC213ERT+10~100213
        BC217ERT+10~100217
        BC220ERT+10~100220
        BC320ERT+10~100320
        BC227ERT+10~100227
        BC327ERT+10~100327
        BC210RT+10~220210
        BC213RT+10~220 213
        BC217RT+10~220217
        BC220RT+10~220220
        BC320RT+10~220320
        BC227RT+10~220227
        BC327RT+10~220327
        Unit: °C/Kw/L


        VS

        labtop BC213E Bath thermostat circulatorSpecifications

        LIST VALUE
        Temperature range (-20)RT+10~150°C
        Temperature fluctuation ±0.05~0.1±K
        Temperature display LED
        temperature resolution 0.1°C
        Temperature control method Smart PID
        Temperature transducer Pt100
        Heating power 2000W
        Pump type Pressure/Suction Pumps
        Maximum pump pressure 0.2bar
        Maximum suction of pump 0.1bar
        Pump flow 12L/min
        Pump connection interface M16x1mm
        Tank Volume 13L
        Tank opening Dimensions 168*300*150mm
        Dimensions 330*360*400mm
        Instrument fixing method desktop
        Allow continuous operation 100%
        Allowable environment temperature 5~32℃
        Allowable Relative Humidity 80%
        Power 200~230VAC/50Hz

        labtop BC213E Bath thermostat circulator Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Does this bath thermostatic circulator comply with GB/T26808 standard?
        [A]
        The bath thermostatic circulator is suitable for GB/T26808, please consult customer service for detailed application definition
        [Q]
        What is the minimum temperature that can be controlled for this BC213E bath thermostatic circulator?
        [A]
        LABTOP BC213E meets the Temperature range of -20 to 150 ° C, with a minimum temperature of -20 ° C.
        labtop