LEPTO BC227E Bath Thermostat Circulator
LEPTO BC227E bath thermostat circulator operation temperature range (-20) RT + 10... 150 ℃, heating power 2000W, pump type pressure/suction pump, pump maximum pressure 0.3bar, pump maximum suction 0.2bar, pump maximum flow 22L/min
labtop-
Shangtian Jingyi DHC-2010 high-low temperature thermostat, constant temperature refrigeration thermostat -20~160 ℃/10L
$ 1551.00 -
Nile NLSC-10A super constant temperature Bath (Water/Oil), Circulating Bath (Water/Oil) 10L/200 ℃
$ 543.00 -
SANFA DKU-302 Thermostatic Oil Bath 300 ℃/ +/- 0.2 ℃
$ 756.00 -
Shangtian Jingyi DC-4020N (0.01) Low Temperature Thermostatic Bath Low Thermostatic Water Bath -40 ℃/20L
$ 3724.00 -
Shangtian Jingyi DHC-1010 high-Low Temperature Circulating Bath, hot and cold Constant Temperature Water/Oil Bath -10~160 ℃/10L
$ 1414.00
BC series constant temperature circulator is a constant temperature circulation device with heating head. With the help of cooling coil, with the help of external circulating water or cooling liquid tank, the temperature can reach room temperature or reach -20 ℃. The Water Bath tank is made of all stainless steel. The outside is filled with aluminum silicate cotton for insulation, which provides an economical solution for the sample to be placed directly in the Water Bath for constant temperature tests. The optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and circulation applications. It is suitable for temperature control of samples, material testing, quality control, analysis, etc. Operating Environmentally friendly natural refrigeration. With liquid level protection and over-temperature protection function, in line with safety class III / FL can use flammable liquid, in line with DIN 12876 standard.

Features
1. Hardware over-temperature protection. The user can set the protection temperature through the knob. In the case of equipment program failure, it can still be over-temperature protection to avoid dry burning. It meets the DIN12876 standard III level and can use flammable bath fluid. ;
2. Maintenance-free pressure/suction pump, pump pressure and flow automatically adapt to external load.
3. Optional multi-segment programmable controller, the user can realize multi-segment program control, such as timing heating, cooling, constant temperature, slope and time of each segment, each program can set the running time, and the maximum time of each segment is 999 hours
4. Equipped with an external temperature sensor interface, optional removable external temperature probe, combined with professional PID TAC control technology, Cascade cascade control technology, and internal and external temperature difference lock control technology of the bath, can accurately control the temperature of the external material of the bath;
5. Pt100 temperature sensor, capable of single-point, two-point and multi-point temperature calibration;
6. The parts in contact with liquid or steam are made of high-performance stainless steel and high-performance plastic.
7. Relevant accessories can be selected to form different internal and external applications;
8. The buzzer can be set to be silent or sound
9. A variety of operating modes are optional, and accidental power failure can be automatically restored
Mode 1: When the power is cut off during the operation of the equipment, the next time the equipment is powered on, the equipment will be in a normal stop state, and the set value can be changed.
Mode 2: When the power is cut off during the operation of the device, the device will automatically run next time it is powered on, and the set value can be changed.
Mode 3: When the power is cut off during the operation of the device, the device will automatically run next time it is powered on, and the set value cannot be changed.
10. The serial number of the device can be checked through the software
11. Optional intelligent control function: multiple interfaces (RS485, RS232), realize remote communication, and control the start and stop of equipment.
12. Optional normally open and normally closed 2 external contacts, which can be connected to an external alarm.
13. A group of 12V switch output signals can be selected for controlling external solenoid valves.
14. A group of 5V external input switch signals can be selected, which can be used for the start and stop of external smart devices to control the instrument.
15. Optional 0-10V or 4-20mA analog signal input, which can be used for external smart devices to control the start and stop of the instrument.
Models
| model | temperature range | heating power | Bath volume |
| BC206E | RT+10~100 | 2 | 6 |
| BC206 | RT+10~220 | 2 | 6 |
| BC208 | RT+10~300 | 2 | 8 |
| BC210E | RT+10~100 | 2 | 10 |
| BC213E | RT+10~100 | 2 | 13 |
| BC217E | RT+10~100 | 2 | 17 |
| BC220E | RT+10~100 | 2 | 20 |
| BC320E | RT+10~100 | 3 | 20 |
| BC227E | RT+10~100 | 2 | 27 |
| BC327E | RT+10~100 | 3 | 27 |
| BC210 | RT+10~220 | 2 | 10 |
| BC213 | RT+10~220 | 2 | 13 |
| BC217 | RT+10~220 | 2 | 17 |
| BC220 | RT+10~220 | 2 | 20 |
| BC320 | RT+10~220 | 3 | 20 |
| BC227 | RT+10~220 | 2 | 27 |
| BC327 | RT+10~220 | 3 | 27 |
| Unit: ℃/Kw/L | |||
labtop BC227E Bath thermostat circulatorSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | (-20)RT+10~150°C |
| Temperature fluctuation | ±0.05~0.1±K |
| Temperature display | LED |
| temperature resolution | 0.1°C |
| Temperature control method | Smart PID |
| Temperature transducer | Pt100 |
| Heating power | 2000W |
| Pump type | Pressure/Suction Pumps |
| Maximum pump pressure | 0.3bar |
| Maximum suction of pump | 0.2bar |
| Pump flow | 22L/min |
| Pump connection interface | M16x1mm |
| Tank Volume | 27L |
| Tank opening Dimensions | 300*340*200mm |
| Dimensions | 330*540*450mm |
| Instrument fixing method | desktop |
| Allow continuous operation | 100% |
| Allowable environment temperature | 5~32℃ |
| Allowable Relative Humidity | 80% |
| Power | 200~230VAC/50Hz |
labtop BC227E Bath thermostat circulator Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 9966.2-2020
- ActiveGB/T 28853-2012
- ActiveGB/T 32710.5-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011
- ActiveGB/T 2005-19787


BC227E