HTechMT CO600FAS2 Cladding Thickness Gauge, Iron-based, Standard 5.0mm
S-type iron-based integral, 5.0mm, 100,000 data stored
HTechMT-
LANDTEK CM-1210-200F Coating Thickness Gauge
$ 568.00 -
AMITTARI AC-112-200F Coating Thickness Gauge Iron-based film thickness Measurement Instrument
$ 610.00 -
DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
$ 571.00 -
Defelsko NS conventional strip line probe measurement non-ferrous metal substrate coatings
$ 770.00 -
Defelsko PosiTector 6000 FNS3 Coating Thickness Gauge metal substrate Automatic substrate type identification and measurement
$ 1882.00
The coating Thickness Gauge can quickly and accurately measure the thickness of non-magnetic coatings or coatings (such as aluminum , chromium, copper, enamel, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron) and non-magnetic metal substrates (such as The thickness of non-conductive coatings (such as enamel , rubber, paint, plastics, etc.) on copper, aluminum, zinc, tin, etc.).
Implementation standards: ISO 2178/2360/2808, ISO 19840, ASTM B244/B499/D1186/D1400
CO600 series classification
CO600 FA E 1
1 Range type: 1/2/3/4/5 corresponds to 1.6, 5.0, 14.0, 25.0 and 0.5mm (whole and whole with line type)
E: Function type: Economic type (E), basic type (B), statistical type (S), advanced type (T)
A: Host and probe connection types: integral type (A), integral with line type (B) and split type (C)
F: Substrate type: Iron-based (F), non-ferrous-based (N)

split type
| B (basic type) | S (standard type) | T (advanced type) | |
| iron base | CO600FCB | CO600FCS | CO600FCT |
| Non-ferrous | CO600NCB | CO600NCS | CO600NCT |
Integral
| Measuring range | E (Economy type) | B (basic type) | ||
| Integral | Overall wired | Integral | Overall wired | |
| Iron base 0.5mm | CO600FAE5 | CO600FBE5 | CO600FAB5 | CO600FBB5 |
| Iron base 1.6mm | CO600FAE1 | CO600FBE1 | CO600FAB1 | CO600FBB1 |
| Iron base 5.0mm | CO600FAE2 | CO600FBE2 | CO600FAB2 | CO600FBB2 |
| Iron base 13.0mm | CO600FBB3 | |||
| Non-ferrous base 0.5mm | CO600NAE5 | CO600NBE5 | CO600NAB5 | CO600NBB5 |
| Non-ferrous base 1.6mm | CO600NAE1 | CO600NBE1 | CO600NAB1 | CO600NBB1 |
| Non-ferrous base 5.0mm | CO600NAE2 | CO600NBE2 | CO600NAB2 | CO600NBB2 |
| Non-ferrous base 13.0mm | CO600NAE3 | CO600NBE3 | CO600NAB3 | CO600NBB3 |
| Measuring range | S (standard type) | T (advanced type) | ||
| Integral | Overall wired | Integral | Overall wired | |
| Iron base 0.5mm | CO600FAS5 | CO600FBS5 | CO600FAT5 | CO600FBT5 |
| Iron base 1.6mm | CO600FAS1 | CO600FBS1 | CO600FAT1 | CO600FBT1 |
| Iron base 5.0mm | CO600FAS2 | CO600FBS2 | CO600FAT2 | CO600FBT2 |
| Iron base 13.0mm | CO600FBS3 | CO600FBT3 | ||
| Non-ferrous base 0.5mm | CO600NAS5 | CO600NBS5 | CO600NAT5 | CO600NBT5 |
| Non-ferrous base 1.6mm | CO600NAS1 | CO600NBS1 | CO600NAT1 | CO600NBT1 |
| Non-ferrous base 5.0mm | CO600NAS2 | CO600NBS2 | CO600NAT2 | CO600NBT2 |
| Non-ferrous base 13.0mm | CO600NBT3 | |||
Series differences
| CO600 | E | B | S | T | |
| Coating Thickness Gauge | Economical | Basic type | Standard type | Advanced type | |
| Overview | Dimensions | 70*150*32mm | |||
| Weight (including battery) | 200g | ||||
| Display | 2.2 TFT | ||||
| Battery | 2 AA batteries (rechargeable batteries available) | ||||
| Battery life1 | 20 hours | ||||
| operating temperature | -10~50 o C | ||||
| Accuracy 2 | ±(1-3)% | ||||
| Test speed | 60 times/minute | ||||
| Function settings | Low battery alarm | â | â | â | â |
| Smooth two-point calibration | â | â | â | â | |
| Rough two-point calibration 1 | â | â | â | ||
| Rough two-point calibration 2 | â | â | â | ||
| Zero point calibration | â | â | â | ||
| Factory calibration | â | â | â | â | |
| Language 3 | â | â | â | â | |
| ambient light sensor | â | â | â | â | |
| Automatically rotate screen | â | â | â | ||
| Test tone adjustment | â | â | â | ||
