HTechMT CO600F2S Coating Thickness Gauge magnetic 5000 μm
HTechMT Thickness Gauge probe CO600F2S is a thickness probe with a range of 5000 μm, accuracy +/- 1~ 3% or 2.5 μm, minimum headroom height 80mm, test radius 5mm, substrate thickness minimum 0.8mm, CO600F2S is a common magnetic probe.
HTechMT-
Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
Login -
Defelsko PosiTector 6000 FNRS3-E Cladding Thickness Gauge
$ 1955.00 -
DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
$ 575.00 -
Germany EPK FN1.6/90 Thickness Gauge probe 90 ° thickness measurement range 0~1600um
$ 2643.00 -
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
$ 389.00
The Thickness Gauge probe core is made of super wear-resistant materials, which greatly improves the service life of the probe and ensures the measurement accuracy and repeatability of the instrument. This design reverses the common defects in the market, such as inaccurate measurement due to core wear, or falling off the inlaid rubera.
Probe number

Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600F2S Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 5000μm |
| margin of error | ±1~3%/2.5μm |
| thinnest substrate | 0.8mm |
| Test environment | Magnetic metal substrate |
| probe | Ordinary probe |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Probe contact surface diameter | 9mm |
HTechMT CO600F2S Coating Thickness Gauge Packing list
Probe X1, test piece X6, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CO600F2S