Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> KODIN> KODIN MC3000A
      KODIN MC3000A

      Coating Thickness Gauge MC3000A/C/D

      Coating Thickness Gauge, model MC3000A/MC3000C/MC3000D, is a split Coating Thickness Gauge, MC3000A/C/D Coating Thickness Gauge adopts the principle of magnetic thickness measurement.

      Brand
      SKU: NB003104
      China KODIN
      Model
      VS
      Information
      Genuinegoods
      • KODIN MC3000A Overview

      • Specifications
      • Comments
      • FAQs
      MC3000A

      Introduction to MC3000A/C/D Coating Thickness Gauges

      MC-3000 series coating Thickness Gauge can easily and non-destructively measure the thickness of non-magnetic coatings on ferromagnetic materials, such as zinc, copper, chromium or paint, enamel, fiberglass, rubber, spraying, asphalt and other coatings on the surface of steel.

      Key features

      ● Basic measurement mode: normal mode, minimum mode, statistical mode

      ● Monitoring and measurement mode: the difference can be set, and the upper and lower limit alarms can be set

      ● You can delete and store a single data, a group of data, or all data

      ● Zero-point calibration, two-point calibration and system calibration can be performed

      ● The shutdown mode can be set, the backlight can be turned on or off, and the factory state can be restored

      ● You can print stored values and statistical values

      ● A total of 6 groups of data are stored in groups, and each group stores 100 measurement points

      ●Stored measurements can be viewed in groups

      skillParameters

      1. Measuring range: MC-3000A 0-1200um

                                 MC-3000C   0-5000um

                                 MC-3000D   10-9000um

      2. Display accuracy: 0.1um   

      3. UnderVoltage display: "" is displayed in the upper left corner 

      4. Display mode: 3-digit LCD digital display   

      5. Storage method: Manual storage measurement   

      6. Measurement error: Measurement error (H is the thickness of the layer to be measured):

      A: ±[(1~3)%H+1um]  

      C:±[(2~3)%H+1um]  

      D: ±(3%H+1um)

      Repeatability:

      A:±(0.5%H+1um)

      C:±(1%H+1um) 

      D:±(1%H+2um)

      Display accuracy: 0~99u: 0.1 um; 100~999um: 1um; 1mm~9mm: 0.01mm 

      7. Stored value: 6 groups of 100 measuring points per group   

      8. Statistical function: average, maximum, minimum   

      9. Environment: Temperature: 0°C ~ 40°C Relative Humidity less than 90%   

      10. Power supply: 2 No. 5 batteries, continuous use time up to 200 hours    

      11. Automatic shutdown: The shutdown mode can be set manually   

      12. Key disk: 6 keys waterproof, oil-proof keyboard   

      13. SIZE/WEIGHT: 146*81*30MM 360 GRAMS   

      14. Optional : printer and communication printing line, microcomputer communication software, internal anti-corrosion probe   

      15. Standard configuration: main unit, probe, standard sample, manual, warranty card, certificate, No. 5 battery, suitcase

      VS

      KODIN MC3000A Specifications

      LIST VALUE
      Measurement principle Magnetic Induction
      Measurement range 0~1200μm
      margin of error ±3%
      probe Line probe
      statistical function MAX Maximum, MIN Minimum, Average
      Power Supply 2 * AA battery, continuous use time up to 200 hours
      Data storage 100 Measured values, 6 groups
      Machine Weight 360g
      Machine size 146*81*30mm
      Voltage prompt Display icon in upper left corner
      Display screen 3-Digit LCD digital display
      Storage method Manually stored measurements
      margin of error ±3%
      Repeatability (0.5%H+1um)
      Resolution 0.1μm
      Operating temperature 0~40℃
      Relative Humidity <90%RH
      shutdown mode The shutdown mode can be manually set.
      Keypad 6-Key waterproof, oil-proof keyboard

      KODIN MC3000A Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      KODIN
      Coating Thickness Gauge MC3000A/C/D
      Service
      Focus on online sales of Lab Testing Instruments