HTechMT CO600FBE2 platings Thickness Gauge, iron-based, economical 5000 μm
Type E Iron-based monolithic strip, 5.0mm, calibrated and measurement
HTechMT-
German EPK MiniTest 735 F1.5 statistical coating Thickness Gauge, thickness measurement 0~1500μm
$ 2247.00 -
Germany EPK FN1.6/90 Thickness Gauge probe 90 ° thickness measurement range 0~1600um
$ 2623.00 -
IWAVE WH92 split coating Film thickness meter
$ 189.00 -
Defelsko PosiTector 6000 N90S3 Coating Thickness Gauge 90 ° probe eddy Current thickness measurement principle
$ 1756.00 -
DONGRU DR130 Coating Thickness Gauge
$ 183.00
Coating Thickness Gauges provide fast and accurate measurement of non-magnetic coatings or coatings (e.g., e.g., steel, iron) on magnetic metal substrates (e.g., steel, iron).Aluminum, chromium, copper, enamel, rubber, paint, etc.) and non-magnetic metal substrates (e.g. copper, aluminum, zinc, tin, etc.)The thickness of the non-conductive cladding (e.g., enamel, rubber, paint, plastic, etc.).
Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
CO600 series classification
CO600 F A E 1
1 Range type: 1/2/3/4/5 for 1.6, 5.0, 14.0, 25.0 and 0.5 mm (integral and integral strip type)
E: Function Type: Economy (E), Basic (B), Statistical (S), Advanced (T)
A: Main unit and probe connection type: Integral type (A), integral strip type (B) and split type (C)
F: Substrate type: Iron-based (F), Non-ferrous (N)

Split
| B (Basic) | S (Standard) | T (Advanced) | |
| Iron | CO600FCB | CO600FCS | CO600FCT |
| Non-iron-based | CO600NCB | CO600NCS | CO600NCT |
Monolithic
| Range | E (Economy) | B (Basic) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAE5 | CO600FBE5 | CO600FAB5 | CO600FBB5 |
| Iron-based 1.6mm | CO600FAE1 | CO600FBE1 | CO600FAB1 | CO600FBB1 |
| Iron-based 5.0mm | CO600FAE2 | CO600FBE2 | CO600FAB2 | CO600FBB2 |
| Iron base 13.0mm | CO600FBB3 | |||
| Non-ferrous base 0.5mm | CO600NAE5 | CO600NBE5 | CO600NAB5 | CO600NBB5 |
| Non-ferrous base 1.6mm | CO600NAE1 | CO600NBE1 | CO600NAB1 | CO600NBB1 |
| Non-ferrous base 5.0mm | CO600NAE2 | CO600NBE2 | CO600NAB2 | CO600NBB2 |
| Non-ferrous base 13.0mm | CO600NAE3 | CO600NBE3 | CO600NAB3 | CO600NBB3 |
| Range | S (Standard) | T (Advanced) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAS5 | CO600FBS5 | CO600FAT5 | CO600FBT5 |
| Iron-based 1.6mm | CO600FAS1 | CO600FBS1 | CO600FAT1 | CO600FBT1 |
| Iron-based 5.0mm | CO600FAS2 | CO600FBS2 | CO600FAT2 | CO600FBT2 |
| Iron base 13.0mm | CO600FBS3 | CO600FBT3 | ||
| Non-ferrous base 0.5mm | CO600NAS5 | CO600NBS5 | CO600NAT5 | CO600NBT5 |
| Non-ferrous base 1.6mm | CO600NAS1 | CO600NBS1 | CO600NAT1 | CO600NBT1 |
| Non-ferrous base 5.0mm | CO600NAS2 | CO600NBS2 | CO600NAT2 | CO600NBT2 |
| Non-ferrous base 13.0mm | CO600NBT3 | |||
Series differences
| CO600 | E | B | S | T | |
| Coating Thickness Gauge | Economical | Basic | Standard | Advanced | |
| Overview | Dimensions | 70*150*32mm | |||
| Weight (with battery) | 200g | ||||
| display screen | 2.2 TFT | ||||
| battery | 2 x No. 5 batteries (rechargeable batteries available) | ||||
| Battery life1 | 20 hours | ||||
| Operating temperature | -10~50oC | ||||
| precision2 | ±(1-3)% | ||||
| Test speed | 60 times/min | ||||
| Feature settings | Low battery alarm | √ | √ | √ | √ |
| Smooth two-point calibration | √ | √ | √ | √ | |
| Rough two-point calibration1 | √ | √ | √ | ||
| Rough two-point calibration2 | √ | √ | √ | ||
| Zero-point calibration | √ | √ | √ | ||
| Factory calibrated | √ | √ | √ | √ | |
| language3 | √ | √ | √ | √ | |
| Ambient light sensors | √ | √ | √ | √ | |
| Automatic screen transversion | √ | √ | √ | ||
| Test tone adjustments | √ | √ | √ | ||
| Display brightness adjustment | √ | √ | √ | ||
| Upper and lower limit functions | √ | √ | √ | ||
| Screen settings | Screen statistics function | √ | √ | √ | |
| Number of measurements | √ | √ | √ | ||
| maximum | √ | √ | √ | ||
| minimum | √ | √ | √ | ||
| average value | √ | √ | √ | ||
| standard deviation | √ | √ | √ | ||
| Array statistics | Create a new group | √ | √ | ||
| Open the group | √ | √ | |||
| View the group | √ | √ | |||
| Purge groups | √ | √ | |||
| Delete the group | √ | √ | |||
| Leave the group | √ | √ | |||
| Number of groups | 10 groups | 100 groups | |||
| Total storage | 100,000 pieces | 1,000,000 | |||
| other | USB connection to PC | √ | √ | √ | √ |
| Data is downloaded to a PC | √ | √ | |||
| Firmware upgrades | √ | √ | √ | √ | |
| Wifi | √ | √ | |||
1 Different batteries or settings may vary;
2 Accuracy depends on the accuracy of the standard and the user's proficiency;
3 The language is updated without notice, please contact customer service.
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600FBE2 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±1~3%/±20μm |
| Probe material | ruby |
| Calibrated mode | Smooth two point calibrated, factory calibrated |
| Interface | USB |
| Power | 2 AA batteries (rechargeable batteries can be used) |
| Standards | ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400 |
| Language | Chinese, English, German |
| Display screen | 2.2 TFT LCD |
| Operating temperature | -10~50℃ |
| Battery life | 20h |
| Protection level | IP64 |
| Print function | No |
| Machine Weight | 200g |
| Machine size | 70*150*32mm |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Minimum substrate thickness | 0.8mm |
| Test speed | 60 times/minute |
HTechMT CO600FBE2 Coating Thickness Gauge Packing list
host X1, AA battery X2, test piece set X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 42541-2023
- ActiveGB/T 13912-2020
- ActiveGB/T 7991.5-2014
- ActiveGB/T 13448-2019
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012
- ActiveGB 12441-2018
- ActiveGB 14907-2018
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 3369-2003
- ActiveGB/T 14907-2018
- AbolishGB 14907-2002
- ActiveSY/T 0315-2013


CO600FBE2