Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermostat> labtop> labtop BC220 Bath thermostatic circulator
      labtop BC220 Bath thermostatic circulator

      LABTOP BC220 bath thermostatic circulator

      Temperature range T + 10~220 ℃, display accuracy 0.01 ℃, Heating power 2000W, pump type pressure/suction pump, sink volume 20L, bath opening 300x340x150mm.

      Brand
      SKU: NB030866
      China labtop
      Model
      VS
      Genuinegoods
      • labtop BC220 Bath thermostatic circulatorOverview

      • Specifications
      • Comments
      • FAQs
      BC220
      Bath thermostatic circulator

      BC series thermostatic circulator is a thermostatic circulation device with heating head, with the help of cooling coil, with the help of external circulating water or coolant tank, the temperature can reach room temperature or reach -20 °C, the Water Bath body is made of stainless steel, and the outside is filled with aluminum silicate wool to keep warm, which provides an economical solution for the sample to be directly placed in the Water Bath for constant temperature test, and the optional external circulation adapter and external temperature sensor PT100 can be used for external temperature control and circulation applications. It is suitable for temperature control, material testing, quality control, analysis, etc. of samples. Use eco-friendly natural refrigeration. Level and over-temperature protection, safety class III/FL for use with flammable liquids in accordance with DIN 12876.

      Detail Figure 1 of the BC327 Bath Thermostatic Circulator

      Features

      1. Hardware over-temperature protection, the user can set the protection temperature through the knob, in the case of the failure of the equipment program, it can still be over-temperature protection to avoid dry burning, in line with the DIN12876 standard level III, flammable bath can be used.;

      2. Maintenance-free pressure/suction pump, pump pressure and flow automatically adapt to external load.

      3. Optional multi-segment programmable controller, users can realize multi-stage program control, such as timing heating, cooling, constant temperature, slope and time of each section, each section of the program can set the running time, the maximum time of each section is 999 hours

      4. Equipped with external temperature sensor interface, optional movable external temperature probe, with professional PID TAC control technology, Cascade cascade control technology, and temperature difference lock control technology inside and outside the bath, it can accurately control the temperature of the material outside the bath;

      5. Pt100 temperature sensor, which can be calibrated for single point and two-point and multi-point temperature;

      6. High-performance stainless steel and high-performance plastic parts that come into contact with liquids or vapors.

      7. Optional for different interior and exterior applications;

      8. The buzzer can be set to be silent or sound

      9. A variety of operation modes are optional, and the unexpected power failure can be automatically recovered

          Mode 1: When the power supply is disconnected during the operation of the device, the next power-on device is in the normal stop state, and the setting value can be changed.

          Mode 2: When the power supply is disconnected during the operation of the device, the next time the device is powered on, the device will run automatically, and the setting value can be changed.

          Mode 3: When the power supply is disconnected during the operation of the device, the device will run automatically the next time it is powered on, and the setting value cannot be changed.

      10. The serial number of the device can be checked through the software

      11. Optional intelligent control function: a variety of interfaces (RS485, RS232) to achieve remote communication, control the start and stop of the equipment.

      12. Normally open and normally closed 2 external contacts are optional, and external alarms can be connected.

      13. A set of 12V switch output signals can be selected to control the external solenoid valve.

      14. A set of 5V external input switching signals can be selected, which can be used for the start and stop of external intelligent equipment control instruments.

      15. Optional 0-10V or 4-20mA analog signal input, which can be used for external intelligent equipment to control the start and stop of the instrument.

      Serial models

      ModelTemperature rangeHeating powerBath volume
      BC206ERT+10~10026
      BC206RT+10~22026
      BC208RT+10~30028
      BC210ERT+10~100210
      BC213ERT+10~100213
      BC217ERT+10~100217
      BC220ERT+10~100220
      BC320ERT+10~100320
      BC227ERT+10~100227
      BC327ERT+10~100327
      BC210RT+10~220210
      BC213RT+10~220 213
      BC217RT+10~220217
      BC220RT+10~220220
      BC320RT+10~220320
      BC227RT+10~220227
      BC327RT+10~220327
      Unit: °C/Kw/L


      VS

      labtop BC220 Bath thermostatic circulatorSpecifications

      LIST VALUE
      Temperature range (-20)RT+10~220℃
      Temperature Fluctuation ±0.01~0.05K
      Temperature Display mode LED
      Temperature Resolution 0.01℃
      Temperature Control mode Smart PID
      Temperature sensor Pt100
      Heating power 2000W
      Pump type Pressure/suction pump
      Maximum pump pressure 0.3bar
      Maximum suction of pump 0.2bar
      Flow rate of pump 22L/min
      Pump connection interface M16x1mm
      Tank Volume 20L
      Tank opening Dimensions 300*340*150mm
      Dimensions 335*540*450mm
      Instrument fixing method desktop
      Allow continuous operation 100%
      Environmental temperature 5~32℃
      Allowable Relative Humidity 80%
      Power supply Voltage 200~230VAC/50Hz

      labtop BC220 Bath thermostatic circulator Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the low temperature limit of this BC220 bath thermostatic circulator?
      [A]
      LABTOP BC220 meets the Temperature range of -20 to 220 ° C, with a minimum temperature of -20 ° C.
      [Q]
      Does the LABTOP bath thermostatic circulator meet the GB/T26808 standard?
      [A]
      The BC220 bath thermostatic circulator can refer to
      +labtop BC220 Bath thermostatic circulator Big data
        +labtop BC220 Bath thermostatic circulatorKnowledge
        +labtop BC220 Bath thermostatic circulatorStandard
        +Navigation
        labtop
        LABTOP BC220 bath thermostatic circulator
        Service
        Focus on online sales of Lab Testing Instruments