| Display brightness adjustment | â | â | â | ||
| Upper and lower limit functions | â | â | â | ||
| Screen settings | Screen statistics function | â | â | â | |
| Number of measurements | â | â | â | ||
| maximum value | â | â | â | ||
| minimum value | â | â | â | ||
| average value | â | â | â | ||
| standard deviation | â | â | â | ||
| Array statistics | New group | â | â | ||
| open group | â | â | |||
| View group | â | â | |||
| clear group | â | â | |||
| Delete group | â | â | |||
| Exit group | â | â | |||
| Number of groups | 10 sets | 100 groups | |||
| Total storage | 100,000 | 1 million | |||
| other | USB connection to PC | â | â | â | â |
| Data download to PC | â | â | |||
| Firmware upgrade | â | â | â | â | |
| Wifi | â | â | |||
1 There are differences between different batteries or settings;
2 The accuracy depends on the accuracy of the standard film and the user's proficiency;
3 Language types will be updated without further notice, please contact customer service.
Probe selection
| shape | Probe model | A | B | C | Measuring range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ±1-3% or 2.5 μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ±1-3% or 20 μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ±1-3% or 2.0 μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ±1-3% or 2.5 μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ±1-3% or 20 μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ±1-3% or 2.5 μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ±1-3% or 20 μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ±1-3% or 2.0 μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ±1-3% or 2.5 μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ±1-3% or 20 μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ±1-3% or 2.5 μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ±1-3% or 20 μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ±1-3% or 50 μm | 80mm | 10mm | 1.0mm |
| CO600F4S | twenty four | 60 | 50 | 26.0mm | ±1-3% or 100 μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250℃
HTechMT CO600FAS2 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±1~3%/±20μm |
| Probe material | ruby |
| Calibrated mode | Smooth two-point calibrated, rough two-point calibrated, zero-point calibrated, factory calibrated |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface | USB |
| Power Supply | 2 AA batteries (rechargeable batteries can be used) |
| Standards | ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400 |
| Language | Chinese, English, German |
| Display screen | 2.2 TFT LCD screen |
| Operating temperature | -10~50℃ |
| Battery life | 20h |
| Protection level | IP64 |
| Print function | No |
| Machine Weight | 200g |
| Machine size | 70*150*32mm |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Minimum substrate thickness | 0.8mm |
| Test speed | 60 times/minute |
| Probe size | Φ9mm |
| statistical function | Create a new group, open a group, view a group, clear a group, delete a group, and exit a group |
| number of statistical groups | 10 groups |
| Data storage | Article 100,000 |
| Other functions | Data download to PC, WiFi |
HTechMT CO600FAS2 Coating Thickness Gauge Packing list
host X1, AA battery X2, test piece set X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle, Characteristics and Application of FISCHER Coating Thickness Gauge
- Basic Principle, Characteristics and Application of Rubber Coating Thickness Gauge
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 42541-2023
- ActiveGB/T 13912-2020
- ActiveGB/T 7991.5-2014
- ActiveGB/T 13448-2019
- ActiveISO 4526-2004
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 3369-2003
- ActiveSY/T 0315-2013
- ActiveGB/T 4956-2003
- AbolishGB/T 13448-2006
- ISO 6158-1984
- ActiveISO 1461-2022
- AbolishGB/T 4956-1985
- ActiveQB/T 2183-1995
- ActiveJB/T 7217-2008


CO600FAS2