HTechMT CO600FCS + F2R Coating Thickness Gauge Iron base, standard type, split 5000 μm
S-type iron-based host + 5mm right-angle probe, save 100,000 data
HTechMT-
LEEB261 high-precision Coating Thickness Gauge eddy Current
Login -
Defelsko PosiTector 200 B3 Wood, plastic polymer Coating Thickness Gauge Premium
$ 3264.00 -
TQC SP1111 Destructiveness Thickness Gauge Blade 1 Blade 20~2000μm Range
$ 271.00 -
Germany Nix QNix 4500 + FN1.2 integrated dual-use coating platings Thickness Gauge FeNFe dual-use probe 0-1200μm
$ 863.00 -
Defelsko PosiTector 6000 FNS3 Coating Thickness Gauge metal substrate Automatic substrate type identification and measurement
$ 1882.00
Coating Thickness Gauges provide fast and accurate measurement of non-magnetic coatings or coatings (e.g., e.g., steel, iron) on magnetic metal substrates (e.g., steel, iron).Aluminum, chromium, copper, enamel, rubber, paint, etc.) and non-magnetic metal substrates (e.g. copper, aluminum, zinc, tin, etc.)The thickness of the non-conductive cladding (e.g., enamel, rubber, paint, plastic, etc.).
Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
CO600 series classification
CO600 F A E 1
1 Range type: 1/2/3/4/5 for 1.6, 5.0, 14.0, 25.0 and 0.5 mm (integral and integral strip type)
E: Function Type: Economy (E), Basic (B), Statistical (S), Advanced (T)
A: Main unit and probe connection type: Integral type (A), integral strip type (B) and split type (C)
F: Substrate type: Iron-based (F), Non-ferrous (N)

Split
| B (Basic) | S (Standard) | T (Advanced) | |
| Iron | CO600FCB | CO600FCS | CO600FCT |
| Non-iron-based | CO600NCB | CO600NCS | CO600NCT |
Monolithic
| Range | E (Economy) | B (Basic) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAE5 | CO600FBE5 | CO600FAB5 | CO600FBB5 |
| Iron-based 1.6mm | CO600FAE1 | CO600FBE1 | CO600FAB1 | CO600FBB1 |
| Iron-based 5.0mm | CO600FAE2 | CO600FBE2 | CO600FAB2 | CO600FBB2 |
| Iron base 13.0mm | CO600FBB3 | |||
| Non-ferrous base 0.5mm | CO600NAE5 | CO600NBE5 | CO600NAB5 | CO600NBB5 |
| Non-ferrous base 1.6mm | CO600NAE1 | CO600NBE1 | CO600NAB1 | CO600NBB1 |
| Non-ferrous base 5.0mm | CO600NAE2 | CO600NBE2 | CO600NAB2 | CO600NBB2 |
| Non-ferrous base 13.0mm | CO600NAE3 | CO600NBE3 | CO600NAB3 | CO600NBB3 |
| Range | S (Standard) | T (Advanced) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAS5 | CO600FBS5 | CO600FAT5 | CO600FBT5 |
| Iron-based 1.6mm | CO600FAS1 | CO600FBS1 | CO600FAT1 | CO600FBT1 |
| Iron-based 5.0mm | CO600FAS2 | CO600FBS2 | CO600FAT2 | CO600FBT2 |
| Iron base 13.0mm | CO600FBS3 | CO600FBT3 | ||
| Non-ferrous base 0.5mm | CO600NAS5 | CO600NBS5 | CO600NAT5 | CO600NBT5 |
| Non-ferrous base 1.6mm | CO600NAS1 | CO600NBS1 | CO600NAT1 | CO600NBT1 |
| Non-ferrous base 5.0mm | CO600NAS2 | CO600NBS2 | CO600NAT2 | CO600NBT2 |
| Non-ferrous base 13.0mm | CO600NBT3 | |||
Series differences
| CO600 | E | B | S | T | |
| Coating Thickness Gauge | Economical | Basic | Standard | Advanced | |
| Overview | Dimensions | 70*150*32mm | |||
| Weight (with battery) | 200g | ||||
| display screen | 2.2 TFT | ||||
| battery | 2 x No. 5 batteries (rechargeable batteries available) | ||||
| Battery life1 | 20 hours | ||||
| Operating temperature | -10~50oC | ||||
| precision2 | ±(1-3)% | ||||
| Test speed | 60 times/min | ||||
| Feature settings | Low battery alarm | √ | √ | √ | √ |
| Smooth two-point calibration | √ | √ | √ | √ | |
| Rough two-point calibration1 | √ | √ | √ | ||
| Rough two-point calibration2 | √ | √ | √ | ||
| Zero-point calibration | √ | √ | √ | ||
| Factory calibrated | √ | √ | √ | √ | |
| language3 | √ | √ | √ | √ | |
| Ambient light sensors | √ | √ | √ | √ | |
| Automatic screen transversion | √ | √ | √ | ||
| Test tone adjustments | √ | √ | √ | ||
| Display brightness adjustment | √ | √ | √ | ||
| Upper and lower limit functions | √ | √ | √ | ||
| Screen settings | Screen statistics function | √ | √ | √ | |
| Number of measurements | √ | √ | √ | ||
| maximum | √ | √ | √ | ||
| minimum | √ | √ | √ | ||
| average value | √ | √ | √ | ||
| standard deviation | √ | √ | √ | ||
| Array statistics | Create a new group | √ | √ | ||
| Open the group | √ | √ | |||
| View the group | √ | √ | |||
| Purge groups | √ | √ | |||
| Delete the group | √ | √ | |||
| Leave the group | √ | √ | |||
| Number of groups | 10 groups | 100 groups | |||
| Total storage | 100,000 pieces | 1,000,000 | |||
| other | USB connection to PC | √ | √ | √ | √ |
| Data is downloaded to a PC | √ | √ | |||
| Firmware upgrades | √ | √ | √ | √ | |
| Wifi | √ | √ | |||
1 Different batteries or settings may vary;
2 Accuracy depends on the accuracy of the standard and the user's proficiency;
3 The language is updated without notice, please contact customer service.
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600FCS+F2R Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±1~3%/±20μm |
| Probe material | ruby |
| Calibrated mode | Smooth two-point calibrated, rough two-point calibrated, zero-point calibrated, factory calibrated |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface | USB |
| Power | 2 AA batteries (rechargeable batteries can be used) |
| Standards | ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400 |
| Language | Chinese, English, German |
| Display screen | 2.2 TFT LCD |
| Operating temperature | -10~50℃ |
| Battery life | 20h |
| Protection level | IP64 |
| Print function | No |
| Machine Weight | 200g |
| Machine size | 70*150*32mm |
| Minimum headroom | 30mm |
| Minimum measurement surface | R5mm |
| Minimum substrate thickness | 0.8mm |
| Test speed | 60 times/minute |
| Probe size | Φ9mm |
| statistical function | Create a new group, open a group, view a group, clear a group, delete a group, and exit a group |
| number of statistical groups | 10 groups |
| Data storage | Article 100,000 |
| Other functions | Data download to PC, WiFi |
HTechMT CO600FCS+F2R Coating Thickness Gauge Packing list
host X1, AA battery X2, probe X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 42541-2023
- ActiveGB/T 13912-2020
- ActiveGB/T 7991.5-2014
- ActiveGB/T 13448-2019
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012
- ActiveGB 12441-2018
- ActiveGB 14907-2018
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveGB/T 14907-2018
- AbolishGB 14907-2002
- ActiveSY/T 0315-2013
- ActiveGB 28374-2012


CO600FCS+F2R









