TM630 Infrared Thermometer Measurement range -20~320 ℃
TM630 Infrared Thermometer is an economical Infrared Thermometer, TM630 Infrared Thermometer is the preferred product for on-site measurement and home, TM630 Infrared Thermometer Measurement range is -20~320 ℃.
KODIN-
SMART SENSOR AR862A + Handheld Infrared Thermometer Temperature Measurement: -50 ℃~ 900 ℃
$ 135.00 -
SMART SENSOR smart sensor AS862A Infrared Thermometer temperature range -32 ℃~ 330 ℃
$ 111.00 -
SMART SENSOR AR852B + Industrial Infrared Thermometer Range: -50 ℃~ 700 ℃
$ 110.00 -
SMART SENSOR AR300 + Industrial Infrared Thermometer Temperature Range: -32 ℃~ 400 ℃
$ 91.00 -
SMART SENSOR smart sensor AS882A Infrared Thermometer temperature range 200 ℃~ 1850 ℃
$ 257.00
Introducing the TM630 infrared thermometer
The measurement range of the economical TM630 infrared thermometer: -20~320°C, the object distance ratio: 12:1, is a high-quality low-end infrared thermometer with the upper and lower prices on the market.
The TM630 infrared thermometer has a 4-digit backlit LCD display, laser aiming, and auto-shutdown.
The TM630 infrared thermometer is ergonomically designed by dozens of professionals with a compact and smooth appearance.
The TM630 infrared thermometer is the preferred product for on-site measurements and at home.
Application
Compared with traditional temperature measurement equipment, TM-630 infrared Tester has the advantages of convenience, accuracy and safety. Because of these advantages, infrared thermometers can be used in a wide range of applications!
Include:
1. Iron and steel The infrared thermometer is used to continuously measure the entire temperature of the recuperator and the efficiency of the heater. Measure the temperature on both sides of the plate to determine if the heating is uniform. Improve product quality
2. Glass industry: Test the temperature of the furnace to ensure that the temperature of the glass is consistent from edge to edge and that the glass surface is flat. As a result: ● Increase product yield ● Improve process control ● Improve product consistency ● Reduce downtime
3. Plastic industry ● Blown film pressing: accurate temperature test, which can ensure uniform tensile resistance and thickness of the plastic ● Lamination and embossing treatment: use infrared thermometer to monitor the temperature of the film and control the heater4. Heating, Ventilation & Cooling Using an infrared thermometer: ● Scan the room temperature ● Check the temperature of the pipes ● Test the temperature of the boiler and evaluate the boiler performance ● Look at the supply and return air circuits
5. Supermarkets or food processing enterprises Because the storage temperature of refrigerated food is generally thereBelow 4.4°C, deterioration is possible beyond this range. Therefore, it can be easily and quickly checked with an infrared thermometer
6. Other applications include: grain processing, food processing, aquatic product processing, alcoholic beverage production enterprises, inspection and quarantine departments, etc.
Product performance
Product model | TM-630 |
Temperature measurement range | -20~320℃ |
precision | ±2% or ±2 °C |
Distance-to-target ratio | 8:1 |
thermopile | 5~14μm |
Repetition rate | ±1℃ |
resolution | 0.5℃ |
Reaction time | 500ms |
Operating temperature | 0~50℃,10~90%RH |
Emissivity | 0.95 |
Storage temperature | -10~60℃ |
Battery type | 9V(006P,IEC6F22,NEDA16104) |
Exterior dimensions | Height: 180mm Width: 130mm Thickness: 40mm Weight: 195g |
Battery life | 16hrs |
KODIN TM630 Specifications
| LIST | VALUE |
|---|---|
| Temperature Measurement Range | -20~320℃ |
| Accuracy | ±2% |
| Repeatability | ±1℃ |
| object distance ratio | 8:1 |
| emissivity | 0.95 |
| Response time | 500ms |
| Operating temperature | 0~50℃ |
| Storage temperature | -10~60℃ |
| Power Supply | 9V(006P,IEC6F22,NEDA16104) |
| Dimensions | 180*130*40mm |
| thermopile | 5~14μm |
| Resolution | 0.5℃ |
| Battery life | 16hrs |
KODIN TM630 Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Tensile specimen preparation: cutting and handling techniques for samples of different materials
- Universal Testing Machine Selection Budget Planning: Different price models performance differences
- Customized Universal Testing Machine Selection: Which Scenarios Need to Be Customized? Customized Process Detailed Explanation
- Universal Testing Machine Fixture Selection: Fixture type recommendation for different material samples
- Universal Testing Machine Selection Pit Avoidance Guide: Don't Ignore These Parameters
- Low Temperature Universal Testing Machine Selection: Requirements for equipment performance in low temperature environment
- Universal Testing Machine in high temperature environment: high-temperature chamber matching and accuracy control
- Large Industrial Universal Testing Machine Selection: Range, Stability and Durability Considerations
- Small Laboratory Universal Testing Machine Selection: Cost-effective Model Recommendation
- Temperature, Humidity and other environmental factors affect the long-term stability of Universal Testing Machine