HTechMT CO600F2H Coating Thickness Gauge high temperature probe magnetic 5000 μm
HTechMT Thickness Gauge probe CO600F2H is a high temperature probe that can measure 250 ℃, thickness measurement range 5000 μm, accuracy +/- 1~ 3% or 20 μm thickness probe, minimum headroom height 80mm, test radius 5mm, substrate thickness minimum 0.8mm, CO600F2H is an ordinary magnetic probe.
HTechMT-
DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
$ 306.00 -
QNix4200/5 magnetic Induction Coating Thickness Gauge 0-5000um
$ 934.00 -
Defelsko FNTS thick coating probe 0~6mm/+/- 1%
$ 1296.00 -
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
$ 259.00 -
LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
$ 547.00
The Thickness Gauge probe core is made of super wear-resistant materials, which greatly improves the service life of the probe and ensures the measurement accuracy and repeatability of the instrument. This design reverses the common defects in the market, such as inaccurate measurement due to core wear, or falling off the inlaid rubera.
Probe number

Executive Standards:ISO 2178/2360/2808、ISO 19840、ASTM B244/B499/D1186/D1400
Probe selection
| shape | Probe model | A | B | C | Range | Accuracy 1 | Minimum headroom | Minimum test radius | Minimum substrate thickness |
![]() | CO600F1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm |
| CO600F2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600F5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.8mm | |
| CO600F1H | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.8mm | |
| CO600F2H | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.8mm | |
| CO600N1S | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 80mm | 5mm | 0.3mm | |
| CO600N2S | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 80mm | 5mm | 0.3mm | |
| CO600N5S | 9 | 40 | 50 | 0.5mm | ± 1-3% or 2.0μm | 80mm | 5mm | 0.3mm | |
![]() | CO600F1R | 9 | 40 | 50 | 1.6mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.8mm |
| CO600F2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.8mm | |
| CO600N1R | 9 | 40 | 50 | 1.5mm | ± 1-3% or 2.5μm | 30mm | 5mm | 0.3mm | |
| CO600N2R | 9 | 40 | 50 | 5.0mm | ± 1-3% or 20μm | 30mm | 5mm | 0.3mm | |
![]() | CO600F3S | 16.5 | 40 | 50 | 13.0mm | ± 1-3% or 50μm | 80mm | 10mm | 1.0mm |
| CO600F4S | 24 | 60 | 50 | 26.0mm | ± 1-3% or 100μm | 120mm | 30mm | 1.0mm |
*High temperature probe temperature is 250°C
HTechMT CO600F2H Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 5000μm |
| margin of error | ±1~3%/±20μm |
| thinnest substrate | 0.8mm |
| Test environment | Magnetic metal substrate |
| probe | Ordinary probe |
| Minimum headroom | 80mm |
| Minimum measurement surface | R5mm |
| Probe contact surface diameter | 9mm |
| Probe contact temperature | Up to 250 ℃ |
HTechMT CO600F2H Coating Thickness Gauge Packing list
Probe X1, test piece X6, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CO600F2H








