HTechMT CO600FAT1W Film Thickness Gauge iron base, advanced 1600μm
T-type iron-based integral type, 1.6mm, 1 million data stored, WIFI transmission
HTechMT-
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
$ 246.00 -
Linshang LS201 Digital Glass Film thickness meter
$ 643.00 -
Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
$ 506.00 -
Defelsko PosiTector 6000 N90S3 Coating Thickness Gauge 90 ° probe eddy Current thickness measurement principle
$ 1756.00 -
LEEB LBTQ20-3 Cladding Thickness Gauge (Multifunctional) + F1/90 ° Probe
$ 848.00
Coating Thickness Gauges provide fast and accurate measurement of non-magnetic coatings or coatings (e.g., e.g., steel, iron) on magnetic metal substrates (e.g., steel, iron).Aluminum, chromium, copper, enamel, rubber, paint, etc.) and non-magnetic metal substrates (e.g. copper, aluminum, zinc, tin, etc.)The thickness of the non-conductive cladding (e.g., enamel, rubber, paint, plastic, etc.).
Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
CO600 series classification
CO600 F A E 1
1 Range type: 1/2/3/4/5 for 1.6, 5.0, 14.0, 25.0 and 0.5 mm (integral and integral strip type)
E: Function Type: Economy (E), Basic (B), Statistical (S), Advanced (T)
A: Main unit and probe connection type: Integral type (A), integral strip type (B) and split type (C)
F: Substrate type: Iron-based (F), Non-ferrous (N)

Split
| B (Basic) | S (Standard) | T (Advanced) | |
| Iron | CO600FCB | CO600FCS | CO600FCT |
| Non-iron-based | CO600NCB | CO600NCS | CO600NCT |
Monolithic
| Range | E (Economy) | B (Basic) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAE5 | CO600FBE5 | CO600FAB5 | CO600FBB5 |
| Iron-based 1.6mm | CO600FAE1 | CO600FBE1 | CO600FAB1 | CO600FBB1 |
| Iron-based 5.0mm | CO600FAE2 | CO600FBE2 | CO600FAB2 | CO600FBB2 |
| Iron base 13.0mm | CO600FBB3 | |||
| Non-ferrous base 0.5mm | CO600NAE5 | CO600NBE5 | CO600NAB5 | CO600NBB5 |
| Non-ferrous base 1.6mm | CO600NAE1 | CO600NBE1 | CO600NAB1 | CO600NBB1 |
| Non-ferrous base 5.0mm | CO600NAE2 | CO600NBE2 | CO600NAB2 | CO600NBB2 |
| Non-ferrous base 13.0mm | CO600NAE3 | CO600NBE3 | CO600NAB3 | CO600NBB3 |
| Range | S (Standard) | T (Advanced) | ||
| Monolithic | Integral belt line type | Monolithic | Integral belt line type | |
| Iron-based 0.5mm | CO600FAS5 | CO600FBS5 | CO600FAT5 | CO600FBT5 |
| Iron-based 1.6mm | CO600FAS1 | CO600FBS1 | CO600FAT1 | CO600FBT1 |
| Iron-based 5.0mm | CO600FAS2 | CO600FBS2 | CO600FAT2 | CO600FBT2 |
| Iron base 13.0mm | CO600FBS3 | CO600FBT3 | ||
| Non-ferrous base 0.5mm | CO600NAS5 | CO600NBS5 | CO600NAT5 | CO600NBT5 |
| Non-ferrous base 1.6mm | CO600NAS1 | CO600NBS1 | CO600NAT1 | CO600NBT1 |
| Non-ferrous base 5.0mm | CO600NAS2 | CO600NBS2 | CO600NAT2 | CO600NBT2 |
| Non-ferrous base 13.0mm | CO600NBT3 | |||
Series differences
| CO600 | E | B | S | T | |
| Coating Thickness Gauge | Economical | Basic | Standard | Advanced | |
| Overview | Dimensions | 70*150*32mm | |||
| Weight (with battery) | 200g | ||||
| display screen | 2.2 TFT | ||||
| battery | 2 x No. 5 batteries (rechargeable batteries available) | ||||
| Battery life1 | 20 hours | ||||
| Operating temperature | -10~50oC | ||||
| precision2 | ±(1-3)% | ||||
| Test speed | 60 times/min | ||||
| Feature settings | Low battery alarm | √ | √ | √ | √ |
| Smooth two-point calibration | √ | √ | √ | √ | |
| Rough two-point calibration1 | √ | √ | √ | ||
| Rough two-point calibration2 | √ | √ | √ | ||
| Zero-point calibration | √ | √ | √ | ||
| Factory calibrated | √ | √ | √ | √ | |
| language3 | √ | √ | √ | √ | |
| Ambient light sensors | √ | √ | √ | √ | |
| Automatic screen transversion | √ | √ | √ | ||
| Test tone adjustments | √ | √ | √ | ||
| Display brightness adjustment | √ | √ | √ | ||
| Upper and lower limit functions | √ | √ | √ | ||
| Screen settings | Screen statistics function | √ | √ | √ | |
| Number of measurements | √ | √ | √ | ||
| maximum | √ | √ | √ | ||
| minimum | √ | √ | √ | ||
| average value | √ | √ | √ | ||
| standard deviation | √ | √ | √ | ||
| Array statistics | Create a new group | √ | √ | ||
| Open the group | √ | √ | |||
| View the group | √ | √ | |||
| Purge groups | √ | √ | |||
| Delete the group | √ | √ | |||
| Leave the group | √ | √ | |||
| Number of groups | 10 groups | 100 groups | |||
| Total storage | 100,000 pieces | 1,000,000 | |||
| other | USB connection to PC | √ | √ | √ | √ |
| Data is downloaded to a PC | √ | √ | |||
| Firmware upgrades | √ | √ | √ | √ | |
| Wifi | √ | √ | |||
1 Different batteries or settings may vary;
2 Accuracy depends on the accuracy of the standard and the user's proficiency;
3 The language is updated without notice, please contact customer service.
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600FAT1W Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~1600μm |
| margin of error | ±1~3%/2.5μm |
| Probe material | ruby |
| Calibrated mode | Smooth two-point calibrated, rough two-point calibrated, zero-point calibrated, factory calibrated |
| statistical function | Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation |
| Interface | USB |
| Power Supply | 2 AA batteries (rechargeable batteries can be used) |
| Standards | ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400 |
| system language | Chinese, English, German |
| Display screen | 2.2 TFT LCD screen |
| Operating temperature | -10~50℃ |
| Battery life | 20h |
| Protection level | IP64 |
| Print function | No |
| Machine Weight | 200g |
| Machine size | 70*150*32mm |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Minimum substrate thickness | 0.8mm |
| Test speed | 60 times/minute |
| Probe size | Φ9mm |
| statistical function | Create a new group, open a group, view a group, clear a group, delete a group, and exit a group |
| number of statistical groups | 100 groups |
| Data storage | Article 1 million |
| Other functions | Data download to PC, firmware upgrade, WIFI |
HTechMT CO600FAT1W Coating Thickness Gauge Packing list
host X1, AA battery X2, test piece set X1, zero adjustment plate X1, certificate X1, manual X1, silicone protective cover X1, instrument bag (cloth bag) X1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle characteristics and application of silver Film Thickness Gauge
- Basic principle and application scenario of steel Coating Thickness Gauge


CO600FAT1W