Kedian MCW-2010A eddy current Film Thickness Gauge built-in probe, thickness up to 1200μm
MCW-2010A eddy current Film Thickness Gauge is a new Coating Thickness Gauge of Kedian, with built-in probe, MCW-2010A eddy current Film Thickness Gauge Measurement range is 0~1200um, measurement error is < 3% +/- 1um.
KODIN-
CHINA CTG-802-1500FV cylindrical coating Thickness Gauge, split iron-based large V type, suitable for surface measurement
$ 228.00 -
Defelsko PosiTector 6000 FNGS3 Coating Thickness Gauge 63.5mm Ultra thick probe
$ 2560.00 -
Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
Login -
List Magnetik MEGA-CHEK Pocket FN platings Thickness Gauge
$ 1794.00 -
Defelsko NAS split thin coating probe
$ 1025.00
MCW-2010A Eddy Current Paint Film Thickness Gauge Introduction
MCW-2010A eddy current paint Film Thickness Gauge is a new type of paint Film Thickness Gauge of Kedian Company. It adopts anti-interference technology, high measurement accuracy, digital display, low power consumption, built-in probe full-scale measurement, small model, simple operation, and has the functions of undercurrent indication, statistics, system/zero/two-point calibration, and its performance has reached the professional level of similar instruments in the world.
Features
(1) Measurement: Built-in probe full-scale thickness measurement
(2) Statistics: There are three statistics: average, maximum and minimum
(3) Calibration: Zero point calibration, two-point calibration and system calibration can be carried out
(4) Power level: with under-Voltage display function
(5) Buzzer prompt: There is a buzzer prompt during operation
(6) Shutdown: It has two modes: automatic shutdown and manual shutdown
Product display diagram

KODIN MCW-2010A Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~1200μm |
| margin of error | ±3% |
| Resolution | 1μm |
| Minimum measurement surface | Φ7mm |
| Minimum radius of curvature | Convex 1.5mm; Concave 6mm |
| thinnest substrate | 0.3mm |
| probe | N integrated probe |
| statistical function | MAX Maximum, MIN Minimum, Average |
| icon function | none |
| Power Supply | 2 * 1.5V battery |
| Calibrated Certificate | none |
| system language | Chinese |
| Display screen | 4-Digit LCD digital display |
| supporting software | none |
| Machine Weight | 100G (including battery) |
| Machine size | 115*45*25mm |
| power consumption | Maximum power consumption 110mw |
| Operating temperature | 0~40℃ |
| Voltage prompt | Upper right corner display icon |
| Relative Humidity | ≤90%RH |
KODIN MCW-2010A Thickness Gauge Packing list
host x1, battery x2, standard sample flat sheet box x1, standard iron base x1, aluminum box x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveJB/T 5946-1991
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


MCW-2010A






